Literature DB >> 21695524

Oxygen uptake efficiency plateau: physiology and reference values.

Xing-Guo Sun1, James E Hansen, William W Stringer.   

Abstract

The relationship of oxygen uptake [Formula: see text] to ventilation [Formula: see text], i.e., oxygen uptake efficiency (OUE) is known to differ between normal subjects and patients with congestive heart failure. However, only the oxygen uptake efficiency slope (OUES, i.e., slope of [Formula: see text] has previously been reported. To understand the physiology and to improve the usefulness of OUE in assessing cardiovascular function, we analyzed the complete response pattern of OUE during entire incremental exercise tests and ascertained effect of age, body size, gender, fitness, and ergometer type on exercise OUE to generate reference values in normal healthy subjects. We investigated the effect of age, gender, and fitness on OUE using incremental cardiopulmonary exercise in 474 healthy subjects, age 17-78 years, of which 57 were highly fit. The final methods of OUE analysis were: (1) OUE plateau at the highest values (OUEP), (2) OUE at anaerobic threshold (OUE@AT), and (3) OUES using the entire exercise period. The OUEP and OUE@AT were similar, highly reproducible, less variable than the OUES (p < 0.0001), and unaffected by the study sites or types of ergometry. The resultant prediction equations from 417 normal subjects for men were OUEP (mL/L) = 42.18 - 0.189 × years + 0.036 × cm and OUES [L/min/log(L/min)] = -0.610 - 0.032 × years + 0.023 × cm + 0.008 × kg. For women, OUEP (mL/L) = 39.16 - 0.189 × years + 0.036 × cm and OUES [L/min/log(L/min)] = -1.178 - 0.032 × years + 0.023 × cm + 0.008 × kg. OUE@AT was similar to OUEP. Extreme fitness has a minimal effect on OUEP. OUEP is advantageous, since it measures maximal oxygen extraction from ventilated air but does not require high intensity exercise. The OUEP is a non-invasive parameter dependent only on age, gender, height, and cardiovascular health.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21695524     DOI: 10.1007/s00421-011-2030-0

Source DB:  PubMed          Journal:  Eur J Appl Physiol        ISSN: 1439-6319            Impact factor:   3.078


  39 in total

1.  Ventilatory efficiency during exercise in healthy subjects.

Authors:  Xing-Guo Sun; James E Hansen; Nuria Garatachea; Thomas W Storer; Karlman Wasserman
Journal:  Am J Respir Crit Care Med       Date:  2002-12-01       Impact factor: 21.405

2.  Oxygen uptake efficiency slope in coronary artery disease: clinical use and response to training.

Authors:  J Defoor; D Schepers; T Reybrouck; R Fagard; L Vanhees
Journal:  Int J Sports Med       Date:  2006-09       Impact factor: 3.118

3.  The influence of body mass index on the oxygen uptake efficiency slope in patients with heart failure.

Authors:  Ross Arena; Jonathan Myers; Joshua Abella; Mary Ann Peberdy; Daniel Bensimhon; Paul Chase; Marco Guazzi
Journal:  Int J Cardiol       Date:  2008-01-29       Impact factor: 4.164

4.  Exercise pathophysiology in patients with primary pulmonary hypertension.

Authors:  X G Sun; J E Hansen; R J Oudiz; K Wasserman
Journal:  Circulation       Date:  2001-07-24       Impact factor: 29.690

5.  Robustness of the oxygen uptake efficiency slope to exercise intensity in patients with coronary artery disease.

Authors:  Reizo Baba; Kazuo Tsuyuki; Hiroyoshi Yano; Kenji Ninomiya; Kunio Ebine
Journal:  Nagoya J Med Sci       Date:  2010-02       Impact factor: 1.131

6.  Oscillatory breathing and exercise gas exchange abnormalities prognosticate early mortality and morbidity in heart failure.

Authors:  Xing-Guo Sun; James E Hansen; John F Beshai; Karlman Wasserman
Journal:  J Am Coll Cardiol       Date:  2010-04-27       Impact factor: 24.094

7.  Oxygen uptake kinetics during cardiopulmonary exercise testing and postoperative complications in patients with lung cancer.

Authors:  Erdem Kasikcioglu; Alper Toker; Serhan Tanju; Piyer Arzuman; Abidin Kayserilioglu; Sukru Dilege; Goksel Kalayci
Journal:  Lung Cancer       Date:  2009-01-29       Impact factor: 5.705

8.  Effect of biventricular pacing on the exercise pathophysiology of heart failure.

Authors:  Karlman Wasserman; Xing-Guo Sun; James E Hansen
Journal:  Chest       Date:  2007-05-15       Impact factor: 9.410

9.  Response of the oxygen uptake efficiency slope to exercise training in patients with chronic heart failure.

Authors:  Christophe Van Laethem; Nico Van De Veire; Guy De Backer; Salhi Bihija; Tony Seghers; Dirk Cambier; Marc Vanderheyden; Johan De Sutter
Journal:  Eur J Heart Fail       Date:  2007-03-08       Impact factor: 15.534

10.  Evaluation of fitness level by the oxygen uptake efficiency slope after a short-term intermittent endurance training.

Authors:  L Mourot; S Perrey; N Tordi; J D Rouillon
Journal:  Int J Sports Med       Date:  2004-02       Impact factor: 3.118

View more
  24 in total

1.  Assessing utility of exercise test in determining exercise prescription in adolescent and adult patients with repaired tetralogy of fallot.

Authors:  Ming-Chun Yang; Chun-An Chen; Hsin-Hui Chiu; Jou-Kou Wang; Ming-Tai Lin; Shuenn-Nan Chiu; Chun-Wei Lu; Shu-Chien Huang; Mei-Hwan Wu
Journal:  Heart Vessels       Date:  2016-06-06       Impact factor: 2.037

2.  Determinants of Cardiorespiratory Fitness Following Thoracic Radiotherapy in Lung or Breast Cancer Survivors.

Authors:  Justin M Canada; Cory R Trankle; Salvatore Carbone; Leo F Buckley; Medina de Chazal; Hayley Billingsley; Ronald K Evans; Ryan Garten; Benjamin W Van Tassell; Dinesh Kadariya; Adolfo Mauro; Stefano Toldo; Eleonora Mezzaroma; Ross Arena; William G Hundley; John D Grizzard; Elisabeth Weiss; Antonio Abbate
Journal:  Am J Cardiol       Date:  2019-12-26       Impact factor: 2.778

Review 3.  The Role of Cardiopulmonary Exercise Testing for Decision Making in Patients with Repaired Tetralogy of Fallot.

Authors:  Frederic Dallaire; Rachel M Wald; Ariane Marelli
Journal:  Pediatr Cardiol       Date:  2017-06-16       Impact factor: 1.655

4.  Oxygen uptake efficiency plateau best predicts early death in heart failure.

Authors:  Xing-Guo Sun; James E Hansen; William W Stringer
Journal:  Chest       Date:  2011-10-26       Impact factor: 9.410

5.  Ventilation Limits Aerobic Capacity after Functional Electrical Stimulation Row Training in High Spinal Cord Injury.

Authors:  Shuang Qiu; Saeed Alzhab; Glen Picard; J Andrew Taylor
Journal:  Med Sci Sports Exerc       Date:  2016-06       Impact factor: 5.411

6.  Functional Evaluation in Obese Patients Before and After Sleeve Gastrectomy.

Authors:  Daniel Neunhaeuserer; Andrea Gasperetti; Francesco Savalla; Stefano Gobbo; Valentina Bullo; Marco Bergamin; Mirto Foletto; Roberto Vettor; Marco Zaccaria; Andrea Ermolao
Journal:  Obes Surg       Date:  2017-12       Impact factor: 4.129

7.  Assessing Late Cardiopulmonary Function in Patients with Repaired Tetralogy of Fallot Using Exercise Cardiopulmonary Function Test and Cardiac Magnetic Resonance.

Authors:  Ming-Chun Yang; Chun-An Chen; Hsin-Hui Chiu; Ssu-Yuan Chen; Jou-Kou Wang; Ming-Tai Lin; Shuenn-Nan Chiu; Chun-Wei Lu; Shu-Chien Huang; Mei-Hwan Wu
Journal:  Acta Cardiol Sin       Date:  2015-11       Impact factor: 2.672

8.  Bicycle spiroergometry: comparison of standardized examination protocols for adolescents: is it necessary to define own standard values for each protocol?

Authors:  Jana Windhaber; Monica Steinbauer; Magdalena Holter; Annemarie Wieland; Kristina Kogler; Regina Riedl; Peter Schober; Christoph Castellani; Georg Singer; Holger Till
Journal:  Eur J Appl Physiol       Date:  2021-03-12       Impact factor: 3.078

9.  Oxygen Uptake Efficiency Slope is Strongly Correlated to VO2peak Long-Term After Arterial Switch Operation.

Authors:  Covadonga Terol Espinosa de Los Monteros; Roel L F Van der Palen; Mark G Hazekamp; Lukas Rammeloo; Monique R M Jongbloed; Nico A Blom; Arend D J Ten Harkel
Journal:  Pediatr Cardiol       Date:  2021-02-01       Impact factor: 1.655

10.  A simple new visualization of exercise data discloses pathophysiology and severity of heart failure.

Authors:  James E Hansen; Xing-Guo Sun; William W Stringer
Journal:  J Am Heart Assoc       Date:  2012-06-22       Impact factor: 5.501

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.