Literature DB >> 34233998

Reference ranges of fetal heart function using a Modified Myocardial Performance Index: a prospective multicentre, cross-sectional study.

Lijuan Sun1, Jingjing Wang1, Xiaoting Su2, Xinlin Chen3, Yuqing Zhou4, Xiaoming Zhang5, Hong Lu6, Jianmei Niu7, Lan Yu8, Congxin Sun9, Wenjun Zhang10, Jijing Han1, Lina Zhang1, Zhenna Wang2, Peiwen Chen3, Tiantian Chen4, Hua Hong5, Lulu Zhou6, Baoying Ye7, Wei Guo8, Wei Zhao9, Na Zhang1, Zhen Li1, Sheng Zhao3, Qingqing Wu11, Jiawei Tian12, Yuxin Jiang13.   

Abstract

OBJECTIVES: The primary aim of this study was to establish the normal reference ranges of the fetal left ventricular (LV) Modified Myocardial Performance Index (Mod-MPI). A secondary aim was to evaluate the agreement between manual and automatic measurements for fetal Mod-MPI.
DESIGN: A prospective, multicentre, cross-sectional study. PARTICIPANTS: Normal singleton pregnancies.
METHODS: The LV functions of normal singleton pregnancies were assessed in nine centres covering eight provinces in China using unified ultrasound protocols and settings and standardised measurements by pulsed Doppler at 20-24, 28-32 and 34-38 weeks of gestation. The isovolumetric relaxation time (IRT), isovolumetric contraction time, ejection time (ET) and Mod-MPI were measured both automatically and manually.
RESULTS: This cross-sectional study included 2081 fetuses, and there was a linear correlation between gestational age (GA) and Mod-MPI (0.416+0.001×GA (weeks), p<0.001, r2=0.013), IRT (36.201+0.162× GA (weeks), p<0.001, r2=0.021) and ET (171.418-0.078*GA (weeks), p<0.001, r2=0.002). This finding was verified using longitudinal data in a subgroup of 610 women. The agreement between the manual and automated measurements for Mod-MPI was good.
CONCLUSIONS: We constructed normal reference values of fetal LV Mod-MPI. Automatic measurement can be considered for ease of measurement in view of the good agreement between the automatic and manual values. © Author(s) (or their employer(s)) 2021. Re-use permitted under CC BY-NC. No commercial re-use. See rights and permissions. Published by BMJ.

Entities:  

Keywords:  cardiology; echocardiography; fetal medicine; heart failure; prenatal diagnosis; ultrasonography

Year:  2021        PMID: 34233998      PMCID: PMC8264880          DOI: 10.1136/bmjopen-2021-049640

Source DB:  PubMed          Journal:  BMJ Open        ISSN: 2044-6055            Impact factor:   2.692


This is the only large multicentre prospective study from nine centres covering eight provinces and five geographical divisions in China. The study used standardised measurements and unified ultrasound settings with well-defined inclusion and exclusion criteria. Longitudinal data were used to test and verify the changes in fetal Modified Myocardial Performance Index (Mod-MPI) and time intervals with advanced gestational age. Only three time points (20–24, 28–32 and 34–38 weeks of gestation) were set in consideration that left ventricular Mod-MPI showed a slight increase as pregnancy advanced.

Introduction

The Myocardial Performance Index (MPI or Tei index) is a quantitative tool for evaluating global cardiac function by incorporating the assessment of systolic and diastolic cardiac function. This index was first described in adults by Tei et al1. The modified MPI (Mod-MPI) can be evaluated using aortic and mitral Doppler valve clicks as landmarks to demarcate the time intervals2 after further adjustment. However, the normal reference ranges of fetal Mod-MPI still show wide variation in recent studies.3–14We have analysed the reasons for this, and they are probably due to a lack of a large enough sample size, a lack of standardised measurement techniques of Mod-MPI, heterogeneous study populations and possibly other maternal or fetal characteristics. Recently, Mod-MPI has been reported to be a valuable index for evaluating fetal cardiac function and it has been evaluated as an indicator for predicting pregnancy outcomes in a number of studies.15–23 Evaluation of Mod-MPI depends on comparison to a normal reference ranges, so a large multicentre study using standardised machine settings and techniques with well-defined inclusion and exclusion criteria is still required, which forms the basis of this study. The primary aim of this study was to establish the normal reference ranges of fetal left ventricular (LV) Mod-MPI and time intervals by pulsed Doppler throughout gestation. A secondary aim was to evaluate the agreement between manual and automatic measurements for fetal Mod-MPI. As the placement of callipers on each valve click is highly dependent on operators, it has been suggested that the Auto Mod-MPI system may increase the reliability and reproducibility, but these conclusions have been based on small sample sizes in previous studies.23 24

Methods

Design, settings and participants

This was a multicentre, prospective cross-sectional study (including a subsample of longitudinal data to verify findings from the cross-sectional study) with a large sample size undertaken between 1 August 2015 and 30 June 2019. Nine centres, covering eight provinces in China, participated in the study: Beijing (Beijing Obstetrics and Gynaecology Hospital, Capital Medical University), Hubei (Maternal and Child Health Hospital of Hubei Province), Shandong(Qingdao Women and Children’s Hospital), Inner Mongolia Autonomous Region (Inner Mongolia People’s Hospital), Xinjiang Uygur Autonomous Region (People’s Hospital of Xinjiang Uygur Autonomous Region), Zhejiang (Women’s Hospital School of Medicine Zhejiang University), Shanghai(The International Peace Maternity and Child Health Hospital, School of Medicine, Shanghai Jiao Tong University, and Shanghai Changning Maternity & Infant Health Hospital), and Hebei (Shijiazhuang Obstetrics and Gynaecology Hospital), which are distributed widely innorthern, central, eastern, northwestern and northeastern China. Women were eligible to participate in the cross-sectional study if they had a normal singleton pregnancy. Women then underwent at least one ultrasound scan at 20–24, 28–32, or 34–38 weeks of gestation. A subgroup of women from the cross-sectional study were also invited to take part in the longitudinal verification study and underwent the entire series of four ultrasound examinations at 11–14, 20–24, 28–32, and 34–38 weeks of gestation. At each hospital, we recruited pregnant women with no clinically relevant obstetric, gynaecological or medical history who initiated antenatal care before 14 weeks of gestation. To approach an optimal health standard, inclusion criteria for the study were based on the fetal Growth Longitudinal Study of INTERGROWTH-21st Project,25 with minor modifications of the normal pregnancy conditions, as described in detail in box 1. Aged ≥18 and <35 years. Body mass index ≥18.5 and <30 kg/m2. Singleton pregnancy. A known last menstrual period with regular cycles (defined as 28±7 days) without hormonal contraceptive use, or breast feeding in the 3 months before pregnancy. Natural conception. No relevant medical history, with no need for long-term medication (including fertility treatment and over-the-counter medicines, but excluding routine iron, folate, calcium, iodine or multivitamin supplements). No use of tobacco or recreational drugs such as cannabis in the 3 months before or after becoming pregnant. No heavy alcohol use and caffeine intake(defined as >5 units (50 mL pure alcohol) per week) since becoming pregnant. No more than one miscarriage in the two previous consecutive pregnancies. No previous baby delivered preterm (<37+0 weeks of gestation) or with a birth weight <2500 g or >4000 g. No previous neonatal or fetal death, ectopic pregnancy, previous baby with any congenital malformations, and no evidence in present pregnancy of congenital disease or fetal anomaly. No previous pregnancy affected by pre-eclampsia/eclampsia, haemolytic anaemia, elevated liver function and low platelet count syndrome, gestational diabetes mellitus/ gestational impaired glucose tolerance, a related pregnancy-associated condition. Normal clinical test indexes. Systolic blood pressure <140 mm Hg and diastolic blood pressure <90 mm Hg. Not in an occupation with risk of exposure to chemicals or toxic substances. Early evaluation of gestational age confirmed by ultrasound examination before 14 weeks. Patients were excluded if any abnormal pregnancy-associated condition developed during follow-up evaluation, such as fetal growth restriction, small-for-gestational-age fetus, pre-eclampsia/eclampsia, haemolytic anaemia, elevated liver function and low platelet count syndrome, gestational impaired glucose tolerance or diabetes, intrahepatic cholestasis, miscarriage, stillbirth, fetal structural malformations, chromosomal abnormalities, inflammatory response syndrome, fetal anaemia, low-lying placenta, placental chorioangioma, polyhydramnios or any other fetal or maternal disease conditions throughout pregnancy. All included women were followed up until birth, and all newborns were examined to confirm the absence of any structural anomalies by a postnatal clinical examination. Those with a birth weight <2500 g or >4000 g and premature birth (defined as birth at less than 37+0 weeks of gestation) were further excluded.

Study measurements

Meticulous standardisation of all measurement techniques was implemented across the nine hospitals. All hospitals used a WS80A ultrasound system (Samsung Medison, Korea) with the same settings. All ultrasonographers taking part in this study underwent standardised training, consisting of a clear understanding of the study protocol, training on the use of the machine, standardisation of measurements for the ultrasound parameters, data collection and quality-control measures. Two sets of ultrasonographic images, including the measurements of Mod-MPI and other Doppler indicators and the assessment of fetal growth and development, were handed in by every specially assigned ultrasonographer from nine centres before the beginning of the study. The ultrasonographers were only allowed to participate once the ultrasonographic pictures were examined and approved by the experts organised by the leading centre (Beijing Obstetrics and Gynaecology Hospital, Capital Medical University). The quality-control measures were based on the regular sampling analysis and mid-period checks of the ultrasonographic images from the nine centres. Gestational age (GA) was based on the last menstrual period and confirmed by ultrasound between 9 weeks and 13+6weeks of gestation, provided that the discrepancy was less than 7 days. We then scanned women at 20–24, 28–32 and 34–38 weeks of gestation. The scan consisted of an assessment of fetal growth, the volume of amniotic fluid, the pulsatility index of the umbilical artery, and the fetal anatomy was examined. All ultrasound scans, including measurement of the crown-rump length, biometry and Doppler evaluations, were performed as described by the International Society of Ultrasound in Obstetrics and practice guidelines.26 27 To improve the reproducibility, unified machine settings28 and standardised measurements2 12 of Mod-MPI across the sites were used. Imaging of the heart was performed with a transverse four-chamber view, in an apical projection, and at the point where the opening and closure of the mitral and aortic valves were clearly shown. The Doppler sampling gate was placed at the cross between the inflow and outflow of the left ventricle and included the leaflets of the mitral valve (MV) and aortic valve (AV) with a 3–4 mm gate size4 and an insonation angle of less than 15°. The Doppler sweep velocity was set at 11.88–13.67 cm/s,27 the wall motion filter was set at 100 Hz, and the scale was set at 55 cm/s. Doppler waveforms were obtained during fetal quiescence and after asking the mother to voluntarily suspend respiration. The patients were examined until apical four-chamber views were obtained. We chose the beginning of the valve clicks as the landmark for the measurement period of Mod-MPI to improve reproducibility.12 23 The callipers were placed just before each valve click (figures 1 and 2). The isovolumetric contraction time (ICT) was measured from closure of the MV to opening of the AV, isovolumetric relaxation time (IRT) from closure of the AV to opening of the MV and ejection time (ET) from opening to closure of the AV. For the automated measurement, the operator placed the cursor on the peak of the aortic outflow of a single Doppler waveform and pressed the ‘Set’ key, and the Auto Mod-MPI system automatically placed the callipers at the beginning of each valve click. ICT, IRT, ET and Mod-MPI were then calculated automatically. The Mod-MPI was measured twice automatically (figure 1) and twice manually (figure 2). Finally, the mean of the two automatic measurements and the mean of the two manual measurements for each case were used in the statistical analysis.
Figure 1

Normal Modified Myocardial Performance Index (Mod-MPI) (Tei index) Doppler image with automatic measurement. MCO=mitral valve closing and open time=ICT + IRT+ET. ET, ejection time; ICT, isovolumetric contraction time; IRT, isovolumetric relaxation time.

Figure 2

Normal Modified Myocardial Performance Index (Mod-MPI) (Tei index) Doppler image with manual measurement. MCO=mitral valve closing and open time=ICT + IRT+ET. ET, ejection time; ICT, isovolumetric contraction time; IRT, isovolumetric relaxation time.

Normal Modified Myocardial Performance Index (Mod-MPI) (Tei index) Doppler image with automatic measurement. MCO=mitral valve closing and open time=ICT + IRT+ET. ET, ejection time; ICT, isovolumetric contraction time; IRT, isovolumetric relaxation time. Normal Modified Myocardial Performance Index (Mod-MPI) (Tei index) Doppler image with manual measurement. MCO=mitral valve closing and open time=ICT + IRT+ET. ET, ejection time; ICT, isovolumetric contraction time; IRT, isovolumetric relaxation time.

Follow-up and pregnancy outcome

Pregnant women and their newborns were followed up until after birth. Any antenatal or intrapartum complications were recorded, and outcomes were ascertained, including GA at birth, delivery mode, birth weight, sex, placental weight and Apgar score.

Patient and public involvement

Patients and the public were not involved in the design, conduct, reporting, or dissemination plans of our research.

Statistical analysis

Data were tested for a normal distribution and expressed as the mean±SD. The reference values for the 5th, 10th, 25th, 50th, 75th, 90th and 95th percentiles for three gestational periods (20–24 weeks, 28–32 weeks and 34–38 weeks) were determined. The intraclass correlation coefficient (ICC) was used to test the repeatability of the measurement of manual and automated Mod-MPI. ICC values of less than 0.20 were considered poor; 0.21 to 0.40, fair; 0.41 to 0.60, moderate; 0.61 to 0.80, good; and 0.81 to 1.00, very good or excellent. A trend test using one-way analysis of variance was used to express the correlation between the parameters of the fetal heart function and the GAs. The best-fit regression equation was provided using linear regression models. Agreement between the manual and automated measurements was also assessed using an equivalence test. Equivalence was considered a priori if 90% CIs of the mean of the differences between the paired manual and automated measurements were within 0.01, a clinically small difference.29Data were analysed with SPSS V.23.0 software (IBM) and SAS V.9.4 software (SAS Institute), with statistical significance defined as p<0.05.

Results

Study flow chart and the patient characteristics

In total, 2479 women who met the eligibility criteria were recruited during 11–13+6 weeks of gestation (figure 3). Finally, 2081 fetuses were recruited in a cross-sectional study, including 465 from Beijing Obstetrics and Gynaecology Hospital, Capital Medical University, 297 from Maternal and Child Health Hospital of Hubei Province, 306 from Qingdao Women and Children’s Hospital, 229 from Inner Mongolia People’s Hospital, 109 from People’s Hospital of Xinjiang Uygur Autonomous Region, 164 from Women’s Hospital School of Medicine Zhejiang University, 148 from The International Peace Maternity and Child Health Hospital, School of Medicine, Shanghai Jiao Tong University, 286 from Shanghai Changning Maternity and Infant Health Hospital), and 77 from Shijiazhuang Obstetrics and Gynaecology Hospital. A total of 610 cases were included in the longitudinal analysis as a subgroup to test and verify the changes in fetal Mod-MPI and time intervals with advanced GA. The baseline characteristics and pregnancy outcomes of the study population are described in table 1.
Figure 3

The study flow chart. FGR, fetal growth restriction.

Table 1

Baseline characteristics and pregnancy outcomes of the study population

Pregnancies
Maternal age, years28.6 (2.7)
Maternal height, cm162.0 (4.9)
Maternal weight, kg57.5 (6.3)
Body mass index, kg/m221.9 (2.2)
Nulliparous80%
Ethnicity the Han nationality93.9%
Caesarean section27%
Male sex49%
Birth weight, kg3.4 (0.3)
Birth gestational age, week39.3 (1.1)

Data are mean (SD) or number (%).

Maternal baseline characteristics were measured during 11–13+6 weeks of gestation.

The study flow chart. FGR, fetal growth restriction. Baseline characteristics and pregnancy outcomes of the study population Data are mean (SD) or number (%). Maternal baseline characteristics were measured during 11–13+6 weeks of gestation. The intraobserver and interobserver agreement of manual and automated Mod-MPI are shown in table 2.
Table 2

The intraobserver and interobserver agreement of manual and automated Mod-MPI

ItemNumberManual Mod-MPIAutomated Mod-MPI
ICC
Intraobserver ICC650.9080.914
95% CI0.853 to 0.9430.863 to 0.947
P value<0.001<0.001
Interobserver ICC650.8790.902
95% CI0.809 to 0.9250.845 to 0.939
P value<0.001<0.001

ICC, the intraclass correlation coefficient; Mod-MPI, Modified Myocardial Performance Index.

The intraobserver and interobserver agreement of manual and automated Mod-MPI ICC, the intraclass correlation coefficient; Mod-MPI, Modified Myocardial Performance Index.

Relationship between parameters of fetal heart function and GA

The Mod-MPI, IRT and ET demonstrated linear correlations with GA (p=0.001,<0.001,=0.03, respectively), but no such correlation was seen with ICT (p>0.05). A scatter plot of LV Mod-MPI, IRT and ET based on the cross-sectional data showed progressive changes with advancing gestation (figure 4). The mean Mod-MPI increased slightly from 0.44 to 0.45 (Mod-MPI=0.416+0.001×GA (weeks), p<0.001, r2=0.013). Similarly, the IRT showed a linear increase (IRT=36.201+0.162×GA (weeks), p<0.001, r2=0.021). However, ET demonstrated a linear decrease (ET=171.418–0.078× GA (weeks), p<0.001, r2=0.002).
Figure 4

Plots of LV Mod-MPI, IRT and ET based on the cross-sectional data (2081 cases) with advancing gestational age (GA). p5=5 th centile; p50=median; p95=95 th centile. ET, ejection time; IRT, isovolumetric relaxation time; Mod-MPI, Modified Myocardial Performance Index.

Plots of LV Mod-MPI, IRT and ET based on the cross-sectional data (2081 cases) with advancing gestational age (GA). p5=5 th centile; p50=median; p95=95 th centile. ET, ejection time; IRT, isovolumetric relaxation time; Mod-MPI, Modified Myocardial Performance Index. Verifications for the parametric models of LV Mod-MPI, IRT and ET with advancing GA based on the longitudinal data are shown in figure 5. Similar to the cross-sectional data, the longitudinal study data also showed that Mod-MPI, IRT and ET had a linear correlation with GA (p<0.001,=0.001, 0.002, respectively), but no significant difference was seen for ICT with advancing GA (p>0.05).
Figure 5

The verification of LV Mod-MPI, IRT and ET with advancing gestational age (GA) based on the longitudinal data (610 cases). p5=5 th centile; p50=median; p95=95 th centile. ET, ejection time; IRT, isovolumetric relaxation time; Mod-MPI, Modified Myocardial Performance Index.

The verification of LV Mod-MPI, IRT and ET with advancing gestational age (GA) based on the longitudinal data (610 cases). p5=5 th centile; p50=median; p95=95 th centile. ET, ejection time; IRT, isovolumetric relaxation time; Mod-MPI, Modified Myocardial Performance Index.

Normal reference ranges for the parameters of fetal heart function

The normal reference ranges for LV-Mod-MPI, IRT, ICT and ET based on the cross-sectional data with manual and automatic methods are shown in tables 3–6. The normal reference ranges of fetal left ventricular Mod-MPI based on the cross-sectional data with the manual and automatic measurements Mod-MPI, Modified Myocardial Performance Index. The normal reference ranges of fetal left ventricular IRT based on the cross-sectional data with the manual and automatic measurements IRT, isovolumetric relaxation time. The normal reference ranges of fetal left ventricular ICT based on the cross-sectional data with the manual and automatic measurements ICT, isovolumetric contraction time. The normal reference ranges of fetal left ventricular ET based on the cross-sectional data with the manual and automatic measurements ET, ejection time. Since the inclusion was that women underwent at least one ultrasound scan at 20–24, 28–32 or 34–38 weeks of gestation, the number of patients at each GA was different and less than 2081.

Agreement between the manual and automated measurements of fetal Mod-MPI

Equivalence limits for the differences between paired manual and automated measurements were based on the clinical significance of fetal Mod-MPI. Equivalence was considered if the 90% CI of the mean of the differences between the paired manual and automated measurements was within 0.01. The agreements between the manual and automated measurements obtained at 20–24, 28–32 and 34–38 weeks of gestation were within these limits (table 7).
Table 7

The agreements between the manual and automated measurements of fetal Mod-MPI obtained at 20–24, 28–32, 34–38 weeks of gestation

Weeks of gestationMeanSDLower of 90% CIUpper of 90% CI
20–240.0070.040−0.008−0.005
28–320.0030.040−0.004−0.001
34–380.0040.041−0.006−0.002

Mod-MPI, Modified Myocardial Performance Index.

The agreements between the manual and automated measurements of fetal Mod-MPI obtained at 20–24, 28–32, 34–38 weeks of gestation Mod-MPI, Modified Myocardial Performance Index.

Discussion

The normal reference ranges of fetal LV Mod-MPI by pulsed Doppler were established, and both the cross-sectional and longitudinal data demonstrated a linear correlation between GA and Mod-MPI. In fact, not only previously published normal ranges of fetal Mod-MPI exhibit wide variations among studies but also the changes of fetal LV Mod-MPI with advancing weeks of gestation are conflicting3–13 (table 8). Therefore, it is necessary to provide longitudinal validation of the temporal changes and normal references of fetal LV Mod-MPI to control for confounding factors. The results demonstrated that fetal Mod-MPI in the left ventricle was relatively constant throughout gestation, showing only a slight increase from 20 to 24 weeks (mean, 0.44; 95th percentile, 0.52) to 34–38 weeks (mean, 0.45; 95th percentile, 0.55) as pregnancy advanced. We decided a priori that the normal reference values for fetal LV-Mod-MPI would be produced from the cross-sectional data, as we hypothesised that a larger sample size of cross-sectional data would be more representative than an exclusively longitudinal study design. Prior to this study, the largest study reporting normal ranges of fetal LV Mod-MPI was from a single centre in Spain, based on cross-sectional data from 730 women.12 However, their results showed higher normal references of fetal LV-Mod-MPI, which are not applicable for the Chinese population.
Table 8

Summary of the published normal reference ranges of fetal left ventricle MPI for singleton pregnancies in the second and third trimester in past 20 years

ResearcherYearGA(weeks)NoCountryDesignMPINormal referenceIRTICTET
Hernandez-Andrade et al2200.18–3174USACross-sectional single centreConstant0.53±0.13ConstantConstantConstant
Hernandez-Andrade et al10200719–39557SpainCross-sectionalIncrease95th increase(0.43 to 0.45)IncreaseConstantDecrease
Van Mieghem et al11200920–36117BelgiumProspective cross-sectional single centreConstant0.34±0.05IncreaseNANA
Meriki and Welsh13201218–38318AustraliaProspective longitudinal single centreIncreaseMean increase(0.49 to 0.51)IncreaseConstantDecrease
Cruz-Martínez et al12201211–41730SpainProspective cross-sectional single centreIncrease95th increase(0.51 to 0.78)IncreaseIncrease<30 weeks increase>30 weeks decrease
Ghawi et al6201316–39420USARetrospective cross-sectional single centreConstant0.464±0.08NANANA
Luewan et al8201412–40562ThailandProspective descriptive single centreIncrease95th increase(0.57 to 0.69)NANANA
Bhorat et al7201420–38419South AfricaProspective cross-sectional single centre<26 w constant>26 w decrease95th (0.42 to 0.36)DecreaseConstantConstant
Lee et al4201612–40447KoreaProspective longitudinal single centreIncreaseMean increase(0.44 to 0.56)IncreaseIncrease<27 weeks increase>27 weeks decrease
Nair and Radhakrishnan5201617–37200IndiaProspective cross-sectional single centreConstant0.42±0.03NANANA
MacDonald et al14201927–29 weeks35–37 weeks519AustraliaProspective longitudinal single centreIncrease95th increase(0.63 to 0.75)NANANA
Peixoto et al9201920–36360BrazilProspective cross-sectional two centreIncreaseMean increase(0.44 to 0.47)IncreaseConstantConstant

ET, ejection time; GA, gestational age; ICT, isovolumetric contraction time; IRT, isovolumetric relaxation time; MPI, Myocardial Performance Index; NA, not available.

Summary of the published normal reference ranges of fetal left ventricle MPI for singleton pregnancies in the second and third trimester in past 20 years ET, ejection time; GA, gestational age; ICT, isovolumetric contraction time; IRT, isovolumetric relaxation time; MPI, Myocardial Performance Index; NA, not available. Considering the small change in the time interval can lead to significant alteration in fetal LV Mod-MPI, we further analysed the changes in the time intervals in relation to GA. Throughout gestation, there was a small decrease in ET, while IRT increased slightly. ICT seemed to be constant with advancing GA. Actually, the alterations of time intervals with pregnancy advancement were inconsistent for singleton pregnancies in previous studies during the past 20 years (table 8). There were only three studies with longitudinal data among the twelve studies,4 13 14 while most were cross-sectional or descriptive, as shown in table 8. Both Meriki et al13 and Lee et al4, with longitudinal data, showed that the Mod-MPI and IRT increased with advancing GA. In addition, Meriki et al13 suggested that ICT was constant and ET decreased throughout gestation. These results were similar to our findings. Our results were verified using longitudinal data from 610 women, which showed that these results were reliable. However, the rigorous definition of longitudinal cases that underwent the entire series of (three) ultrasound examinations at 11–14, 20–24, 28–32, and 34–38 weeks of gestation resulted in the sample size being relatively small. We also demonstrated agreement between manual and automated measurements for fetal Mod-MPI. Both the mean and 95% CIs of the parameters (Mod-MPI, IRT, ICT and ET) of fetal heart function were very close using both methods of measurement. It has been previously reported that automation of fetal Mod-MPI shows excellent reproducibility and reduces the subjectivity of operators.23 Our findings suggest that this automation is reproducible and accurate with a large sample size, which means that it is a reliable technique for measuring fetal left Mod-MPI. This may allow for wider clinical application of measurements of fetal Mod-MPI due to its convenience and time savings.

Conclusions

We created normal reference ranges of fetal LV Mod-MPI by pulsed Doppler in a prospective, large, multicentre study using healthy mothers and fetuses. Automated measurement of fetal LV Mod-MPI could be considered for convenience and time savings, as there is good agreement between automated and manual values.
Table 3

The normal reference ranges of fetal left ventricular Mod-MPI based on the cross-sectional data with the manual and automatic measurements

Weeks of gestationNoMeanSDPercentile
5102550759095
20–24 weeks
 Manual17100.440.050.350.370.400.440.480.510.52
 Auto15280.450.050.370.390.420.450.490.520.54
28–32 weeks
 Manual14860.450.050.370.390.420.450.490.510.53
 Auto14750.450.050.370.390.420.450.490.520.53
34–38 weeks
 Manual11780.450.050.370.380.410.450.490.520.55
 Auto10570.460.050.370.400.420.450.490.520.55

Mod-MPI, Modified Myocardial Performance Index.

Table 4

The normal reference ranges of fetal left ventricular IRT based on the cross-sectional data with the manual and automatic measurements

Weeks of gestationNoMeanSDPercentile
5102550759095
20–24 weeks
 Manual171040629333741444749
 Auto152842533363942454850
28–32 weeks
 Manual148641630343842464951
 Auto147542634363942465052
34–38 weeks
 Manual117842729333842465052
 Auto105743634363942475153

IRT, isovolumetric relaxation time.

Table 5

The normal reference ranges of fetal left ventricular ICT based on the cross-sectional data with the manual and automatic measurements

Weeks of gestationNoMeanSDPercentile
5102550759095
20–24 weeks
 Manual171034723252934394245
 Auto152834625273035394345
28–32 weeks
 Manual148635724263035394447
 Auto147534625273034384245
34–38 weeks
 Manual117834822252934384448
 Auto105734624263034394245

ICT, isovolumetric contraction time.

Table 6

The normal reference ranges of fetal left ventricular ET based on the cross-sectional data with the manual and automatic measurements

Weeks of gestationNoMeanSDPercentile
5102550759095
20–24 weeks
 Manual17101709155158163169175182186
 Auto15281709155159164170175181185
28–32 weeks
 Manual148616911153157163169176183188
 Auto147517011152157163169176184189
34–38 weeks
 Manual117816812149153161169177183188
 Auto105716912148154160169178186189

ET, ejection time.

  29 in total

1.  Development of Australian reference ranges for the left fetal modified myocardial performance index and the influence of caliper location on time interval measurement.

Authors:  N Meriki; A W Welsh
Journal:  Fetal Diagn Ther       Date:  2012-06-28       Impact factor: 2.587

2.  A modified myocardial performance (Tei) index based on the use of valve clicks improves reproducibility of fetal left cardiac function assessment.

Authors:  E Hernandez-Andrade; J López-Tenorio; H Figueroa-Diesel; J Sanin-Blair; E Carreras; L Cabero; E Gratacos
Journal:  Ultrasound Obstet Gynecol       Date:  2005-09       Impact factor: 7.299

3.  Fetal left modified myocardial performance index: technical refinements in obtaining pulsed-Doppler waveforms.

Authors:  N Meriki; A Izurieta; A W Welsh
Journal:  Ultrasound Obstet Gynecol       Date:  2012-03-01       Impact factor: 7.299

4.  Gestational age-adjusted trends and reference intervals of the Modified Myocardial Performance Index (Mod-MPI) and its components, with its interpretation in the context of established cardiac physiological principles.

Authors:  Ismail Bhorat; Jayanthilall Bagratee; Tarylee Reddy
Journal:  Prenat Diagn       Date:  2014-06-19       Impact factor: 3.050

5.  Characterizing cardiac dysfunction in fetuses with left congenital diaphragmatic hernia.

Authors:  Mónica Cruz-Lemini; Brenda Valenzuela-Alcaraz; Julio Granados-Montiel; Josep M Martínez; Fátima Crispi; Eduard Gratacós; Rogelio Cruz-Martínez
Journal:  Prenat Diagn       Date:  2018-04-15       Impact factor: 3.050

6.  Assessment of Cardiac Function in Fetuses of Gestational Diabetic Mothers During the Second Trimester.

Authors:  Mehnaz Atiq; Anum Ikram; Batool M Hussain; Bakhtawar Saleem
Journal:  Pediatr Cardiol       Date:  2017-03-24       Impact factor: 1.655

7.  Monitoring intrahepatic cholestasis of pregnancy using the fetal myocardial performance index: a cohort study.

Authors:  A Henry; A W Welsh
Journal:  Ultrasound Obstet Gynecol       Date:  2015-11       Impact factor: 7.299

8.  The objectives, design and implementation of the INTERGROWTH-21st Project.

Authors:  J Villar; D G Altman; M Purwar; J A Noble; H E Knight; P Ruyan; L Cheikh Ismail; F C Barros; A Lambert; A T Papageorghiou; M Carvalho; Y A Jaffer; E Bertino; M G Gravett; Z A Bhutta; S H Kennedy
Journal:  BJOG       Date:  2013-05-17       Impact factor: 6.531

9.  New index of combined systolic and diastolic myocardial performance: a simple and reproducible measure of cardiac function--a study in normals and dilated cardiomyopathy.

Authors:  C Tei; L H Ling; D O Hodge; K R Bailey; J K Oh; R J Rodeheffer; A J Tajik; J B Seward
Journal:  J Cardiol       Date:  1995-12       Impact factor: 3.159

10.  Fetal left ventricular myocardial performance index: Defining normal values for Indian population and a review of literature.

Authors:  Anupama Nair; Sitaraman Radhakrishnan
Journal:  Ann Pediatr Cardiol       Date:  2016 May-Aug
View more
  1 in total

1.  The role of maternal serum catestatin in the evaluation of preeclampsia and fetal cardiac functions

Authors:  Miraç Özalp; Hüseyin Yaman; Ömer Demir; Sümeyye Aytekin Garip; Turhan Aran; Mehmet Armağan Osmanağaoğlu
Journal:  Turk J Obstet Gynecol       Date:  2021-12-24
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.