Literature DB >> 33712869

Bicycle spiroergometry: comparison of standardized examination protocols for adolescents: is it necessary to define own standard values for each protocol?

Jana Windhaber1, Monica Steinbauer2, Magdalena Holter3, Annemarie Wieland2, Kristina Kogler2, Regina Riedl3, Peter Schober2, Christoph Castellani2, Georg Singer2, Holger Till2.   

Abstract

PURPOSE: To compare performance data of adolescents collected with five different bicycle spiroergometry protocols and to assess the necessity for establishing standard values for each protocol.
METHODS: One-hundred-twenty adolescents completed two bicycle spiroergometries within 14 days. One of the two tests was performed based on our institutional weight-adapted protocol (P0). The other test was performed based on one out of four exercise protocols widely used for children and adolescents (P1, 2, 3 or 4) with 30 persons each. The two tests were performed in a random order. Routine parameters of cardiopulmonary exercise tests (CPET) such as VO2peak, maximum power, O2 pulse, OUES, VE/VCO2 slope as well as ventilatory and lactate thresholds were investigated. Agreement between protocols was evaluated by Bland-Altman analysis, coefficients of variation (CV) and intra-class correlation coefficients (ICC).
RESULTS: None of the CPET parameters were significantly different between P0 and P1, 2, 3 or 4. For most of the parameters, low biases between P0 and P1-P4 were found and 95% confidence intervalls were narrow. CV and ICC values largely corresponded to well-defined analytical goals (CV < 10% and ICC > 0.9). Only maximal power (Pmax) showed differences in size and drift of the bias depending on the length of the step duration of the protocols.
CONCLUSION: Comparability between examination protocols has been shown for CPET parameters independent on step duration. Protocol-dependent standard values do not appear to be necessary. Only Pmax is dependent on the step duration, but in most cases, this has no significant influence on the fitness assessment.

Entities:  

Keywords:  Adolescents; Examination protocols; Lactate threshold; Maximal power; O2 pulse; OUES; Spiroergometry; VO2peak; Ventilatory threshold

Year:  2021        PMID: 33712869     DOI: 10.1007/s00421-021-04601-y

Source DB:  PubMed          Journal:  Eur J Appl Physiol        ISSN: 1439-6319            Impact factor:   3.078


  29 in total

1.  [Bicycle ergometry exercise tests: a comparison between 3 protocols with an increasing load].

Authors:  P Carta; G Aru; M T Barbieri; M Mele
Journal:  Med Lav       Date:  1991 Jan-Feb       Impact factor: 1.275

2.  The effect of stage duration on the calculation of peak VO2 during cycle ergometry.

Authors:  D Bishop; D G Jenkins; L T Mackinnon
Journal:  J Sci Med Sport       Date:  1998-09       Impact factor: 4.319

Review 3.  Statistical methods for assessing measurement error (reliability) in variables relevant to sports medicine.

Authors:  G Atkinson; A M Nevill
Journal:  Sports Med       Date:  1998-10       Impact factor: 11.136

Review 4.  A Systematic Review of Reference Values in Pediatric Cardiopulmonary Exercise Testing.

Authors:  Samuel Blais; Jade Berbari; Francois-Pierre Counil; Frederic Dallaire
Journal:  Pediatr Cardiol       Date:  2015-06-03       Impact factor: 1.655

5.  Reproducibility of the oxygen uptake efficiency slope in normal healthy subjects.

Authors:  R Baba; N Kubo; Y Morotome; S Iwagaki
Journal:  J Sports Med Phys Fitness       Date:  1999-09       Impact factor: 1.637

6.  Role of the oxygen uptake efficiency slope in evaluating exercise tolerance.

Authors:  R Baba; M Nagashima; Y Nagano; M Ikoma; K Nishibata
Journal:  Arch Dis Child       Date:  1999-07       Impact factor: 3.791

7.  Oxygen uptake efficiency slope: a new index of cardiorespiratory functional reserve derived from the relation between oxygen uptake and minute ventilation during incremental exercise.

Authors:  R Baba; M Nagashima; M Goto; Y Nagano; M Yokota; N Tauchi; K Nishibata
Journal:  J Am Coll Cardiol       Date:  1996-11-15       Impact factor: 24.094

8.  Dynamic interactions of gas exchange, body mass, and progressive exercise in children.

Authors:  Dan M Cooper; Szu-Yun Leu; Pietro Galassetti; Shlomit Radom-Aizik
Journal:  Med Sci Sports Exerc       Date:  2014       Impact factor: 5.411

9.  Optimizing the exercise protocol for cardiopulmonary assessment.

Authors:  M J Buchfuhrer; J E Hansen; T E Robinson; D Y Sue; K Wasserman; B J Whipp
Journal:  J Appl Physiol Respir Environ Exerc Physiol       Date:  1983-11

10.  Reproducibility of peak oxygen uptake and other cardiopulmonary exercise testing parameters in patients with heart failure (from the Heart Failure and A Controlled Trial Investigating Outcomes of exercise traiNing).

Authors:  Daniel R Bensimhon; Eric S Leifer; Stephen J Ellis; Jerome L Fleg; Steven J Keteyian; Ileana L Piña; Dalane W Kitzman; Robert S McKelvie; William E Kraus; Daniel E Forman; Andrew J Kao; David J Whellan; Christopher M O'Connor; Stuart D Russell
Journal:  Am J Cardiol       Date:  2008-07-09       Impact factor: 2.778

View more
  1 in total

1.  Features of Metabolic Support of Physical Performance in Highly Trained Cross-Country Skiers of Different Qualifications during Physical Activity at Maximum Load.

Authors:  Olga I Parshukova; Nina G Varlamova; Natalya N Potolitsyna; Aleksandra Y Lyudinina; Evgeny R Bojko
Journal:  Cells       Date:  2021-12-23       Impact factor: 6.600

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.