Literature DB >> 21624844

Monte Carlo derivation of AAPM TG-43 dosimetric parameters for GZP6 Co-60 HDR sources.

Sanaz Hariri Tabrizi1, Alireza Kamali Asl, Zohreh Azma.   

Abstract

Cobalt 60 source is generally available on high dose rate (HDR) afterloading equipment especially for treatment of gynecological lesions. The GZP6 remote afterloader (Nuclear Power Institute of China) utilizes (60)Co sources for treatment of intracavitary and intraluminal malignancies. In this study, the AAPM TG-43 dosimetric parameters of three sources in GZP6 system have been studied using MCNP4C Monte Carlo (MC) code; and the results are compared with other available (60)Co HDR sources. The presented parameters consist of air kerma strength, dose rate constant, radial dose function and anisotropy function. They show less than 1% uncertainty. The TG-43 based dosimetry data can be used not only to validate the dedicated treatment planning software (TPS), but also to introduce new complementary software to enhance the system performance in gynecological treatments. Copyright Â
© 2011 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21624844     DOI: 10.1016/j.ejmp.2011.04.004

Source DB:  PubMed          Journal:  Phys Med        ISSN: 1120-1797            Impact factor:   2.685


  4 in total

1.  A retrospective analysis of rectal and bladder dose for gynecological brachytherapy treatments with GZP6 HDR afterloading system.

Authors:  Mohammad Taghi Bahreyni Toossi; Mahdi Ghorbani; Yasha Makhdoumi; Mojtaba Taheri; Fatemeh Homaee Shandiz; Siavash Zahed Anaraki; Ali Soleimani Meigooni
Journal:  Rep Pract Oncol Radiother       Date:  2012-07-15

2.  Dosimetric study of GZP6 60 Co high dose rate brachytherapy source.

Authors:  Qin Lei; Anjian Xu; Chengjun Gou; Yumei Wen; Donglin He; Junxiang Wu; Qing Hou; Zhangwen Wu
Journal:  J Appl Clin Med Phys       Date:  2018-05-28       Impact factor: 2.102

3.  Monte Carlo dosimetric study of the Flexisource Co-60 high dose rate source.

Authors:  Javier Vijande; Domingo Granero; Jose Perez-Calatayud; Facundo Ballester
Journal:  J Contemp Brachytherapy       Date:  2012-03-30

4.  Evaluation of BEBIG HDR (60)Co system for non-invasive image-guided breast brachytherapy.

Authors:  Mehdi Zehtabian; Sedigheh Sina; Mark J Rivard; Ali S Meigooni
Journal:  J Contemp Brachytherapy       Date:  2015-12-30
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.