Literature DB >> 21680125

CT-guided percutaneous lung biopsy: comparison of conventional CT fluoroscopy to CT fluoroscopy with electromagnetic navigation system in 60 consecutive patients.

David Justin Grand1, Michael A Atalay, John J Cronan, William W Mayo-Smith, Damian E Dupuy.   

Abstract

PURPOSE: To determine if use of an electromagnetic navigation system (EMN) decreases radiation dose and procedure time of CT fluoroscopy guided lung biopsy in lesions smaller than 2.5 cm. MATERIALS/
METHODS: 86 consecutive patients with small lung masses (<2.5 cm) were approached. 60 consented and were randomized to undergo biopsy with CT fluoroscopy (CTF) (34 patients) or EMN (26 patients). Technical failure required conversion to CTF in 8/26 EMN patients; 18 patients completed biopsy with EMN. Numerous biopsy parameters were compared as described below.
RESULTS: Average fluoroscopy time using CTF was 28.2s compared to 35.0 s for EMN (p=0.1). Average radiation dose was 117 mGy using CTF and 123 mGy for EMN (p=0.7). Average number of needle repositions was 3.7 for CTF and 4.4 for EMN (p=0.4). Average procedure time was 15 min for CTF and 20 min for EMN (p=0.01). There were 7 pneumothoracesin the CTF group and 6 pneumothoraces in the EMN group (p=0.7). One pneumothorax in the CTF group and 3 pneumothoraces in the EMN group required chest tube placement (p=0.1). One pneumothorax patient in each group required hospital admission. Diagnostic specimens were obtained in 31/34 patients in the CTF group and 22/26 patients in the EMN group (p=0.4).
CONCLUSIONS: EMN was not statistically different than CTF for fluoroscopy time, radiation dose, number of needle repositions, incidence of pneumothorax, need for chest tube, or diagnostic yield. Procedure time was increased with EMN.
Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

Entities:  

Mesh:

Year:  2011        PMID: 21680125     DOI: 10.1016/j.ejrad.2011.05.030

Source DB:  PubMed          Journal:  Eur J Radiol        ISSN: 0720-048X            Impact factor:   3.528


  9 in total

1.  Image-Guided Biopsy in the Era of Personalized Cancer Care: Proceedings from the Society of Interventional Radiology Research Consensus Panel.

Authors:  Alda L Tam; Howard J Lim; Ignacio I Wistuba; Anobel Tamrazi; Michael D Kuo; Etay Ziv; Stephen Wong; Albert J Shih; Robert J Webster; Gregory S Fischer; Sunitha Nagrath; Suzanne E Davis; Sarah B White; Kamran Ahrar
Journal:  J Vasc Interv Radiol       Date:  2015-11-25       Impact factor: 3.464

2.  Percutaneous lung biopsy: comparison between an augmented reality CT navigation system and standard CT-guided technique.

Authors:  R F Grasso; E Faiella; G Luppi; E Schena; F Giurazza; R Del Vescovo; F D'Agostino; R L Cazzato; B Beomonte Zobel
Journal:  Int J Comput Assist Radiol Surg       Date:  2013-02-03       Impact factor: 2.924

3.  Comparison of acquisition and iterative reconstruction parameters in abdominal computed tomography-guided procedures: a phantom study.

Authors:  Julien Frandon; Philippe Akessoul; Aymeric Hamard; Edinaud Bezandry; Romaric Loffroy; Takieddine Addala; Martin M Bertrand; Jean-Paul Beregi; Joël Greffier
Journal:  Quant Imaging Med Surg       Date:  2022-01

4.  The impact of coaxial core biopsy guided by FDG PET/CT in oncological patients.

Authors:  Juliano Julio Cerci; Carlos Cunha Pereira Neto; Cassiano Krauzer; Danielle Giacometti Sakamoto; João Vicente Vitola
Journal:  Eur J Nucl Med Mol Imaging       Date:  2012-10-26       Impact factor: 9.236

5.  Percutaneous lung biopsies: performance of an optical CT-based navigation system with a low-dose protocol.

Authors:  Rosario Francesco Grasso; Roberto Luigi Cazzato; Giacomo Luppi; Francesco D'Agostino; Emiliano Schena; Riccardo Del Vescovo; Francesco Giurazza; Eliodoro Faiella; Bruno Beomonte Zobel
Journal:  Eur Radiol       Date:  2013-06-20       Impact factor: 5.315

6.  Evaluation of the clinical benefit of an electromagnetic navigation system for CT-guided interventional radiology procedures in the thoraco-abdominal region compared with conventional CT guidance (CTNAV II): study protocol for a randomised controlled trial.

Authors:  R C Rouchy; A Moreau-Gaudry; E Chipon; S Aubry; L Pazart; B Lapuyade; M Durand; M Hajjam; S Pottier; B Renard; R Logier; X Orry; A Cherifi; E Quehen; G Kervio; O Favelle; F Patat; E De Kerviler; C Hughes; M Medici; J Ghelfi; A Mounier; I Bricault
Journal:  Trials       Date:  2017-07-06       Impact factor: 2.279

7.  Computer assisted electromagnetic navigation improves accuracy in computed tomography guided interventions: A prospective randomized clinical trial.

Authors:  Pierre Durand; Alexandre Moreau-Gaudry; Anne-Sophie Silvent; Julien Frandon; Emilie Chipon; Maud Médici; Ivan Bricault
Journal:  PLoS One       Date:  2017-03-15       Impact factor: 3.240

8.  Clinical value of an electromagnetic navigation system for CT-guided percutaneous lung biopsy of peripheral lung lesions.

Authors:  Yao Zhang; Haozhe Huang; Shuhui Cao; Jiajun Teng; Yue Wang; Xuxinyi Ling; Yan Zhou; Jianlin Xu; Wentao Li; Hua Zhong
Journal:  J Thorac Dis       Date:  2021-08       Impact factor: 2.895

9.  Efficacy and safety of a new disposable percutaneous positioning device invented to facilitate the precision of percutaneous core needle lung biopsies: a prospective, open and randomized controlled study.

Authors:  Yunhua Xu; Jun Fu; Wenwei Cao; Li Zhu; Yuehui Jin; Qing Yin; Jianding Ye; Haiyan Zhou
Journal:  J Thorac Dis       Date:  2021-08       Impact factor: 2.895

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.