Literature DB >> 21691610

The influence of individual bone patterns on peri-implant bone loss: preliminary report from a 3-year randomized clinical and histologic trial in patients treated with implants restored with matching-diameter abutments or the platform-switching concept.

Luigi Canullo1, Giuliano Iannello, Werner Götz.   

Abstract

PURPOSE: This study sought to determine whether there was a correlation between bone resorption and individual bone patterns in patients treated with implants restored conventionally or using the platform-switching concept.
MATERIALS AND METHODS: Ten patients (24 implants) were randomly assigned to receive implants with different platform diameters (3.8, 4.3, 4.8, or 5.5 mm), all of which were restored with standard 3.8-mm-diameter abutments. Biopsy specimens were obtained prior to implant placement, and histologic and immunohistochemical analyses were performed. Standardized radiographs were made at each site after implant placement and at 36 months after prosthetic loading and bone levels were determined.
RESULTS: One patient dropped out, resulting in a total of 9 patients and 22 implants. Mean bone resorption was 1.358 mm for non-platform-switched implants; mean resorption was 0.832, 0.486, and 0.375 mm for implant platforms of 4.3, 4.8, and 5.5 mm, respectively. After standardization of peri-implant bone remodeling values, a borderline direct correlation between peri-implant bone changes and levels of biglycans was found. At the same time, a borderline indirect correlation between bone changes and levels of tumor necrosis factor-a was found.
CONCLUSIONS: Within the limit of this study, which was conducted in a small patient sample over a short observation period, an individual resorption trend was detected and paralleled by immunohistochemical findings. Individual local bone structure and quality seemed to be correlated to peri-implant bone resorption. Correlations between biglycan and tumor necrosis factor-a and bone resorption should be confirmed by a larger patient sample.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21691610

Source DB:  PubMed          Journal:  Int J Oral Maxillofac Implants        ISSN: 0882-2786            Impact factor:   2.804


  9 in total

1.  Assessment of lipopolysaccharide microleakage at conical implant-abutment connections.

Authors:  Sönke Harder; Elgar Susanne Quabius; Lars Ossenkop; Matthias Kern
Journal:  Clin Oral Investig       Date:  2011-12-02       Impact factor: 3.573

Review 2.  Bone level changes around platform switching and platform matching implants: a systematic review with meta-analysis.

Authors:  M DI Girolamo; R Calcaterra; R DI Gianfilippo; C Arcuri; L Baggi
Journal:  Oral Implantol (Rome)       Date:  2016-11-13

3.  Stress distribution in the transitional peri-implant bone in a single implant-supported prosthesis with platform-switching under different angulated loads.

Authors:  Ángel Álvarez-Arenal; Luis Segura-Mori; Ignacio Gonzalez-Gonzalez; Hector DeLlanos-Lanchares; Fernando Sanchez-Lasheras; Joseba Ellacuria-Echevarria
Journal:  Odontology       Date:  2016-03-04       Impact factor: 2.634

4.  Influence of platform switching on bone-level alterations: a three-year randomized clinical trial.

Authors:  N Enkling; P Jöhren; J Katsoulis; S Bayer; P-M Jervøe-Storm; R Mericske-Stern; S Jepsen
Journal:  J Dent Res       Date:  2013-10-24       Impact factor: 6.116

5.  Histological examination and clinical evaluation of the jawbone of an adult patient with cleidocranial dysplasia: a case report.

Authors:  Sigmar Schnutenhaus; Ralph G Luthardt; Heike Rudolph; Werner Götz
Journal:  Int J Clin Exp Pathol       Date:  2015-07-01

6.  Multivariate analysis of the influence of peri-implant clinical parameters and local factors on radiographic bone loss in the posterior maxilla: a retrospective study on 277 dental implants.

Authors:  Mariane B Sordi; Vittoria Perrotti; Flavia Iaculli; Keila C R Pereira; Ricardo S Magini; Stefan Renvert; Stefano Antonio Gattone; Adriano Piattelli; Marco A Bianchini
Journal:  Clin Oral Investig       Date:  2020-11-05       Impact factor: 3.573

7.  Current results and trends in platform switching.

Authors:  Hadi Salimi; Omid Savabi; Farahnaz Nejatidanesh
Journal:  Dent Res J (Isfahan)       Date:  2011-12

8.  Correcting loss of a papilla following orthodontic space opening (Atherton´s patch) through implant supported rehabilitation. A case report.

Authors:  Jose Viña; Jose Balaguer; Luis Martorell; Miguel Peñarrocha
Journal:  J Clin Exp Dent       Date:  2014-02-01

9.  Effect of platform switching on crestal bone levels around implants in the posterior mandible: 3 years results from a multicentre randomized clinical trial.

Authors:  Salomão Rocha; Wilfried Wagner; Jörg Wiltfang; Pedro Nicolau; Maximilian Moergel; Ana Messias; Eleonore Behrens; Fernando Guerra
Journal:  J Clin Periodontol       Date:  2016-03-30       Impact factor: 8.728

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.