Literature DB >> 21696652

Comparison of cerebral aneurysm volumes as determined by digitally measured 3D rotational angiography and approximation from three diameters.

A Sadato1, M Hayakawa, T Tanaka, Y Hirose.   

Abstract

This study compared digital measurement of aneurysm volume by 3D rotational angiography (3D-RA) with an approximation technique using three diameters of an aneurysm to re-interpret previously reported optimal packing densities (volume embolization ratio, VER) in coil embolization of intracranial aneurysms. Estimation of the volume of saccular aneurysms is important for calculation of the VER, which is in turn reported to be useful for prediction of coil compaction. The conventional formula for the volume estimation is V=4/3 π(A/2) (B/2) (C/2), where A, B, and C are the aneurysmal height, length, and width measured on 3D-RA image respectively. Using 3D rotational angiography data from 74 aneurysms, the approximated volume generated using the conventional formula was directly compared with the digitally measured volume. The digitally measured volume varied from 0.003 ml to 7.935 ml, and the dome-to-neck ratio (D/N) from 0.79 up to 4.62. We found that the conventional formula almost systematically underestimated the volume by up to 50 %, particularly when the neck was large relative to the dome (D/N<2). On average, digitally measured volume was 1.26~1.29 times larger than the approximated volume obtained using the conventional formula.Conventional 2D angiography based aneurysm volume calculation tends to underestimate an aneurysm volume, so the so-called VER (volume embolization ratio) could be overestimated.

Entities:  

Mesh:

Year:  2011        PMID: 21696652      PMCID: PMC3287265          DOI: 10.1177/159101991101700203

Source DB:  PubMed          Journal:  Interv Neuroradiol        ISSN: 1591-0199            Impact factor:   1.610


  13 in total

1.  Rates of delayed rebleeding from intracranial aneurysms are low after surgical and endovascular treatment.

Authors: 
Journal:  Stroke       Date:  2006-04-20       Impact factor: 7.914

2.  Evaluation of aneurysm stability after endovascular embolization with Guglielmi detachable coils: correlation between long-term stability and volume embolization ratio.

Authors:  Kenji Yagi; Koichi Satoh; Junichiro Satomi; Shunji Matsubara; Shinji Nagahiro
Journal:  Neurol Med Chir (Tokyo)       Date:  2005-11       Impact factor: 1.742

3.  Evaluation of the stability of small ruptured aneurysms with a small neck after embolization with Guglielmi detachable coils: correlation between coil packing ratio and coil compaction.

Authors:  Yutaka Kai; Jun-ichiro Hamada; Motohiro Morioka; Shigetoshi Yano; Jun-ichi Kuratsu
Journal:  Neurosurgery       Date:  2005-04       Impact factor: 4.654

4.  Evaluation of the stability of aneurysms after embolization using detachable coils: correlation between stability of aneurysms and embolized volume of aneurysms.

Authors:  Shinichi Tamatani; Yasushi Ito; Hiroshi Abe; Tetsuo Koike; Shigekazu Takeuchi; Ryuichi Tanaka
Journal:  AJNR Am J Neuroradiol       Date:  2002-05       Impact factor: 3.825

5.  Long-term angiographic follow-up of 169 intracranial berry aneurysms occluded with detachable coils.

Authors:  C Cognard; A Weill; L Spelle; M Piotin; L Castaings; A Rey; J Moret
Journal:  Radiology       Date:  1999-08       Impact factor: 11.105

6.  Endovascular occlusion of intracranial aneurysms with Guglielmi detachable coils: correlation between coil packing density and coil compaction.

Authors:  Y Kawanabe; A Sadato; W Taki; N Hashimoto
Journal:  Acta Neurochir (Wien)       Date:  2001       Impact factor: 2.216

7.  Ellipsoid approximation versus 3D rotational angiography in the volumetric assessment of intracranial aneurysms.

Authors:  M Piotin; B Daghman; C Mounayer; L Spelle; J Moret
Journal:  AJNR Am J Neuroradiol       Date:  2006-04       Impact factor: 3.825

8.  Relation between aneurysm volume, packing, and compaction in 145 cerebral aneurysms treated with coils.

Authors:  Menno Sluzewski; Willem Jan van Rooij; Marian J Slob; Javier Oliván Bescós; Cornelis H Slump; Douwe Wijnalda
Journal:  Radiology       Date:  2004-04-29       Impact factor: 11.105

9.  Long-term angiographic recurrences after selective endovascular treatment of aneurysms with detachable coils.

Authors:  Jean Raymond; François Guilbert; Alain Weill; Stavros A Georganos; Louis Juravsky; Anick Lambert; Julie Lamoureux; Miguel Chagnon; Daniel Roy
Journal:  Stroke       Date:  2003-05-29       Impact factor: 7.914

10.  Guglielmi detachable coil embolization of cerebral aneurysms: 11 years' experience.

Authors:  Yuichi Murayama; Yih Lin Nien; Gary Duckwiler; Y Pierre Gobin; Reza Jahan; John Frazee; Neil Martin; Fernando Viñuela
Journal:  J Neurosurg       Date:  2003-05       Impact factor: 5.115

View more
  6 in total

1.  Use of a new soft and long coil reduces the number of coils to embolize a small aneurysm.

Authors:  Akiyo Sadato; Motoharu Hayakawa; Kazuhide Adachi; Yoko Kato; Yuichi Hirose
Journal:  Interv Neuroradiol       Date:  2015-05-05       Impact factor: 1.610

2.  Endovascular treatment of aneurysms and platinum coil caliber: Study protocol of a randomized, controlled trial.

Authors:  Jimmy Ghostine; Naim Khoury; Francis Cloutier; Marc Kotowski; Jean-Christophe Gentric; André L Batista; Alain Weill; Daniel Roy; Tim E Darsaut; Jean Raymond
Journal:  Interv Neuroradiol       Date:  2016-08-16       Impact factor: 1.610

3.  Effects of anatomic characteristics of aneurysms on packing density in endovascular coil embolization: analysis of a single center's experience.

Authors:  Akiyo Sadato; Kazuhide Adachi; Motoharu Hayakawa; Yoko Kato; Yuichi Hirose
Journal:  Neurosurg Rev       Date:  2015-07-31       Impact factor: 3.042

4.  Volume measurement of the intracranial aneurysm: a discussion and comparison of the alternatives to manual segmentation.

Authors:  Siang-Hua Victor Chan; Kai-Sing Alain Wong; Yat-Ming Peter Woo; Kwong-Yau Chan; Kar-Ming Leung
Journal:  J Cerebrovasc Endovasc Neurosurg       Date:  2014-12-30

5.  Large Residual Volume, Not Low Packing Density, Is the Most Influential Risk Factor for Recanalization after Coil Embolization of Cerebral Aneurysms.

Authors:  Akiyo Sadato; Motoharu Hayakawa; Kazuhide Adachi; Ichiro Nakahara; Yuichi Hirose
Journal:  PLoS One       Date:  2016-05-06       Impact factor: 3.240

6.  Optimal Woven EndoBridge (WEB) Device Size Selection Using Automated Volumetric Software.

Authors:  Sameer Ansari; Cynthia B Zevallos; Mudassir Farooqui; Andres Dajles; Sebastian Schafer; Darko Quispe-Orozco; Alan Mendez-Ruiz; Samir Abdelkarim; Sudeepta Dandapat; Santiago Ortega-Gutierrez
Journal:  Brain Sci       Date:  2021-07-08
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.