Literature DB >> 23254956

Micro-electro-fluidic grids for nematodes: a lens-less, image-sensor-less approach for on-chip tracking of nematode locomotion.

Peng Liu1, Richard J Martin, Liang Dong.   

Abstract

This paper reports on the development of a lens-less and image-sensor-less micro-electro-fluidic (MEF) approach for real-time monitoring of the locomotion of microscopic nematodes. The technology showed promise for overcoming the constraint of the limited field of view of conventional optical microscopy, with relatively low cost, good spatial resolution, and high portability. The core of the device was microelectrode grids formed by orthogonally arranging two identical arrays of microelectrode lines. The two microelectrode arrays were spaced by a microfluidic chamber containing a liquid medium of interest. As a nematode (e.g., Caenorhabditis elegans) moved inside the chamber, the invasion of part of its body into some intersection regions between the microelectrodes caused changes in the electrical resistance of these intersection regions. The worm's presence at, or absence from, a detection unit was determined by a comparison between the measured resistance variation of this unit and a pre-defined threshold resistance variation. An electronic readout circuit was designed to address all the detection units and read out their individual electrical resistances. By this means, it was possible to obtain the electrical resistance profile of the whole MEF grid, and thus, the physical pattern of the swimming nematode. We studied the influence of a worm's body on the resistance of an addressed unit. We also investigated how the full-frame scanning and readout rates of the electronic circuit and the dimensions of a detection unit posed an impact on the spatial resolution of the reconstructed images of the nematode. Other important issues, such as the manufacturing-induced initial non-uniformity of the grids and the electrotaxic behaviour of nematodes, were also studied. A drug resistance screening experiment was conducted by using the grids with a good resolution of 30 × 30 μm(2). The phenotypic differences in the locomotion behaviours (e.g., moving speed and oscillation frequency extracted from the reconstructed images with the help of software) between the wild-type (N2) and mutant (lev-8) C. elegans worms in response to different doses of the anthelmintic drug, levamisole, were investigated. The locomotive parameters obtained by the MEF grids agreed well with those obtained by optical microscopy. Therefore, this technology will benefit whole-animal assays by providing a structurally simple, potentially cost-effective device capable of tracking the movement and phenotypes of important nematodes in various microenvironments.

Entities:  

Mesh:

Year:  2013        PMID: 23254956      PMCID: PMC3587735          DOI: 10.1039/c2lc41174a

Source DB:  PubMed          Journal:  Lab Chip        ISSN: 1473-0189            Impact factor:   6.799


  54 in total

Review 1.  Control and detection of chemical reactions in microfluidic systems.

Authors:  Andrew J DeMello
Journal:  Nature       Date:  2006-07-27       Impact factor: 49.962

2.  An automated tracking system for Caenorhabditis elegans locomotor behavior and circadian studies application.

Authors:  Sergio H Simonetta; Diego A Golombek
Journal:  J Neurosci Methods       Date:  2007-01-04       Impact factor: 2.390

3.  Ultra wide-field lens-free monitoring of cells on-chip.

Authors:  Aydogan Ozcan; Utkan Demirci
Journal:  Lab Chip       Date:  2007-11-01       Impact factor: 6.799

4.  Femtosecond laser nanoaxotomy lab-on-a-chip for in vivo nerve regeneration studies.

Authors:  Samuel X Guo; Frederic Bourgeois; Trushal Chokshi; Nicholas J Durr; Massimo A Hilliard; Nikos Chronis; Adela Ben-Yakar
Journal:  Nat Methods       Date:  2008-04-13       Impact factor: 28.547

Review 5.  Optical imaging techniques in microfluidics and their applications.

Authors:  Jigang Wu; Guoan Zheng; Lap Man Lee
Journal:  Lab Chip       Date:  2012-10-07       Impact factor: 6.799

Review 6.  Microfluidics-enabled phenotyping, imaging, and screening of multicellular organisms.

Authors:  Matthew M Crane; Kwanghun Chung; Jeffrey Stirman; Hang Lu
Journal:  Lab Chip       Date:  2010-04-09       Impact factor: 6.799

7.  Pathogenic bacteria induce aversive olfactory learning in Caenorhabditis elegans.

Authors:  Yun Zhang; Hang Lu; Cornelia I Bargmann
Journal:  Nature       Date:  2005-11-10       Impact factor: 49.962

Review 8.  Finding function in novel targets: C. elegans as a model organism.

Authors:  Titus Kaletta; Michael O Hengartner
Journal:  Nat Rev Drug Discov       Date:  2006-05       Impact factor: 84.694

9.  SU-8 force sensing pillar arrays for biological measurements.

Authors:  Joseph C Doll; Nahid Harjee; Nathan Klejwa; Ronald Kwon; Sarah M Coulthard; Bryan Petzold; Miriam B Goodman; Beth L Pruitt
Journal:  Lab Chip       Date:  2009-02-27       Impact factor: 6.799

10.  The Parallel Worm Tracker: a platform for measuring average speed and drug-induced paralysis in nematodes.

Authors:  Daniel Ramot; Brandon E Johnson; Tommie L Berry; Lucinda Carnell; Miriam B Goodman
Journal:  PLoS One       Date:  2008-05-21       Impact factor: 3.240

View more
  8 in total

1.  High-throughput, motility-based sorter for microswimmers such as C. elegans.

Authors:  Jinzhou Yuan; Jessie Zhou; David M Raizen; Haim H Bau
Journal:  Lab Chip       Date:  2015-05-26       Impact factor: 6.799

2.  Microfluidic platform integrated with worm-counting setup for assessing manganese toxicity.

Authors:  Beibei Zhang; Yinbao Li; Qidi He; Jun Qin; Yanyan Yu; Xinchun Li; Lin Zhang; Meicun Yao; Junshan Liu; Zuanguang Chen
Journal:  Biomicrofluidics       Date:  2014-09-24       Impact factor: 2.800

3.  Microfluidic chip for automated screening of carbon dioxide conditions for microalgal cell growth.

Authors:  Zhen Xu; Yingjun Wang; Yuncong Chen; Martin H Spalding; Liang Dong
Journal:  Biomicrofluidics       Date:  2017-11-22       Impact factor: 2.800

4.  A formative evaluation of two evidence-based psychotherapies for PTSD in VA residential treatment programs.

Authors:  Joan M Cook; Casey O'Donnell; Stephanie Dinnen; Nancy Bernardy; Robert Rosenheck; Rani Hoff
Journal:  J Trauma Stress       Date:  2013-02

5.  3D arrays for high throughput assay of cell migration and electrotaxis.

Authors:  Sanjun Zhao; Runchi Gao; Peter N Devreotes; Alex Mogilner; Min Zhao
Journal:  Cell Biol Int       Date:  2013-05-07       Impact factor: 3.612

6.  FIM imaging and FIMtrack: two new tools allowing high-throughput and cost effective locomotion analysis.

Authors:  Benjamin Risse; Nils Otto; Dimitri Berh; Xiaoyi Jiang; Christian Klämbt
Journal:  J Vis Exp       Date:  2014-12-24       Impact factor: 1.355

7.  An integrated in vitro imaging platform for characterizing filarial parasite behavior within a multicellular microenvironment.

Authors:  Timothy Kassis; Henry M Skelton; Iris M Lu; Andrew R Moorhead; J Brandon Dixon
Journal:  PLoS Negl Trop Dis       Date:  2014-11-20

8.  Anthelmintic drug actions in resistant and susceptible C. elegans revealed by electrophysiological recordings in a multichannel microfluidic device.

Authors:  Janis C Weeks; Kristin J Robinson; Shawn R Lockery; William M Roberts
Journal:  Int J Parasitol Drugs Drug Resist       Date:  2018-10-30       Impact factor: 4.077

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.