Residential air exchange rates in three major US metropolitan areas: results from the Relationship Among Indoor, Outdoor, and Personal Air Study 1999-2001.

N Yamamoto1, D G Shendell, A M Winer, J Zhang.   

Abstract

UNLABELLED: We report approximately 500 indoor-outdoor air exchange rate (AER) calculations based on measurements conducted in residences in three US metropolitan areas in 1999-2001: Elizabeth, New Jersey; Houston, Texas; and Los Angeles County, California. Overall, a median AER across these urban areas and seasons was 0.71 air changes per hour (ACH, or per hour; n = 509) while median AERs measured in California (n = 182), New Jersey (n = 163), and Texas (n = 164) were 0.87, 0.88, and 0.47 ACH, respectively. In Texas, the measured AERs were lower in the summer cooling season (median = 0.37 ACH) than in the winter heating season (median = 0.63 ACH), likely because of the reported use of room air conditioners as Houston is typically hot and humid during the summer. The measured AERs in California were higher in summer (median = 1.13 ACH) than in winter (median = 0.61 ACH). Because the summer cooling season in Los Angeles County is less humid than in New Jersey or Texas, natural ventilation through open windows and screened doors likely increased measured AER in California study homes. In New Jersey, AER were similar across heating and cooling seasons, although the median AER was relatively lower during the spring. PRACTICAL IMPLICATIONS: Adequate ventilation or air exchange rate (AER) for an indoor environment is important for human health and comfort, and relevant to building design and energy conservation and efficiency considerations. However, residential AER data, especially measured by more accurate non-toxic tracer gas methodologies, are at present quite limited worldwide, and are insufficient to represent the variations across regions and seasons within and between homes, including apartments and condominiums in more densely populated urban areas. The present paper presents quantitative and qualitative data to characterize residential AERs in three US urban areas with different climate attributes.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19874401     DOI: 10.1111/j.1600-0668.2009.00622.x

Source DB:  PubMed          Journal:  Indoor Air        ISSN: 0905-6947            Impact factor:   5.770


  25 in total

1.  Secondhand exposure to vapors from electronic cigarettes.

Authors:  Jan Czogala; Maciej L Goniewicz; Bartlomiej Fidelus; Wioleta Zielinska-Danch; Mark J Travers; Andrzej Sobczak
Journal:  Nicotine Tob Res       Date:  2013-12-11       Impact factor: 4.244

Review 2.  A review of air exchange rate models for air pollution exposure assessments.

Authors:  Michael S Breen; Bradley D Schultz; Michael D Sohn; Thomas Long; John Langstaff; Ronald Williams; Kristin Isaacs; Qing Yu Meng; Casson Stallings; Luther Smith
Journal:  J Expo Sci Environ Epidemiol       Date:  2013-05-29       Impact factor: 5.563

3.  Effects of climate change on residential infiltration and air pollution exposure.

Authors:  Vito Ilacqua; John Dawson; Michael Breen; Sarany Singer; Ashley Berg
Journal:  J Expo Sci Environ Epidemiol       Date:  2015-05-27       Impact factor: 5.563

4.  Thirdhand Smoke: New Evidence, Challenges, and Future Directions.

Authors:  Peyton Jacob; Neal L Benowitz; Hugo Destaillats; Lara Gundel; Bo Hang; Manuela Martins-Green; Georg E Matt; Penelope J E Quintana; Jonathan M Samet; Suzaynn F Schick; Prue Talbot; Noel J Aquilina; Melbourne F Hovell; Jian-Hua Mao; Todd P Whitehead
Journal:  Chem Res Toxicol       Date:  2016-12-21       Impact factor: 3.739

5.  Relationship among environmental quality variables, housing variables, and residential needs: a secondary analysis of the relationship among indoor, outdoor, and personal air (RIOPA) concentrations database.

Authors:  Fausto Garcia; Derek G Shendell; Jaime Madrigano
Journal:  Int J Biometeorol       Date:  2016-08-30       Impact factor: 3.787

6.  Liquid crystal display screens as a source for indoor volatile organic compounds.

Authors:  Qifan Liu; Jonathan P D Abbatt
Journal:  Proc Natl Acad Sci U S A       Date:  2021-06-08       Impact factor: 11.205

7.  Spatiotemporal variability of tetrachloroethylene in residential indoor air due to vapor intrusion: a longitudinal, community-based study.

Authors:  Jill E Johnston; Jacqueline MacDonald Gibson
Journal:  J Expo Sci Environ Epidemiol       Date:  2013-04-03       Impact factor: 5.563

8.  Particle Concentrations and Effectiveness of Free-Standing Air Filters in Bedrooms of Children with Asthma in Detroit, Michigan.

Authors:  Liuliu Du; Stuart Batterman; Edith Parker; Christopher Godwin; Jo-Yu Chin; Ashley O'Toole; Thomas Robins; Wilma Brakefield-Caldwell; Toby Lewis
Journal:  Build Environ       Date:  2011-10       Impact factor: 6.456

9.  Toward refined estimates of ambient PM2.5 exposure: Evaluation of a physical outdoor-to-indoor transport model.

Authors:  Natasha Hodas; Qingyu Meng; Melissa M Lunden; Barbara J Turpin
Journal:  Atmos Environ (1994)       Date:  2014-02-01       Impact factor: 4.798

10.  Evidence of compensation among waterpipe smokers using harm reduction components.

Authors:  Marielle C Brinkman; Hyoshin Kim; Stephanie S Buehler; Anna M Adetona; Sydney M Gordon; Pamela I Clark
Journal:  Tob Control       Date:  2018-10-30       Impact factor: 7.552

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.