Literature DB >> 21614749

Significant differentiation of focal breast lesions: raw data-based calculation of strain ratio.

T Fischer1, U Peisker, S Fiedor, T Slowinski, P Wedemeyer, F Diekmann, M Grigoryev, A Thomas.   

Abstract

PURPOSE: We compared elastography, B-mode ultrasound and mammography to determine whether raw data calculation of strain ratios (SRs) can further improve the differentiation of focal breast lesions.
MATERIALS AND METHODS: 201 women with histologically proven focal breast lesions (85 benign, 116 malignant) were included at two German breast centers. Patients underwent a standardized ultrasound procedure using high-end ultrasound system with a 9-MHz broadband linear transducer. Two experienced readers analyzed the B-mode scans and mammograms using the BI-RADS criteria, while elastograms were analyzed using the Tsukuba score. SRs were calculated from a tumor-adjusted ROI and a comparable ROI placed in the lateral fatty tissue. The sensitivity, specificity, and cutoff values were calculated for SRs (ROC analysis).
RESULTS: The median age was 53 years. The sensitivity and specificity were 85 %/ 60 % for B-mode scanning, 85 %/ 68 % for elastography, 78 %/ 62 % for mammography, and 95 %/ 74 % for SRs. An SR cutoff value of 2.27 (AUC 0.907) allowed significant differentiation (p < 0.001) between malignant and benign lesions. The quantitative SR calculation was superior to subjective interpretation of B-mode scans and sonoelastograms with a positive predictive value of 83 % versus 78 % and 74 %, and equal to mammograms.
CONCLUSION: Strain ratio calculation contributes to the standardization of sonoelastography with high sensitivity and allows significant differentiation between benign and malignant breast lesions with a higher specificity compared to B-mode, subjective evaluation of elastography and mammography. © Georg Thieme Verlag KG Stuttgart · New York.

Entities:  

Mesh:

Year:  2011        PMID: 21614749     DOI: 10.1055/s-0031-1273222

Source DB:  PubMed          Journal:  Ultraschall Med        ISSN: 0172-4614            Impact factor:   6.548


  26 in total

1.  Combination of two-dimensional shear wave elastography with ultrasound breast imaging reporting and data system in the diagnosis of breast lesions: a new method to increase the diagnostic performance.

Authors:  Dan-Dan Li; Hui-Xiong Xu; Le-Hang Guo; Xiao-Wan Bo; Xiao-Long Li; Rong Wu; Jun-Mei Xu; Yi-Feng Zhang; Kun Zhang
Journal:  Eur Radiol       Date:  2015-12-29       Impact factor: 5.315

2.  Can strain elastography combined with ultrasound breast imaging reporting and data system be a more effective method in the differentiation of benign and malignant breast lesions?

Authors:  Serdar Arslan; Nihal Uslu; Funda Ulu Ozturk; Eda Yilmaz Akcay; Tugan Tezcaner; Ahmet Muhtesem Agildere
Journal:  J Med Ultrason (2001)       Date:  2017-02-02       Impact factor: 1.314

3.  Auto strain ratio system for the quality control of breast strain elastography.

Authors:  Kazutaka Nakashima; Akiko Mizutou; Sayaka Sakurai
Journal:  J Med Ultrason (2001)       Date:  2017-09-27       Impact factor: 1.314

4.  [Elastography as an additional tool in breast sonography. Technical principles and clinical applications].

Authors:  D Rjosk-Dendorfer; A Reichelt; D-A Clevert
Journal:  Radiologe       Date:  2014-03       Impact factor: 0.635

5.  Sonoelastographic strain ratio: how does the position of reference fat influence it?

Authors:  Na Young Jung; Chang Suk Park; Sung Hun Kim; Hyun Seouk Jung; Kijun Kim; Jung Whee Lee; Yu Ri Shin; Se-Jeong Oh
Journal:  Jpn J Radiol       Date:  2016-04-08       Impact factor: 2.374

Review 6.  Grey-scale sonography and sonoelastography for diagnosing carpal tunnel syndrome.

Authors:  Hideaki Miyamoto; Yutaka Morizaki; Takahiro Kashiyama; Sakae Tanaka
Journal:  World J Radiol       Date:  2016-03-28

7.  Strain sonoelastography of inflammatory myopathies: comparison with clinical examination, magnetic resonance imaging and pathologic findings.

Authors:  Yoonah Song; Seunghun Lee; Dae Hyun Yoo; Ki-Seok Jang; Jiyoon Bae
Journal:  Br J Radiol       Date:  2016-07-12       Impact factor: 3.039

Review 8.  JSUM ultrasound elastography practice guidelines: breast.

Authors:  Kazutaka Nakashima; Tsuyoshi Shiina; Masaru Sakurai; Katsutoshi Enokido; Tokiko Endo; Hiroko Tsunoda; Etsuo Takada; Takeshi Umemoto; Ei Ueno
Journal:  J Med Ultrason (2001)       Date:  2013-07-31       Impact factor: 1.314

9.  Evaluation of the diagnostic efficacy of strain elastography in infertile population with normal and abnormal semen parameters.

Authors:  Faruk Küçükdurmaz; Mehmet Akif Sarıca; Özcan Emre; Murat Baykara; Betül Kızıldağ; Sefa Resim
Journal:  Turk J Urol       Date:  2017-07-31

10.  Modeling Uncertainty of Strain Ratio Measurements in Ultrasound Breast Strain Elastography: A Factorial Experiment.

Authors:  David Rosen; Jingfeng Jiang
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2019-09-23       Impact factor: 2.725

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.