Literature DB >> 21704713

Sensitivity and specificity of high-resolution balanced steady-state free precession fMRI at high field of 9.4T.

Sung-Hong Park1, Tae Kim, Ping Wang, Seong-Gi Kim.   

Abstract

Balanced steady-state free precession (bSSFP) is an attractive fMRI method at high fields due to minimal spatial distortion. To examine sensitivity and specificity of bSSFP fMRI at ultrahigh magnetic field of 9.4T, we performed high-resolution pass-band high flip-angle (16°) bSSFP fMRI with four phase cycling (PC) angles at two repetition times (TR) of 10ms and 20ms and conventional gradient-recalled-echo (GRE) fMRI with TR of 20ms on rat brain during forepaw stimulation. The sensitivity of bSSFP fMRI with TR of 20ms was higher than that of GRE fMRI regardless of PC angle. Because of magnetic field inhomogeneity, fMRI foci were changed with PC angle in bSSFP fMRI, which was more prominent when TR was shorter. Within a middle cortical layer region where magnetic field inhomogeneity was relatively small, the homogeneity of bSSFP fMRI signals was higher at shorter TR. Acquisition of baseline transition-band bSSFP images helped to identify pass- and transition-band regions and to understand corresponding bSSFP fMRI signals. Fourier analysis of the multiple PC bSSFP datasets provided echoes of multiple pathways separately, and the main echo component showed lower sensitivity and better homogeneity than the free induction decay component. In summary, pass-band bSSFP techniques would have advantages over GRE-based fMRI in terms of sensitivity, and may be a good choice for fMRI at ultrahigh fields.
Copyright © 2011 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21704713      PMCID: PMC3144319          DOI: 10.1016/j.neuroimage.2011.06.010

Source DB:  PubMed          Journal:  Neuroimage        ISSN: 1053-8119            Impact factor:   6.556


  26 in total

1.  Diffusion-weighted spin-echo fMRI at 9.4 T: microvascular/tissue contribution to BOLD signal changes.

Authors:  S P Lee; A C Silva; K Ugurbil; S G Kim
Journal:  Magn Reson Med       Date:  1999-11       Impact factor: 4.668

2.  Detection of BOLD changes by means of a frequency-sensitive trueFISP technique: preliminary results.

Authors:  K Scheffler; E Seifritz; D Bilecen; R Venkatesan; J Hennig; M Deimling; E M Haacke
Journal:  NMR Biomed       Date:  2001 Nov-Dec       Impact factor: 4.044

3.  Functional brain imaging using a blood oxygenation sensitive steady state.

Authors:  Karla L Miller; Brian A Hargreaves; Jongho Lee; David Ress; R Christopher deCharms; John M Pauly
Journal:  Magn Reson Med       Date:  2003-10       Impact factor: 4.668

4.  Is TrueFISP a gradient-echo or a spin-echo sequence?

Authors:  Klaus Scheffler; Jürgen Hennig
Journal:  Magn Reson Med       Date:  2003-02       Impact factor: 4.668

5.  Dynamic magnetic resonance imaging of human brain activity during primary sensory stimulation.

Authors:  K K Kwong; J W Belliveau; D A Chesler; I E Goldberg; R M Weisskoff; B P Poncelet; D N Kennedy; B E Hoppel; M S Cohen; R Turner
Journal:  Proc Natl Acad Sci U S A       Date:  1992-06-15       Impact factor: 11.205

6.  Time course EPI of human brain function during task activation.

Authors:  P A Bandettini; E C Wong; R S Hinks; R S Tikofsky; J S Hyde
Journal:  Magn Reson Med       Date:  1992-06       Impact factor: 4.668

7.  Motion-insensitive, steady-state free precession imaging.

Authors:  Y Zur; M L Wood; L J Neuringer
Journal:  Magn Reson Med       Date:  1990-12       Impact factor: 4.668

8.  Frequency-dependent neural activity, CBF, and BOLD fMRI to somatosensory stimuli in isoflurane-anesthetized rats.

Authors:  Tae Kim; Kazuto Masamoto; Mitsuhiro Fukuda; Alberto Vazquez; Seong-Gi Kim
Journal:  Neuroimage       Date:  2010-03-27       Impact factor: 6.556

Review 9.  Spatial localization in NMR spectroscopy in vivo.

Authors:  P A Bottomley
Journal:  Ann N Y Acad Sci       Date:  1987       Impact factor: 5.691

10.  Functional brain mapping by blood oxygenation level-dependent contrast magnetic resonance imaging. A comparison of signal characteristics with a biophysical model.

Authors:  S Ogawa; R S Menon; D W Tank; S G Kim; H Merkle; J M Ellermann; K Ugurbil
Journal:  Biophys J       Date:  1993-03       Impact factor: 4.033

View more
  5 in total

1.  High spatial resolution compressed sensing (HSPARSE) functional MRI.

Authors:  Zhongnan Fang; Nguyen Van Le; ManKin Choy; Jin Hyung Lee
Journal:  Magn Reson Med       Date:  2015-10-29       Impact factor: 4.668

2.  Analysis of the BOLD Characteristics in Pass-Band bSSFP fMRI.

Authors:  Taek Soo Kim; Jongho Lee; Jin Hyung Lee; Gary H Glover; John M Pauly
Journal:  Int J Imaging Syst Technol       Date:  2012-03-01       Impact factor: 2.000

Review 3.  FMRI using balanced steady-state free precession (SSFP).

Authors:  Karla L Miller
Journal:  Neuroimage       Date:  2011-10-20       Impact factor: 6.556

Review 4.  Physiological and Functional Magnetic Resonance Imaging Using Balanced Steady-state Free Precession.

Authors:  Sung-Hong Park; Paul Kyu Han; Seung Hong Choi
Journal:  Korean J Radiol       Date:  2015-05-13       Impact factor: 3.500

5.  Compressed Sensing for fMRI: Feasibility Study on the Acceleration of Non-EPI fMRI at 9.4T.

Authors:  Paul Kyu Han; Sung-Hong Park; Seong-Gi Kim; Jong Chul Ye
Journal:  Biomed Res Int       Date:  2015-08-27       Impact factor: 3.411

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.