Literature DB >> 2166048

Immune response to polyglycolic acid implants.

S Santavirta1, Y T Konttinen, T Saito, M Grönblad, E Partio, P Kemppinen, P Rokkanen.   

Abstract

Cytological analysis of material aspirated from the effusion which occasionally develops around a polyglycolic acid (PGA) osteosynthesis implant showed a predominance of inflammatory monocytes and in particular lymphocytes. In order to discover whether PGA implants are immunologically inert, density gradient-isolated peripheral blood mononuclear cells were cultured in 0.2 ml of 10% delta FCS-RPMI 1640 culture medium supplemented with 10 mg PGA. Phytohaemagglutinin (PHA) lectin, a purified protein derivate of tuberculin (PPD) antigen and culture medium alone were used as positive and negative controls. We studied lymphocyte activation kinetics on days 0, 1, 3 and 5. Major histocompatibility complex locus II antigen (MHC locus II antigen) and interleukin-2 receptor (IL-2R) expression were analysed using the avidin-biotin-peroxidase complex (ABC) method and lymphocyte DNA synthesis by using 3H-thymidine incorporation and beta-scintillation counting. Especially on culture days 0 and 1, lymphocytes and monocytes were seen by light microscopy to be attached to PGA particles. However, our results show no PGA-induced lymphocyte DNA synthesis, but PGA-induced MHC locus II antigen and IL-2R activation marker expression was seen, greater than in negative controls, but less than that seen in PPD antigen driven lymphocyte response. This suggests that PGA is an immunologically inert implant material, but it does seem to induce inflammatory mononuclear cell migration and adhesion, leading to a slight non-specific lymphocyte activation. This activation is lower than that seen in mitogen and antigen-driven lymphocyte responses.

Entities:  

Mesh:

Substances:

Year:  1990        PMID: 2166048     DOI: 10.1302/0301-620X.72B4.2166048

Source DB:  PubMed          Journal:  J Bone Joint Surg Br        ISSN: 0301-620X


  15 in total

1.  Short-term and long-term effects of orthopedic biodegradable implants.

Authors:  Ami R Amini; James S Wallace; Syam P Nukavarapu
Journal:  J Long Term Eff Med Implants       Date:  2011

2.  Biocompatibility of hydroxyapatite-coated hip prostheses.

Authors:  S Santavirta; D Nordström; P Ylinen; Y T Konttinen; T Silvennoinen; P Rokkanen
Journal:  Arch Orthop Trauma Surg       Date:  1991       Impact factor: 3.067

3.  Local immune inflammatory response to infected total hip and knee replacements.

Authors:  D Nordström; S Santavirta; I Antti-Poika; Y T Konttinen
Journal:  Arch Orthop Trauma Surg       Date:  1994       Impact factor: 3.067

Review 4.  Biodegradable implants in traumatology: a review on the state-of-the-art.

Authors:  G O Hofmann
Journal:  Arch Orthop Trauma Surg       Date:  1995       Impact factor: 3.067

5.  Tissue restoration after implantation of polyglycolide, polydioxanone, polylevolactide, and metallic pins in cortical bone: an experimental study in rabbits.

Authors:  Harri K Pihlajamäki; Sari T Salminen; Olli Tynninen; Ole M Böstman; Outi Laitinen
Journal:  Calcif Tissue Int       Date:  2010-05-22       Impact factor: 4.333

6.  Fibrous wound repair associated with biodegradable poly-L/D-lactide copolymer implants: study of the expression of tenascin and cellular fibronectin.

Authors:  R Kontio; A Salo; R Suuronen; C Lindqvist; J H Meurman; I Virtanen
Journal:  J Mater Sci Mater Med       Date:  1998-10       Impact factor: 3.896

7.  Biocompatibility of solid poly (ortho ester).

Authors:  M Ekholm; A Salo; S Syrjänen; P Laine; C Lindqvist; M Kellomäki; I Virtanen; R Suuronen
Journal:  J Mater Sci Mater Med       Date:  1997-05       Impact factor: 3.896

8.  Tissue reactions of subcutaneously implanted mixture of epsilon-caprolactone-lactide copolymer and tricalcium phosphate. An electron microscopic evaluation in sheep.

Authors:  Marja Ekholm; Jarkko Hietanen; Riitta-Mari Tulamo; Jarkko Muhonen; Christian Lindqvist; Minna Kellomäki; Riitta Suuronen
Journal:  J Mater Sci Mater Med       Date:  2003-10       Impact factor: 3.896

9.  Bone response to polymers based on poly-lactic acid and having different degradation times.

Authors:  A Merolli; C Gabbi; A Cacchioli; L Ragionieri; L Caruso; L Giannotta; P Tranquilli Leali
Journal:  J Mater Sci Mater Med       Date:  2001-09       Impact factor: 3.896

10.  [Absorbable rods and screws: a new method of fixation for fractures of the olecranon].

Authors:  E K Partio; E Hirvensalo; O Böstman; H Pätiälä; S Vainionpää; R Vihtonen; P Helevirta; P Törmälä; P Rokkanen
Journal:  Int Orthop       Date:  1992       Impact factor: 3.075

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.