Literature DB >> 21620581

Cone-beam CT-based delineation of stereotactic lung targets: the influence of image modality and target size on interobserver variability.

Gabriela Altorjai1, Irina Fotina, Carola Lütgendorf-Caucig, Markus Stock, Richard Pötter, Dietmar Georg, Karin Dieckmann.   

Abstract

PURPOSE: It is generally agreed that the safe implementation of stereotactic body radiotherapy requires image guidance. The aim of this work was to assess interobserver variability in the delineation of lung lesions on cone-beam CT (CBCT) images compared with CT-based contouring for adaptive stereotactic body radiotherapy. The influence of target size was also evaluated. METHODS AND MATERIALS: Eight radiation oncologists delineated gross tumor volumes in 12 patient cases (non-small cell lung cancer I-II or solitary metastasis) on planning CTs and on CBCTs. Cases were divided into two groups with tumor diameters of less than (Group A) or more than 2 cm (Group B). Comparison of mean volumes delineated by all observers and range and coefficient of variation were reported for each case and image modality. Interobserver variability was assessed by means of standard error of measurement, conformity index (CI), and its generalized observer-independent approach. The variance between single observers on CT and CBCT images was measured via interobserver reliability coefficient.
RESULTS: Interobserver variability on CT images was 17% with 0.79 reliability, compared with 21% variability on CBCT and 0.76 reliability. On both image modalities, values of the intraobserver reliability coefficient (0.99 for CT and 0.97 for CBCT) indicated high reproducibility of results. In general, lower interobserver agreement was observed for small lesions (CI(genA) = 0.62 ± 0.06 vs. CI(genB) = 0.70 ± 0.03, p < 0.05). The analysis of single patient cases revealed that presence of spicules, diffuse infiltrations, proximity of the tumors to the vessels and thoracic wall, and respiration motion artifacts presented the main sources of the variability.
CONCLUSION: Interobserver variability for Stage I-II non-small cell lung cancer and lung metastasis was slightly higher on CBCT compared with CT. Absence of significant differences in interobserver variability suggests that CBCT imaging provides an effective tool for tumor localization, and image data could be also used for target volume delineation purposes.
Copyright © 2012 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2011        PMID: 21620581     DOI: 10.1016/j.ijrobp.2011.03.042

Source DB:  PubMed          Journal:  Int J Radiat Oncol Biol Phys        ISSN: 0360-3016            Impact factor:   7.038


  14 in total

1.  Critical discussion of evaluation parameters for inter-observer variability in target definition for radiation therapy.

Authors:  I Fotina; C Lütgendorf-Caucig; M Stock; R Pötter; D Georg
Journal:  Strahlenther Onkol       Date:  2012-01-27       Impact factor: 3.621

2.  An assessment of cone beam CT in the adaptive radiotherapy planning process for non-small-cell lung cancer patients.

Authors:  Aileen Duffton; Stephen Harrow; Carolynn Lamb; Mark McJury
Journal:  Br J Radiol       Date:  2016-04-07       Impact factor: 3.039

3.  Metal artifact correction for x-ray computed tomography using kV and selective MV imaging.

Authors:  Meng Wu; Andreas Keil; Dragos Constantin; Josh Star-Lack; Lei Zhu; Rebecca Fahrig
Journal:  Med Phys       Date:  2014-12       Impact factor: 4.071

4.  Cone-beam computed tomography in lung stereotactic ablative radiation therapy: predictive parameters of early response.

Authors:  Rosario Mazzola; Alba Fiorentino; Francesco Ricchetti; Niccolò Giaj Levra; Sergio Fersino; Gioacchino Di Paola; Antonio Lo Casto; Ruggero Ruggieri; Filippo Alongi
Journal:  Br J Radiol       Date:  2016-06-01       Impact factor: 3.039

5.  Quantitative cone-beam CT imaging in radiation therapy using planning CT as a prior: first patient studies.

Authors:  Tianye Niu; Ahmad Al-Basheer; Lei Zhu
Journal:  Med Phys       Date:  2012-04       Impact factor: 4.071

6.  Evaluation of 4-dimensional computed tomography to 4-dimensional cone-beam computed tomography deformable image registration for lung cancer adaptive radiation therapy.

Authors:  Salim Balik; Elisabeth Weiss; Nuzhat Jan; Nicholas Roman; William C Sleeman; Mirek Fatyga; Gary E Christensen; Cheng Zhang; Martin J Murphy; Jun Lu; Paul Keall; Jeffrey F Williamson; Geoffrey D Hugo
Journal:  Int J Radiat Oncol Biol Phys       Date:  2013-02-22       Impact factor: 7.038

7.  Interobserver size measurement variability in part-solid lung adenocarcinoma using pre-operative computed tomography.

Authors:  Kazutoshi Hamanaka; Hiroki Takayama; Tsutomu Koyama; Shunichiro Matsuoka; Tetsu Takeda; Hiroyuki Agatsuma; Kyoko Yamada; Akira Hyogotani; Satoshi Kawakami; Ken-Ichi Ito
Journal:  J Thorac Dis       Date:  2019-07       Impact factor: 2.895

8.  Comparison of internal target volumes defined on 3-dimensional, 4-dimensonal, and cone-beam CT images of non-small-cell lung cancer.

Authors:  Fengxiang Li; Jianbin Li; Zhifang Ma; Yingjie Zhang; Jun Xing; Huanpeng Qi; Dongping Shang
Journal:  Onco Targets Ther       Date:  2016-11-17       Impact factor: 4.147

9.  Distance deviation measure of contouring variability.

Authors:  Peter Rogelj; Robert Hudej; Primoz Petric
Journal:  Radiol Oncol       Date:  2013-02-01       Impact factor: 2.991

10.  Uncertainties in target volume delineation in radiotherapy - are they relevant and what can we do about them?

Authors:  Barbara Segedin; Primoz Petric
Journal:  Radiol Oncol       Date:  2016-05-09       Impact factor: 2.991

View more