The human proximal femur behaves linearly elastic up to failure under physiological loading conditions.

Mateusz Maria Juszczyk1, Luca Cristofolini, Marco Viceconti.   

Abstract

It has not been demonstrated whether the human proximal femur behaves linearly elastic when loaded to failure. In the present study we tested to failure 12 cadaveric femurs. Strain was measured (at 5000Hz) on the bone surface with triaxial strain gages (up to 18 on each femur). High-speed videos (up to 18,000frames/s) were taken during the destructive test. To assess the effect of tissue preservation, both fresh-frozen and formalin-fixed specimens were tested. Tests were carried out at two strain-rates covering the physiological range experienced during daily motor tasks. All specimens were broken in only two pieces, with a single fracture surface. The high-speed videos showed that failure occurred as a single abrupt event in less than 0.25ms. In all specimens, fracture started on the lateral side of the neck (tensile stress). The fractured specimens did not show any sign of permanent deformation. The force-displacement curves were highly linear (R(2)>0.98) up to 99% of the fracture force. When the last 1% of the force-displacement curve was included, linearity slightly decreased (minimum R(2)=0.96). Similarly, all force-strain curves were highly linear (R(2)>0.98 up to 99% of the fracture force). The slope of the first part of the force-displacement curve (up to 70% fracture force) differed from the last part of the curve (from 70% to 100% of the fracture force) by less than 17%. Such a difference was comparable to the fluctuations observed between different parts of the curve. Therefore, it can be concluded that the proximal femur has a linear-elastic behavior up to fracture, for physiological strain-rates.
Copyright © 2011 Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Year:  2011        PMID: 21722906     DOI: 10.1016/j.jbiomech.2011.05.038

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  13 in total

Review 1.  Patient-Specific Bone Multiscale Modelling, Fracture Simulation and Risk Analysis-A Survey.

Authors:  Amadeus C S de Alcântara; Israel Assis; Daniel Prada; Konrad Mehle; Stefan Schwan; Lucia Costa-Paiva; Munir S Skaf; Luiz C Wrobel; Paulo Sollero
Journal:  Materials (Basel)       Date:  2019-12-24       Impact factor: 3.623

2.  What ape proximal femora tell us about femoroacetabular impingement: a comparison.

Authors:  Joost T Fikkers; Heinse W Bouma; Stefan F de Boer; Paul A Toogood; Paulien M van Kampen; Tom Hogervorst
Journal:  Clin Orthop Relat Res       Date:  2015-04       Impact factor: 4.176

Review 3.  A biomechanical sorting of clinical risk factors affecting osteoporotic hip fracture.

Authors:  Y Luo
Journal:  Osteoporos Int       Date:  2015-09-11       Impact factor: 4.507

4.  A quasi-brittle continuum damage finite element model of the human proximal femur based on element deletion.

Authors:  Ridha Hambli
Journal:  Med Biol Eng Comput       Date:  2012-11-21       Impact factor: 2.602

5.  Association of incident hip fracture with the estimated femoral strength by finite element analysis of DXA scans in the Osteoporotic Fractures in Men (MrOS) study.

Authors:  L Yang; N Parimi; E S Orwoll; D M Black; J T Schousboe; R Eastell
Journal:  Osteoporos Int       Date:  2017-11-22       Impact factor: 4.507

6.  Study of the significance of parameters and their interaction on assessing femoral fracture risk by quantitative statistical analysis.

Authors:  Rabina Awal; Jalel Ben Hmida; Yunhua Luo; Tanvir Faisal
Journal:  Med Biol Eng Comput       Date:  2022-02-04       Impact factor: 2.602

7.  Experimental Investigation on the Mechanical Behavior of Bovine Bone Using Digital Image Correlation Technique.

Authors:  Yuxi Chen; Diansen Yang; Yongshang Ma; XianJun Tan; Zhan Shi; Taoran Li; Haipeng Si
Journal:  Appl Bionics Biomech       Date:  2015-02-15       Impact factor: 1.781

8.  Physiological joint line total knee arthroplasty designs are especially sensitive to rotational placement - A finite element analysis.

Authors:  Philippe Moewis; Sara Checa; Ines Kutzner; Hagen Hommel; Georg N Duda
Journal:  PLoS One       Date:  2018-02-05       Impact factor: 3.240

9.  Study of DXA-derived lateral-medial cortical bone thickness in assessing hip fracture risk.

Authors:  Yujia Long; William D Leslie; Yunhua Luo
Journal:  Bone Rep       Date:  2015-04-08

10.  Prediction of incident hip fracture with the estimated femoral strength by finite element analysis of DXA Scans in the study of osteoporotic fractures.

Authors:  Lang Yang; Lisa Palermo; Dennis M Black; Richard Eastell
Journal:  J Bone Miner Res       Date:  2014-12       Impact factor: 6.741

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.