Literature DB >> 21639522

Vacuum compatible sample positioning device for matrix assisted laser desorption∕ionization Fourier transform ion cyclotron resonance mass spectrometry imaging.

Konstantin Aizikov1, Donald F Smith, David A Chargin, Sergei Ivanov, Tzu-Yung Lin, Ron M A Heeren, Peter B O'Connor.   

Abstract

The high mass accuracy and resolving power of Fourier transform ion cyclotron resonance mass spectrometers (FT-ICR MS) make them ideal mass detectors for mass spectrometry imaging (MSI), promising to provide unmatched molecular resolution capabilities. The intrinsic low tolerance of FT-ICR MS to RF interference, however, along with typically vertical positioning of the sample, and MSI acquisition speed requirements present numerous engineering challenges in creating robotics capable of achieving the spatial resolution to match. This work discusses a two-dimensional positioning stage designed to address these issues. The stage is capable of operating in ∼1 × 10(-8) mbar vacuum. The range of motion is set to 100 mm × 100 mm to accommodate large samples, while the positioning accuracy is demonstrated to be less than 0.4 micron in both directions under vertical load over the entire range. This device was integrated into three different matrix assisted laser desorption∕ionization (MALDI) FT-ICR instruments and showed no detectable RF noise. The "oversampling" MALDI-MSI experiments, under which the sample is completely ablated at each position, followed by the target movement of the distance smaller than the laser beam, conducted on the custom-built 7T FT-ICR MS demonstrate the stability and positional accuracy of the stage robotics which delivers high spatial resolution mass spectral images at a fraction of the laser spot diameter.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21639522      PMCID: PMC3117896          DOI: 10.1063/1.3594099

Source DB:  PubMed          Journal:  Rev Sci Instrum        ISSN: 0034-6748            Impact factor:   1.523


  28 in total

1.  Heterogeneity within MALDI samples as revealed by mass spectrometric imaging.

Authors:  R W Garden; J V Sweedler
Journal:  Anal Chem       Date:  2000-01-01       Impact factor: 6.986

2.  Broad-band ion accumulation with an internal source MALDI-FTICR-MS.

Authors:  T H Mize; I J Amster
Journal:  Anal Chem       Date:  2000-12-15       Impact factor: 6.986

3.  Internal calibration on adjacent samples (InCAS) with Fourier transform mass spectrometry.

Authors:  P B O'Connor; C E Costello
Journal:  Anal Chem       Date:  2000-12-15       Impact factor: 6.986

4.  Attomole peptide analysis by high-pressure matrix-assisted laser desorption/ionization Fourier transform mass spectrometry.

Authors:  Susanne C Moyer; Bogdan A Budnik; Jason L Pittman; Catherine E Costello; Peter B O'Connor
Journal:  Anal Chem       Date:  2003-12-01       Impact factor: 6.986

5.  A high pressure matrix-assisted laser desorption ion source for Fourier transform mass spectrometry designed to accommodate large targets with diverse surfaces.

Authors:  Peter B O'Connor; Bogdan A Budnik; Vera B Ivleva; Parminder Kaur; Susanne C Moyer; Jason L Pittman; Catherine E Costello
Journal:  J Am Soc Mass Spectrom       Date:  2004-01       Impact factor: 3.109

6.  Direct analysis of drug candidates in tissue by matrix-assisted laser desorption/ionization mass spectrometry.

Authors:  Michelle L Reyzer; Yunsheng Hsieh; Kwokei Ng; Walter A Korfmacher; Richard M Caprioli
Journal:  J Mass Spectrom       Date:  2003-10       Impact factor: 1.982

Review 7.  Tissue profiling by mass spectrometry: a review of methodology and applications.

Authors:  Robert L Caldwell; Richard M Caprioli
Journal:  Mol Cell Proteomics       Date:  2005-01-26       Impact factor: 5.911

Review 8.  Examples of Fourier transform ion cyclotron resonance mass spectrometry developments: from ion physics to remote access biochemical mass spectrometry.

Authors:  A Römpp; I M Taban; R Mihalca; M C Duursma; T H Mize; L A McDonnel; R M A Heeren
Journal:  Eur J Mass Spectrom (Chichester)       Date:  2005       Impact factor: 1.067

9.  Changes of phospholipid composition within the dystrophic muscle by matrix-assisted laser desorption/ionization mass spectrometry and mass spectrometry imaging.

Authors:  David Touboul; Hélène Piednoël; Vincent Voisin; Sabine De La Porte; Alain Brunelle; Frédéric Halgand; Olivier Laprévote
Journal:  Eur J Mass Spectrom (Chichester)       Date:  2004       Impact factor: 1.067

10.  Coupling thin-layer chromatography with vibrational cooling matrix-assisted laser desorption/ionization Fourier transform mass spectrometry for the analysis of ganglioside mixtures.

Authors:  Vera B Ivleva; Yuri N Elkin; Bogdan A Budnik; Susanne C Moyer; Peter B O'Connor; Catherine E Costello
Journal:  Anal Chem       Date:  2004-11-01       Impact factor: 6.986

View more
  2 in total

1.  A gain and bandwidth enhanced transimpedance preamplifier for Fourier-transform ion cyclotron resonance mass spectrometry.

Authors:  Tzu-Yung Lin; Roger J Green; Peter B O'Connor
Journal:  Rev Sci Instrum       Date:  2011-12       Impact factor: 1.523

Review 2.  Mapping of phospholipids by MALDI imaging (MALDI-MSI): realities and expectations.

Authors:  Louis J Sparvero; Andrew A Amoscato; C Edward Dixon; Joseph B Long; Patrick M Kochanek; Bruce R Pitt; Hülya Bayir; Valerian E Kagan
Journal:  Chem Phys Lipids       Date:  2012-06-09       Impact factor: 3.329

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.