Literature DB >> 21728210

Fetal left modified myocardial performance index: technical refinements in obtaining pulsed-Doppler waveforms.

N Meriki1, A Izurieta, A W Welsh.   

Abstract

OBJECTIVE: To assess the influence of machine settings (wall motion filter (WMF), angle of insonation, Doppler aliasing) and phase of valve clicks on repeatability of measurement of the fetal left modified myocardial performance index (Mod-MPI).
METHODS: Fetal left Mod-MPI was evaluated prospectively in 157 morphologically normal fetuses at 19-36 weeks' gestation. In a baseline cohort, a previously published technique and settings were used for measurement of Mod-MPI. In a second cohort, the influence of WMF, angle of insonation, Doppler aliasing and selection of the phase of the valve clicks on repeatability of measurement of Mod-MPI was assessed.
RESULTS: The intraclass correlation coefficient (ICC) for measurement repeatability in the baseline cohort was 0.22. Increase in WMF to 300 Hz or 500 Hz was associated with an increase in ICC to 0.60 and 0.55, respectively. An angle of insonation of < 15° was associated with an increase in ICC to 0.79 and 0.78 at a WMF of 300 and 500 Hz, respectively. A WMF of 300 Hz, angle of insonation of < 15° and absence of aliasing was associated with an increase in ICC to 0.85 and 0.87 at the beginning and peak of the valve click, respectively. Mod-MPI ranged from 0.35 to 0.48. An increase in calculated MPI was associated with increasing WMF, selection of the beginning vs. peak of the valve clicks and increase in angle of insonation. The presence or absence of aliasing had no effect.
CONCLUSIONS: Refinement of machine settings improves repeatability of Mod-MPI, as does selection of the peak of the valve click. We suggest a consensus be reached as to the precise measurement of MPI, but for the moment would suggest: WMF, 300 Hz; angle of insonation, < 15°; avoiding Doppler aliasing; and selection of valve click peak. Systematic variation in measurement of time intervals may be responsible for the widely varying published normal ranges for Mod-MPI.
Copyright © 2012 ISUOG. Published by John Wiley & Sons, Ltd.

Mesh:

Year:  2012        PMID: 21728210     DOI: 10.1002/uog.9090

Source DB:  PubMed          Journal:  Ultrasound Obstet Gynecol        ISSN: 0960-7692            Impact factor:   7.299


  10 in total

1.  Intermediate Diastolic Velocity as a Parameter of Cardiac Dysfunction in Growth-Restricted Fetuses.

Authors:  Xiangna Tang; Edgar Hernandez-Andrade; Hyunyoung Ahn; Maynor Garcia; Homam Saker; Steven J Korzeniewski; Adi L Tarca; Lami Yeo; Sonia S Hassan; Roberto Romero
Journal:  Fetal Diagn Ther       Date:  2015-08-12       Impact factor: 2.587

Review 2.  Fetal programming as a predictor of adult health or disease: the need to reevaluate fetal heart function.

Authors:  Joana O Miranda; Carla Ramalho; Tiago Henriques-Coelho; José Carlos Areias
Journal:  Heart Fail Rev       Date:  2017-11       Impact factor: 4.214

3.  Assessment of the Fetal Myocardial Performance Index in Well-Controlled Gestational Diabetics and to Determine Whether It Is Predictive of Adverse Perinatal Outcome.

Authors:  Ismail Bhorat; Morgan Pillay; Tarylee Reddy
Journal:  Pediatr Cardiol       Date:  2019-07-19       Impact factor: 1.655

4.  Fetal cardiac function: Feasibility in obtaining the right modified myocardial performance index in a single Doppler waveform.

Authors:  Neama Meriki; Alec W Welsh
Journal:  Australas J Ultrasound Med       Date:  2017-02-01

5.  The clinical prognostic significance of myocardial performance index (MPI) in stable placental-mediated disease.

Authors:  I Bhorat; M Pillay; T Reddy
Journal:  Cardiovasc J Afr       Date:  2018-08-15       Impact factor: 1.167

Review 6.  The Fetal Modified Myocardial Performance Index: Is Automation the Future?

Authors:  Priya Maheshwari; Amanda Henry; Alec W Welsh
Journal:  Biomed Res Int       Date:  2015-06-22       Impact factor: 3.411

7.  The short term fetal cardiovascular effects of corticosteroids used in obstetrics.

Authors:  Amanda Henry; Antonia Shand; Alec Welsh
Journal:  Australas J Ultrasound Med       Date:  2015-12-31

8.  The development of, and future for, fetal functional cardiac imaging techniques.

Authors:  Alec Welsh
Journal:  Australas J Ultrasound Med       Date:  2015-12-31

Review 9.  Spectral Doppler, tissue Doppler, and speckle-tracking echocardiography for the evaluation of fetal cardiac function: an update.

Authors:  Alberto Borges Peixoto; Nathalie Jeanne Bravo-Valenzuela; Luciane Alves Rocha; Edward Araujo Júnior
Journal:  Radiol Bras       Date:  2021 Mar-Apr

10.  Reference ranges of fetal heart function using a Modified Myocardial Performance Index: a prospective multicentre, cross-sectional study.

Authors:  Lijuan Sun; Jingjing Wang; Xiaoting Su; Xinlin Chen; Yuqing Zhou; Xiaoming Zhang; Hong Lu; Jianmei Niu; Lan Yu; Congxin Sun; Wenjun Zhang; Jijing Han; Lina Zhang; Zhenna Wang; Peiwen Chen; Tiantian Chen; Hua Hong; Lulu Zhou; Baoying Ye; Wei Guo; Wei Zhao; Na Zhang; Zhen Li; Sheng Zhao; Qingqing Wu; Jiawei Tian; Yuxin Jiang
Journal:  BMJ Open       Date:  2021-07-07       Impact factor: 2.692

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.