Literature DB >> 21640877

Are orthodontic distalizers reinforced with the temporary skeletal anchorage devices effective?

Piotr Fudalej1, Joanna Antoszewska.   

Abstract

INTRODUCTION: Our objective was to perform a systematic review of studies pertaining to the distalization of teeth with appliances reinforced with temporary skeletal anchorage devices.
METHODS: PubMed, Embase, Cochrane Central Register of Controlled Trials, Web of Knowledge, Ovid, and Scopus were searched until the second week of August 2010 to identify all articles reporting on the use of orthodontic implants or miniplates in distalization of teeth. The quality of the relevant studies was ranked on an 11-point scale, from low to high quality.
RESULTS: Twelve relevant articles were identified. The distal movement of the maxillary molars was from 3.3 to 6.4 mm; the concomitant molar distal tipping was from 0.80° to 12.20°. The maxillary incisors remained stable during molar distalization. The assessment of study quality showed that 8 studies were of low and 4 of medium quality.
CONCLUSIONS: Molar distalizers reinforced with the temporary skeletal anchorage devices seem to effectively move molars distally without unwanted mesial incisor tipping. Because of the lack of high-quality studies, however, the findings of this study should be interpreted with caution.
Copyright © 2011 American Association of Orthodontists. Published by Mosby, Inc. All rights reserved.

Mesh:

Substances:

Year:  2011        PMID: 21640877     DOI: 10.1016/j.ajodo.2011.01.019

Source DB:  PubMed          Journal:  Am J Orthod Dentofacial Orthop        ISSN: 0889-5406            Impact factor:   2.650


  13 in total

1.  Upper molar distalization with skeletally anchored TopJet appliance.

Authors:  Bernhard C Pseiner; Anne Wunderlich; Josef W Freudenthaler
Journal:  J Orofac Orthop       Date:  2014-01-19       Impact factor: 1.938

2.  Evaluation of the effects of the hybrid Pendulum in comparison with the conventional Pendulum appliance.

Authors:  Erdal Bozkaya; Tuba Tortop; Sema Yüksel; Emine Kaygısız
Journal:  Angle Orthod       Date:  2019-10-23       Impact factor: 2.079

3.  Treatment efficiency of mini-implant-borne distalization depending on age and second-molar eruption.

Authors:  M Nienkemper; B Wilmes; A Pauls; S Yamaguchi; B Ludwig; D Drescher
Journal:  J Orofac Orthop       Date:  2014-03-02       Impact factor: 1.938

4.  Comparison of two implant-supported molar distalization systems.

Authors:  Cagla Sar; Burcak Kaya; Omur Ozsoy; Ayca Arman Özcirpici
Journal:  Angle Orthod       Date:  2012-10-29       Impact factor: 2.079

5.  Maxillary molar distalization with MGBM-system in class II malocclusion.

Authors:  Giuliano Maino; Lisa Mariani; Ida Bozzo; Giovanna Maino; Alberto Caprioglio
Journal:  J Orthod Sci       Date:  2013-07

6.  Skeletal versus conventional intraoral anchorage for the treatment of class II malocclusion: dentoalveolar and skeletal effects.

Authors:  Lisa Mariani; Giuliano Maino; Alberto Caprioglio
Journal:  Prog Orthod       Date:  2014-07-30       Impact factor: 2.750

7.  Comparative evaluation of molar distalization therapy with erupted second molar: Segmented versus Quad Pendulum appliance.

Authors:  Alberto Caprioglio; Mauro Cozzani; Mattia Fontana
Journal:  Prog Orthod       Date:  2014-08-06       Impact factor: 2.750

8.  Bilateral en-masse distalization of maxillary posterior teeth with skeletal anchorage: a case report.

Authors:  Saeed Noorollahian; Shiva Alavi; Farinaz Shirban
Journal:  Dental Press J Orthod       Date:  2016-06

9.  Cone-beam computed tomography-guided three-dimensional evaluation of treatment effectiveness of the Frog appliance.

Authors:  Mujia Li; Xiaoxia Su; Yang Li; Xianglin Li; Xinqin Si
Journal:  Korean J Orthod       Date:  2019-05-21       Impact factor: 1.372

10.  A three-dimensional finite element analysis of molar distalization with a palatal plate, pendulum, and headgear according to molar eruption stage.

Authors:  Ju-Man Kang; Jae Hyun Park; Mohamed Bayome; Moonbee Oh; Chong Ook Park; Yoon-Ah Kook; Sung-Seo Mo
Journal:  Korean J Orthod       Date:  2016-09-19       Impact factor: 1.372