Literature DB >> 21657122

Full arch scans: conventional versus digital impressions--an in-vitro study.

A Ender1, A Mehl.   

Abstract

The digital intraoral impression has become a central part of the CAD/CAM technique. The objective of the present study was to compare the accuracy (trueness and precision) of digital impressions of the full arch with that of conventional impressions on the in-vitro model. For this purpose, a master model was acquired with a new reference scanning process, the measuring trueness of which was +/- 4.1 microm and the precision +/- 2.5 microm. On the one hand, conventional impressions and then plaster models (n = 5) were produced from this master model, and on the other hand, digital impressions were made with the Cerec AC Bluecam and the Lava COS system (each n = 5). The plaster models were also scanned with the reference scanner. The available data records were superimposed and the differences determined. The deviation from the master model defines the trueness of the impression method. The deviations of the models among one another demonstrate the precision of the method. The trueness of the impressions was 55 +/- 21.8 microm in the conventional impression group, for digital impressions with Cerec Bluecam it was 49 +/- 14.2 microm and for digital impressions with Lava COS 40.3 +/- 14.1 microm. The precision was 61.3 +/- 17.9 microm for conventional impression with Impregum, 30.9 +/- 7.1 microm for digital impression with the Cerec Bluecam and 60.1 +/- 31.3 microm for digital impression with Lava COS. These in-vitro results show that accuracy of the digital impression is similar to that of the conventional impression. These results will have to be confirmed in further clinical studies.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21657122

Source DB:  PubMed          Journal:  Int J Comput Dent        ISSN: 1463-4201            Impact factor:   1.883


  61 in total

1.  A new method for the evaluation of the accuracy of full-arch digital impressions in vitro.

Authors:  Jan-Frederik Güth; Daniel Edelhoff; Josef Schweiger; Christine Keul
Journal:  Clin Oral Investig       Date:  2015-10-10       Impact factor: 3.573

2.  Accuracy of full-arch digital impressions: an in vitro and in vivo comparison.

Authors:  Christine Keul; Jan-Frederik Güth
Journal:  Clin Oral Investig       Date:  2019-05-27       Impact factor: 3.573

3.  Marginal and internal fit of four-unit zirconia fixed dental prostheses based on digital and conventional impression techniques.

Authors:  Júnio S Almeida e Silva; Kurt Erdelt; Daniel Edelhoff; Élito Araújo; Michael Stimmelmayr; Luiz Clovis Cardoso Vieira; Jan-Frederik Güth
Journal:  Clin Oral Investig       Date:  2013-05-29       Impact factor: 3.573

4.  Accuracy of full-arch scans using intraoral scanners.

Authors:  Sebastian B M Patzelt; Archontia Emmanouilidi; Susanne Stampf; Joerg R Strub; Wael Att
Journal:  Clin Oral Investig       Date:  2013-11-17       Impact factor: 3.573

Review 5.  Revolutionizing restorative dentistry: an overview.

Authors:  D R Prithviraj; Harleen Kaur Bhalla; Richa Vashisht; K Sounderraj; Shruthi Prithvi
Journal:  J Indian Prosthodont Soc       Date:  2014-02-05

6.  Influence of the three-dimensional printing technique and printing layer thickness on model accuracy.

Authors:  Zhe-Chen Zhang; Pei-Lun Li; Feng-Ting Chu; Gang Shen
Journal:  J Orofac Orthop       Date:  2019-06-06       Impact factor: 1.938

7.  Precision of guided scanning procedures for full-arch digital impressions in vivo.

Authors:  Moritz Zimmermann; Christina Koller; Moritz Rumetsch; Andreas Ender; Albert Mehl
Journal:  J Orofac Orthop       Date:  2017-07-21       Impact factor: 1.938

8.  Digital implant planning and guided implant surgery - workflow and reliability.

Authors:  O Schubert; J Schweiger; M Stimmelmayr; E Nold; J-F Güth
Journal:  Br Dent J       Date:  2019-01-25       Impact factor: 1.626

9.  Accuracy of digital and conventional impression techniques and workflow.

Authors:  Paul Seelbach; Cora Brueckel; Bernd Wöstmann
Journal:  Clin Oral Investig       Date:  2012-10-21       Impact factor: 3.573

10.  The clinical accuracy of single crowns exclusively fabricated by digital workflow--the comparison of two systems.

Authors:  Petya K Brawek; Stefan Wolfart; Lutz Endres; Armin Kirsten; Sven Reich
Journal:  Clin Oral Investig       Date:  2013-01-31       Impact factor: 3.573

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.