Literature DB >> 19812073

Exhaled droplets due to talking and coughing.

Xiaojian Xie1, Yuguo Li, Hequan Sun, Li Liu.   

Abstract

Respiratory infections can be spread via 'contact' with droplets from expiratory activities such as talking, coughing and sneezing, and also from aerosol-generating clinical procedures. Droplet sizes predominately determine the times they can remain airborne, the possibility of spread of infectious diseases and thus the strategies for controlling the infections. While significant inconsistencies exist between the existing measured data on respiratory droplets generated during expiratory activities, a food dye was used in the mouth during measurements of large droplets, which made the expiratory activities 'unnatural'. We carried out a series of experiments using glass slides and a microscope as well as an aerosol spectrometer to measure the number and size of respiratory droplets produced from the mouth of healthy individuals during talking and coughing with and without a food dye. The total mass of respiratory droplets was measured using a mask, plastic bag with tissue and an electronic balance with a high precision. Considerable subject variability was observed and the average size of droplets captured using glass slides and microscope was about 50-100 microm. Smaller droplets were also detected by the aerosol spectrometer. More droplets seemed to be generated when a food dye was used.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19812073      PMCID: PMC2843952          DOI: 10.1098/rsif.2009.0388.focus

Source DB:  PubMed          Journal:  J R Soc Interface        ISSN: 1742-5662            Impact factor:   4.118


  15 in total

1.  The size distribution of droplets in the exhaled breath of healthy human subjects.

Authors:  R S Papineni; F S Rosenthal
Journal:  J Aerosol Med       Date:  1997

2.  The size and the duration of air-carriage of respiratory droplets and droplet-nuclei.

Authors:  J P Duguid
Journal:  J Hyg (Lond)       Date:  1946-09

Review 3.  Droplet fate in indoor environments, or can we prevent the spread of infection?

Authors:  L Morawska
Journal:  Indoor Air       Date:  2006-10       Impact factor: 5.770

4.  Guideline for isolation precautions in hospitals. The Hospital Infection Control Practices Advisory Committee.

Authors:  J S Garner
Journal:  Infect Control Hosp Epidemiol       Date:  1996-01       Impact factor: 3.254

5.  Dispersion of exhaled droplet nuclei in a two-bed hospital ward with three different ventilation systems.

Authors:  H Qian; Y Li; P V Nielsen; C E Hyldgaard; T W Wong; A T Y Chwang
Journal:  Indoor Air       Date:  2006-04       Impact factor: 5.770

6.  Role of air distribution in SARS transmission during the largest nosocomial outbreak in Hong Kong.

Authors:  Y Li; X Huang; I T S Yu; T W Wong; H Qian
Journal:  Indoor Air       Date:  2005-04       Impact factor: 5.770

7.  Cough-generated aerosols of Mycobacterium tuberculosis: a new method to study infectiousness.

Authors:  Kevin P Fennelly; John W Martyny; Kayte E Fulton; Ian M Orme; Donald M Cave; Leonid B Heifets
Journal:  Am J Respir Crit Care Med       Date:  2003-12-04       Impact factor: 21.405

8.  SARS transmission: language and droplet production.

Authors:  Sakae Inouye
Journal:  Lancet       Date:  2003-07-12       Impact factor: 79.321

9.  The numbers and the sites of origin of the droplets expelled during expiratory activities.

Authors:  J P DUGUID
Journal:  Edinb Med J       Date:  1945-11

10.  Toward understanding the risk of secondary airborne infection: emission of respirable pathogens.

Authors:  Mark Nicas; William W Nazaroff; Alan Hubbard
Journal:  J Occup Environ Hyg       Date:  2005-03       Impact factor: 2.155

View more
  147 in total

1.  Role of two-way airflow owing to temperature difference in severe acute respiratory syndrome transmission: revisiting the largest nosocomial severe acute respiratory syndrome outbreak in Hong Kong.

Authors:  Chun Chen; Bin Zhao; Xudong Yang; Yuguo Li
Journal:  J R Soc Interface       Date:  2010-11-10       Impact factor: 4.118

2.  Quantitative assessment of bio-aerosols contamination in indoor air of University dormitory rooms.

Authors:  Samuel Fekadu Hayleeyesus; Amanuel Ejeso; Fikirte Aklilu Derseh
Journal:  Int J Health Sci (Qassim)       Date:  2015-07

3.  Characterizations of particle size distribution of the droplets exhaled by sneeze.

Authors:  Z Y Han; W G Weng; Q Y Huang
Journal:  J R Soc Interface       Date:  2013-09-11       Impact factor: 4.118

Review 4.  Airborne transmission of disease in hospitals.

Authors:  I Eames; J W Tang; Y Li; P Wilson
Journal:  J R Soc Interface       Date:  2009-10-14       Impact factor: 4.118

5.  A pilot study of the noninvasive assessment of the lung microbiota as a potential tool for the early diagnosis of ventilator-associated pneumonia.

Authors:  Addison K May; Jacob S Brady; Joann Romano-Keeler; Wonder P Drake; Patrick R Norris; Judith M Jenkins; Richard J Isaacs; Erik M Boczko
Journal:  Chest       Date:  2015-06       Impact factor: 9.410

Review 6.  Ventilation control for airborne transmission of human exhaled bio-aerosols in buildings.

Authors:  Hua Qian; Xiaohong Zheng
Journal:  J Thorac Dis       Date:  2018-07       Impact factor: 2.895

Review 7.  Skin care: Historical and contemporary views.

Authors:  Khalid M AlGhamdi; Fahad A AlHomoudi; Huma Khurram
Journal:  Saudi Pharm J       Date:  2013-03-14       Impact factor: 4.330

8.  Transmission of pathogen-laden expiratory droplets in a coach bus.

Authors:  Xia Yang; Cuiyun Ou; Hongyu Yang; Li Liu; Tie Song; Min Kang; Hualiang Lin; Jian Hang
Journal:  J Hazard Mater       Date:  2020-04-12       Impact factor: 10.588

9.  Physico-chemical characteristics of evaporating respiratory fluid droplets.

Authors:  Eric P Vejerano; Linsey C Marr
Journal:  J R Soc Interface       Date:  2018-02       Impact factor: 4.118

10.  Aerosol influenza transmission risk contours: a study of humid tropics versus winter temperate zone.

Authors:  Brian P Hanley; Birthe Borup
Journal:  Virol J       Date:  2010-05-14       Impact factor: 4.099

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.