Literature DB >> 14986189

Evaluation of fitness level by the oxygen uptake efficiency slope after a short-term intermittent endurance training.

L Mourot1, S Perrey, N Tordi, J D Rouillon.   

Abstract

Several indicators are used as indices of cardiorespiratory reserve. Among them, oxygen uptake (VO(2)) at peak and ventilatory threshold (VAT) levels are the most common used. In the present study, endurance training was used to evaluate and compare the usefulness of a new index, the Oxygen Uptake Efficiency Slope (OUES) as an alternative to the previous ones. Fifteen physical education student women participated in the study (8 as a trained group [T: age (mean +/- SD) 21.9 +/- 3.3 y, height 165.1 +/- 5.5 cm, weight 60.4 +/- 3.3 kg] and 7 as a control group [C: age 21.7 +/- 1.9 y, height 165.4 +/- 7.2 cm, weight 59.6 +/- 8.6 kg]). Before and after 6 weeks of the Square-Wave Endurance Exercise Test (SWEET) training program or daily activities, they performed an incremental test (30 W/3 min) on a cycle ergometer to determined VO(2), power output and parameters associated with breathing efficiency (the respiratory equivalents, and the ventilatory dead space to tidal volume ratio [Vd/Vt]) at peak- and VAT-levels. The slope of the relationship between ventilation and carbon dioxide production was also calculated. OUES, derived from the logarithmic relationship between VO(2) and minute ventilation (V(E)), was determined at 75 % (OUES75), 90 % (OUES90) and 100 % (OUES100) of exercise duration. After endurance training in T, VO(2) and power output were significantly improved at peak- and VAT-levels while all breathing efficiency indices remained unchanged. No changes were observed in C after 6 weeks. Despite significant correlation between OUES values and VO(2) at peak- and VAT-levels, OUES75, OUES90 and OUES100 did not significantly change after endurance training. While VO(2) and power output at peak- and VAT-levels increased in all T, training-induced changes in OUES appeared more variable. We concluded that OUES was not sufficiently sensitive to highlight improvement of cardiorespiratory reserve after endurance training whereas VO(2) at peak and VAT levels did.

Entities:  

Mesh:

Year:  2004        PMID: 14986189     DOI: 10.1055/s-2004-819943

Source DB:  PubMed          Journal:  Int J Sports Med        ISSN: 0172-4622            Impact factor:   3.118


  6 in total

1.  Calculation of oxygen uptake efficiency slope based on heart rate reserve end-points in healthy elderly subjects.

Authors:  Silvia Pogliaghi; Elisa Dussin; Cantor Tarperi; Antonio Cevese; Federico Schena
Journal:  Eur J Appl Physiol       Date:  2007-08-24       Impact factor: 3.078

2.  Oxygen uptake efficiency plateau best predicts early death in heart failure.

Authors:  Xing-Guo Sun; James E Hansen; William W Stringer
Journal:  Chest       Date:  2011-10-26       Impact factor: 9.410

3.  Oxygen uptake efficiency plateau: physiology and reference values.

Authors:  Xing-Guo Sun; James E Hansen; William W Stringer
Journal:  Eur J Appl Physiol       Date:  2011-06-22       Impact factor: 3.078

4.  Influence of Inspiratory Muscle Training on Ventilatory Efficiency and Cycling Performance in Normoxia and Hypoxia.

Authors:  Eduardo Salazar-Martínez; Hannes Gatterer; Martin Burtscher; José Naranjo Orellana; Alfredo Santalla
Journal:  Front Physiol       Date:  2017-03-08       Impact factor: 4.566

5.  Ventilatory efficiency during constant-load test at lactate threshold intensity: Endurance versus resistance exercises.

Authors:  Lluis Albesa-Albiol; Noemí Serra-Payá; María Ana Garnacho-Castaño; Lluis Guirao Cano; Eulogio Pleguezuelos Cobo; José Luis Maté-Muñoz; Manuel V Garnacho-Castaño
Journal:  PLoS One       Date:  2019-05-21       Impact factor: 3.240

6.  Response of the oxygen uptake efficiency slope to exercise training in patients with chronic kidney disease.

Authors:  Thomas J Wilkinson; Emma L Watson; Noemi Vadaszy; Luke A Baker; João L Viana; Alice C Smith
Journal:  Kidney Res Clin Pract       Date:  2020-09-30
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.