Literature DB >> 1428337

[Absorbable rods and screws: a new method of fixation for fractures of the olecranon].

E K Partio1, E Hirvensalo, O Böstman, H Pätiälä, S Vainionpää, R Vihtonen, P Helevirta, P Törmälä, P Rokkanen.   

Abstract

Between April 1986 and July 1990 fractures of the olecranon in 41 adult patients were treated by fixation with absorbable rods (20 patients) and screws (21 patients) of self-reinforced polyglycolide (SR-PGA), 3.2 mm in diameter and 20-70 mm in length. Patients were followed up for a mean time of 2 years 7 months (range 1 year to 4 years 6 months). After reduction of the fracture, channels were drilled from the proximal fragment through the cortex of the distal fragment and the fractures were fixed with absorbable rods or screws. By one year from follow-up maintenance of an anatomical reduction of the fracture was seen in 34 patients. Failure of fixation requiring a second operation occurred in 2 cases. In all cases functional recovery was at least satisfactory. Sinus formation as a sign of transient tissue reaction was observed in 3 cases, but did not influence the healing of the fractures or the functional recovery. The results in patients treated with rods or screws was similar. Absorbable screws combined with small rods and absorbable sutures allow treatment of +ore severe fractures of the olecranon than do rods alone.

Entities:  

Mesh:

Substances:

Year:  1992        PMID: 1428337     DOI: 10.1007/bf00182705

Source DB:  PubMed          Journal:  Int Orthop        ISSN: 0341-2695            Impact factor:   3.075


  12 in total

1.  Faltin lecture 1989. Absorbable implants in the fixation of fractures.

Authors:  P Rokkanen
Journal:  Ann Chir Gynaecol       Date:  1990

2.  Transphyseal fracture fixation using biodegradable pins.

Authors:  O Böstman; E A Mäkelä; P Törmälä; P Rokkanen
Journal:  J Bone Joint Surg Br       Date:  1989-08

3.  Healing of physeal fracture after fixation with biodegradable self-reinforced polyglycolic acid pins. An experimental study on growing rabbits.

Authors:  E A Mäkelä; S Vainionpää; K Vihtonen; M Mero; J Laiho; P Törmälä; P Rokkanen
Journal:  Clin Mater       Date:  1990

4.  [Fractures of the olecranon].

Authors:  H Bracq
Journal:  Rev Chir Orthop Reparatrice Appar Mot       Date:  1987

5.  Displaced olecranon fractures in adults. Biomechanical analysis of fixation methods.

Authors:  D F Murphy; W B Greene; J A Gilbert; T B Dameron
Journal:  Clin Orthop Relat Res       Date:  1987-11       Impact factor: 4.176

6.  Fracture of the olecranon: a problem of management.

Authors:  A C Rettig; T R Waugh; P M Evanski
Journal:  J Trauma       Date:  1979-01

7.  A preliminary study of the osteogenic potential of a biodegradable alloplastic-osteoinductive alloimplant.

Authors:  J P Schmitz; J O Hollinger
Journal:  Clin Orthop Relat Res       Date:  1988-12       Impact factor: 4.176

8.  Immune response to polyglycolic acid implants.

Authors:  S Santavirta; Y T Konttinen; T Saito; M Grönblad; E Partio; P Kemppinen; P Rokkanen
Journal:  J Bone Joint Surg Br       Date:  1990-07

9.  Complications of tension-band wiring of olecranon fractures.

Authors:  D Macko; R M Szabo
Journal:  J Bone Joint Surg Am       Date:  1985-12       Impact factor: 5.284

10.  Self-reinforced absorbable screws in the fixation of displaced ankle fractures: a prospective clinical study of 152 patients.

Authors:  E K Partio; O Böstman; E Hirvensalo; S Vainionpää; K Vihtonen; H Pätiälä; P Törmälä; P Rokkanen
Journal:  J Orthop Trauma       Date:  1992       Impact factor: 2.512

View more
  2 in total

Review 1.  Surgical interventions for treating fractures of the olecranon in adults.

Authors:  Hosam E Matar; Amjid A Ali; Simon Buckley; Nicholas I Garlick; Henry D Atkinson
Journal:  Cochrane Database Syst Rev       Date:  2014-11-26

2.  Biodegradable wire fixation in olecranon and patella fractures combined with biodegradable screws or plugs and compared with metallic fixation.

Authors:  T Juutilainen; H Pätiälä; P Rokkanen; P Törmälä
Journal:  Arch Orthop Trauma Surg       Date:  1995       Impact factor: 3.067

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.