MicroCT morphometry analysis of mouse cancellous bone: intra- and inter-system reproducibility.

K Verdelis1, L Lukashova, E Atti, P Mayer-Kuckuk, M G E Peterson, S Tetradis, A L Boskey, M C H van der Meulen.   

Abstract

The agreement between measurements and the relative performance reproducibility among different microcomputed tomography (microCT) systems, especially at voxel sizes close to the limit of the instruments, is not known. To compare this reproducibility 3D morphometric analyses of mouse cancellous bone from distal femoral epiphyses were performed using three different ex vivo microCT systems: GE eXplore Locus SP, Scanco μCT35 and Skyscan 1172. Scans were completed in triplicate at 12 μm and 8 μm voxel sizes and morphometry measurements, from which relative values and dependence on voxel size were examined. Global and individual visually assessed thresholds were compared. Variability from repeated scans at 12 μm voxel size was also examined. Bone volume fraction and trabecular separation values were similar, while values for relative bone surface, trabecular thickness and number varied significantly across the three systems. The greatest differences were measured in trabecular thickness (up to 236%) and number (up to 218%). The relative dependence of measurements on voxel size was highly variable for the trabecular number (from 0% to 20% relative difference between measurements from 12 μm and 8 μm voxel size scans, depending on the system). The intra-system reproducibility of all trabecular measurements was also highly variable across the systems and improved for BV/TV in all the systems when a smaller voxel size was used. It improved using a smaller voxel size in all the other parameters examined for the Scanco system, but not consistently so for the GE or the Skyscan system. Our results indicate trabecular morphometry measurements should not be directly compared across microCT systems. In addition, the conditions, including voxel size, for trabecular morphometry studies in mouse bone should be chosen based on the specific microCT system and the measurements of main interest.
Copyright © 2011 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2011        PMID: 21621659      PMCID: PMC3391301          DOI: 10.1016/j.bone.2011.05.013

Source DB:  PubMed          Journal:  Bone        ISSN: 1873-2763            Impact factor:   4.398


  35 in total

1.  Evaluation of a microcomputed tomography system to study trabecular bone structure.

Authors:  J L Kuhn; S A Goldstein; L A Feldkamp; R W Goulet; G Jesion
Journal:  J Orthop Res       Date:  1990-11       Impact factor: 3.494

2.  Intrinsic mechanical properties of trabecular calcaneus determined by finite-element models using 3D synchrotron microtomography.

Authors:  H Follet; F Peyrin; E Vidal-Salle; A Bonnassie; C Rumelhart; P J Meunier
Journal:  J Biomech       Date:  2006-12-29       Impact factor: 2.712

3.  Correlations between grey-level variations in 2D projection images (TBS) and 3D microarchitecture: applications in the study of human trabecular bone microarchitecture.

Authors:  Laurent Pothuaud; Pascal Carceller; Didier Hans
Journal:  Bone       Date:  2008-01-29       Impact factor: 4.398

4.  Three-Dimensional X-ray Microtomography.

Authors:  B P Flannery; H W Deckman; W G Roberge; K L D'Amico
Journal:  Science       Date:  1987-09-18       Impact factor: 47.728

5.  The relationship between three-dimensional connectivity and the elastic properties of trabecular bone.

Authors:  J H Kinney; A J Ladd
Journal:  J Bone Miner Res       Date:  1998-05       Impact factor: 6.741

6.  In vivo cyclic axial compression affects bone healing in the mouse tibia.

Authors:  Michael J Gardner; Marjolein C H van der Meulen; Demetris Demetrakopoulos; Timothy M Wright; Elizabeth R Myers; Mathias P Bostrom
Journal:  J Orthop Res       Date:  2006-08       Impact factor: 3.494

7.  Side-to-side and within-side variability of 3D bone microarchitecture by conventional micro-computed tomography of paired iliac crest biopsies.

Authors:  C Chappard; A Marchadier; C L Benhamou
Journal:  Bone       Date:  2008-03-18       Impact factor: 4.398

8.  Ultrastructural properties in cortical bone vary greatly in two inbred strains of mice as assessed by synchrotron light based micro- and nano-CT.

Authors:  Philipp Schneider; Martin Stauber; Romain Voide; Marco Stampanoni; Leah Rae Donahue; Ralph Müller
Journal:  J Bone Miner Res       Date:  2007-10       Impact factor: 6.741

9.  Genetic variability in adult bone density among inbred strains of mice.

Authors:  W G Beamer; L R Donahue; C J Rosen; D J Baylink
Journal:  Bone       Date:  1996-05       Impact factor: 4.398

10.  Morphometric analysis of human bone biopsies: a quantitative structural comparison of histological sections and micro-computed tomography.

Authors:  R Müller; H Van Campenhout; B Van Damme; G Van Der Perre; J Dequeker; T Hildebrand; P Rüegsegger
Journal:  Bone       Date:  1998-07       Impact factor: 4.398

View more
  18 in total

1.  The effect of scan parameters on cone beam CT trabecular bone microstructural measurements of the human mandible.

Authors:  N Ibrahim; A Parsa; B Hassan; P van der Stelt; I H A Aartman; D Wismeijer
Journal:  Dentomaxillofac Radiol       Date:  2013-10-16       Impact factor: 2.419

2.  Integral-geometry characterization of photobiomodulation effects on retinal vessel morphology.

Authors:  Marconi Barbosa; Riccardo Natoli; Kriztina Valter; Jan Provis; Ted Maddess
Journal:  Biomed Opt Express       Date:  2014-06-18       Impact factor: 3.732

3.  A naturally occurring naringenin derivative exerts potent bone anabolic effects by mimicking oestrogen action on osteoblasts.

Authors:  Gaurav Swarnkar; Kunal Sharan; Jawed A Siddiqui; Jay Sharan Mishra; Kainat Khan; Mohd Parvez Khan; Varsha Gupta; Preeti Rawat; Rakesh Maurya; Anil K Dwivedi; Sabyasachi Sanyal; Naibedya Chattopadhyay
Journal:  Br J Pharmacol       Date:  2012-03       Impact factor: 8.739

Review 4.  A review of mouse critical size defect models in weight bearing bones.

Authors:  Jonathan S Harris; Thomas B Bemenderfer; Alexander R Wessel; Melissa A Kacena
Journal:  Bone       Date:  2013-02-14       Impact factor: 4.398

5.  3D image registration is critical to ensure accurate detection of longitudinal changes in trabecular bone density, microstructure, and stiffness measurements in rat tibiae by in vivo microcomputed tomography (μCT).

Authors:  Shenghui Lan; Shiming Luo; Beom Kang Huh; Abhishek Chandra; Allison R Altman; Ling Qin; X Sherry Liu
Journal:  Bone       Date:  2013-05-28       Impact factor: 4.398

6.  GRP78 plays an essential role in adipogenesis and postnatal growth in mice.

Authors:  Genyuan Zhu; Risheng Ye; Dae Young Jung; Ernesto Barron; Randall H Friedline; Vivian M Benoit; David R Hinton; Jason K Kim; Amy S Lee
Journal:  FASEB J       Date:  2012-11-24       Impact factor: 5.191

7.  Discovery of a tetrazolyl β-carboline with in vitro and in vivo osteoprotective activity under estrogen-deficient conditions.

Authors:  Anirudha Karvande; Shahnawaz Khan; Irfan Khan; Deepti Singh; Vikram Khedgikar; Priyanka Kushwaha; Naseer Ahmad; Priyanka Kothari; Anupam Dhasmana; Ruchir Kant; Ritu Trivedi; Prem M S Chauhan
Journal:  Medchemcomm       Date:  2018-06-12       Impact factor: 3.597

8.  Mineral and matrix changes in Brtl/+ teeth provide insights into mineralization mechanisms.

Authors:  Adele L Boskey; Kostas Verdelis; Lyudmila Spevak; Lyudmila Lukashova; Elia Beniash; Xu Yang; Wayne A Cabral; Joan C Marini
Journal:  Biomed Res Int       Date:  2013-05-29       Impact factor: 3.411

9.  Functionalized synchrotron in-line phase-contrast computed tomography: a novel approach for simultaneous quantification of structural alterations and localization of barium-labelled alveolar macrophages within mouse lung samples.

Authors:  Christian Dullin; Simeone dal Monego; Emanuel Larsson; Sara Mohammadi; Martin Krenkel; Chiara Garrovo; Stefania Biffi; Andrea Lorenzon; Andrea Markus; Joanna Napp; Tim Salditt; Agostino Accardo; Frauke Alves; Giuliana Tromba
Journal:  J Synchrotron Radiat       Date:  2015-01-01       Impact factor: 2.616

10.  Testosterone delivered with a scaffold is as effective as bone morphologic protein-2 in promoting the repair of critical-size segmental defect of femoral bone in mice.

Authors:  Bi-Hua Cheng; Tien-Min G Chu; Chawnshang Chang; Hong-Yo Kang; Ko-En Huang
Journal:  PLoS One       Date:  2013-08-05       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.