This paper describes a new microfluidic platform for screening drugs and their dose response on the locomotion behavior of free living nematodes and parasitic nematodes. The system offers a higher sensitivity drug screening chip which employs a combination of existing and newly developed methods. Real-time observation of the entire drug application process (i.e. the innate pre-exposure locomotion, the transient response during drug exposure and the time-resolved, post-exposure behavior) at a single worm resolution is made possible. The chip enables the monitoring of four nematode parameters (number of worms responsive, number of worms leaving the drug well, average worm velocity and time until unresponsiveness). Each parameter generates an inherently different dose response; allowing for a higher resolution when screening for resistance. We expect this worm chip could be used as a robust cross species, cross drug platform. Existing nematode motility and migration assays do not offer this level of sophistication. The device comprises two principal components: behavioral microchannels to study nematode motility and a drug well for administering the dose and observing drug effects as a function of exposure time. The drug screening experiment can be described by three main steps: (i) 'pre-exposure study'- worms are inserted into the behavioral channels and their locomotion is characterized, (ii) 'dose exposure'- worms are guided from the behavioral microchannels into the drug well and held for a predefined time, during which time their transient response to the dose is characterized and (iii) 'post-exposure study'- worms are guided back into the behavioral microchannels where their locomotion (i.e. their time-resolved response to the dose) is characterized and compared to pre-exposure motility. The direction of nematodes' movement is reliably controlled by the application of an electric field within a defined range. Control experiments (e.g. in the absence of any drug) confirm that the applied electric fields do not affect the worms' motility or viability. We demonstrate the workability of the microfluidic platform on free living Caenorhabditis elegans (wild-type N2 and levamisole resistant ZZ15 lev-8) and parasitic Oesophagotomum dentatum (levamisole-sensitive, SENS and levamisole-resistant, LEVR) using levamisole (a well-studied anthelmintic) as the test drug. The proposed scheme of drug screening on a microfluidic device is expected to significantly improve the resolution, sensitivity and data throughput of in vivo testing, while offering new details on the transient and time-resolved exposure effects of new and existing anthelmintics.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21647497      PMCID: PMC3645292          DOI: 10.1039/c1lc20170k

Source DB:  PubMed          Journal:  Lab Chip        ISSN: 1473-0189            Impact factor:   6.799


  50 in total

1.  Step-response analysis of chemotaxis in Caenorhabditis elegans.

Authors:  Adam C Miller; Tod R Thiele; Serge Faumont; Marin L Moravec; Shawn R Lockery
Journal:  J Neurosci       Date:  2005-03-30       Impact factor: 6.167

2.  Chemosensory neurons with overlapping functions direct chemotaxis to multiple chemicals in C. elegans.

Authors:  C I Bargmann; H R Horvitz
Journal:  Neuron       Date:  1991-11       Impact factor: 17.173

3.  An automated tracking system for Caenorhabditis elegans locomotor behavior and circadian studies application.

Authors:  Sergio H Simonetta; Diego A Golombek
Journal:  J Neurosci Methods       Date:  2007-01-04       Impact factor: 2.390

4.  The fundamental role of pirouettes in Caenorhabditis elegans chemotaxis.

Authors:  J T Pierce-Shimomura; T M Morse; S R Lockery
Journal:  J Neurosci       Date:  1999-11-01       Impact factor: 6.167

5.  Pathogenic bacteria induce aversive olfactory learning in Caenorhabditis elegans.

Authors:  Yun Zhang; Hang Lu; Cornelia I Bargmann
Journal:  Nature       Date:  2005-11-10       Impact factor: 49.962

6.  Characterization of polydimethylsiloxane (PDMS) properties for biomedical micro/nanosystems.

Authors:  Alvaro Mata; Aaron J Fleischman; Shuvo Roy
Journal:  Biomed Microdevices       Date:  2005-12       Impact factor: 2.838

7.  Neurons regulating the duration of forward locomotion in Caenorhabditis elegans.

Authors:  Tokumitsu Wakabayashi; Izumi Kitagawa; Ryuzo Shingai
Journal:  Neurosci Res       Date:  2004-09       Impact factor: 3.304

8.  Assays to detect beta-tubulin codon 200 polymorphism in Trichuris trichiura and Ascaris lumbricoides.

Authors:  Aissatou Diawara; Lesley J Drake; Richard R Suswillo; Jimmy Kihara; Donald A P Bundy; Marilyn E Scott; Carli Halpenny; J Russell Stothard; Roger K Prichard
Journal:  PLoS Negl Trop Dis       Date:  2009-03-24

9.  Nemo: a computational tool for analyzing nematode locomotion.

Authors:  George D Tsibidis; Nektarios Tavernarakis
Journal:  BMC Neurosci       Date:  2007-10-17       Impact factor: 3.288

10.  The Parallel Worm Tracker: a platform for measuring average speed and drug-induced paralysis in nematodes.

Authors:  Daniel Ramot; Brandon E Johnson; Tommie L Berry; Lucinda Carnell; Miriam B Goodman
Journal:  PLoS One       Date:  2008-05-21       Impact factor: 3.240

View more
  30 in total

1.  Microfluidic chamber arrays for whole-organism behavior-based chemical screening.

Authors:  Kwanghun Chung; Mei Zhan; Jagan Srinivasan; Paul W Sternberg; Emily Gong; Frank C Schroeder; Hang Lu
Journal:  Lab Chip       Date:  2011-09-20       Impact factor: 6.799

2.  Microfluidic assembly kit based on laser-cut building blocks for education and fast prototyping.

Authors:  Lukas C Gerber; Honesty Kim; Ingmar H Riedel-Kruse
Journal:  Biomicrofluidics       Date:  2015-11-18       Impact factor: 2.800

3.  A microfluidic device for whole-animal drug screening using electrophysiological measures in the nematode C. elegans.

Authors:  Shawn R Lockery; S Elizabeth Hulme; William M Roberts; Kristin J Robinson; Anna Laromaine; Theodore H Lindsay; George M Whitesides; Janis C Weeks
Journal:  Lab Chip       Date:  2012-05-15       Impact factor: 6.799

4.  Amplitude-modulated sinusoidal microchannels for observing adaptability in C. elegans locomotion.

Authors:  Archana Parashar; Roy Lycke; John A Carr; Santosh Pandey
Journal:  Biomicrofluidics       Date:  2011-06-17       Impact factor: 2.800

5.  Microfluidic platform integrated with worm-counting setup for assessing manganese toxicity.

Authors:  Beibei Zhang; Yinbao Li; Qidi He; Jun Qin; Yanyan Yu; Xinchun Li; Lin Zhang; Meicun Yao; Junshan Liu; Zuanguang Chen
Journal:  Biomicrofluidics       Date:  2014-09-24       Impact factor: 2.800

Review 6.  Micro total analysis systems: fundamental advances and applications in the laboratory, clinic, and field.

Authors:  Michelle L Kovarik; Douglas M Ornoff; Adam T Melvin; Nicholas C Dobes; Yuli Wang; Alexandra J Dickinson; Philip C Gach; Pavak K Shah; Nancy L Allbritton
Journal:  Anal Chem       Date:  2012-12-04       Impact factor: 6.986

7.  Multiparameter behavioral analyses provide insights to mechanisms of cyanide resistance in Caenorhabditis elegans.

Authors:  Jenifer N Saldanha; Archana Parashar; Santosh Pandey; Jo Anne Powell-Coffman
Journal:  Toxicol Sci       Date:  2013-06-26       Impact factor: 4.849

Review 8.  Ion channels and receptor as targets for the control of parasitic nematodes.

Authors:  Adrian J Wolstenholme
Journal:  Int J Parasitol Drugs Drug Resist       Date:  2011-10-14       Impact factor: 4.077

9.  An integrated platform enabling optogenetic illumination of Caenorhabditis elegans neurons and muscular force measurement in microstructured environments.

Authors:  Zhichang Qiu; Long Tu; Liang Huang; Taoyuanmin Zhu; Volker Nock; Enchao Yu; Xiao Liu; Wenhui Wang
Journal:  Biomicrofluidics       Date:  2015-02-19       Impact factor: 2.800

10.  Micro-electro-fluidic grids for nematodes: a lens-less, image-sensor-less approach for on-chip tracking of nematode locomotion.

Authors:  Peng Liu; Richard J Martin; Liang Dong
Journal:  Lab Chip       Date:  2013-02-21       Impact factor: 6.799

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.