Literature DB >> 19619697

Correlation of impedance cardiography with invasive hemodynamic measurements in patients with advanced heart failure: the BioImpedance CardioGraphy (BIG) substudy of the Evaluation Study of Congestive Heart Failure and Pulmonary Artery Catheterization Effectiveness (ESCAPE) Trial.

Sandeep A Kamath1, Mark H Drazner, Gudaye Tasissa, Joseph G Rogers, Lynne Warner Stevenson, Clyde W Yancy.   

Abstract

BACKGROUND: Impedance cardiography (ICG) is a noninvasive modality that uses changes in impedance across the thorax to assess hemodynamic parameters, including cardiac output (CO). The utility of ICG in patients hospitalized with heart failure is uncertain.
METHODS: The BioImpedance CardioGraphy in Advanced Heart Failure study was a prospective substudy of the Evaluation Study of Congestive Heart Failure and Pulmonary Artery Catheterization Effectiveness. A total of 170 subjects underwent blinded ICG measurements using BioZ (CardioDynamics, San Diego, CA); of these, 82 underwent right heart catheterization. We compared ICG with invasively measured hemodynamics by simple correlation and compared overall ICG hemodynamic profiles ("wet" [thoracic fluid content > or =47/kOhm in men and > or =37/kOhm in women] and "cold" [cardiac index < or =2.2 L min(-1)m(-2)) versus those determined by invasive measurements (wet [pulmonary capillary wedge pressure > or =22 mm Hg] and cold [cardiac index < or =2.2 L min(-1)m(-2)). We also determined whether ICG measurements were associated with subsequent death or hospitalization within 6 months.
RESULTS: There was modest correlation between ICG and invasively measured CO (r = 0.4 to 0.6 on serial measurement). Thoracic fluid content measured by ICG was not a reliable measure of pulmonary capillary wedge pressure. There was poor agreement between ICG and invasively measured hemodynamic profiles (kappa < or =0.1). No ICG variable alone or in combination was associated with outcome.
CONCLUSIONS: In hospitalized patients with advanced heart failure, ICG provides some information about CO but not left-sided filling pressures. Impedance cardiography did not have prognostic utility in this patient population.

Entities:  

Mesh:

Year:  2009        PMID: 19619697      PMCID: PMC2720805          DOI: 10.1016/j.ahj.2009.06.002

Source DB:  PubMed          Journal:  Am Heart J        ISSN: 0002-8703            Impact factor:   4.749


  14 in total

1.  Relationship between right and left-sided filling pressures in 1000 patients with advanced heart failure.

Authors:  M H Drazner; M A Hamilton; G Fonarow; J Creaser; C Flavell; L W Stevenson
Journal:  J Heart Lung Transplant       Date:  1999-11       Impact factor: 10.247

2.  Comparison of impedance cardiography with invasive hemodynamic measurements in patients with heart failure secondary to ischemic or nonischemic cardiomyopathy.

Authors:  Mark H Drazner; Brenda Thompson; Paul B Rosenberg; Patricia A Kaiser; James D Boehrer; Brian J Baldwin; Daniel L Dries; Clyde W Yancy
Journal:  Am J Cardiol       Date:  2002-04-15       Impact factor: 2.778

Review 3.  Noninvasive assessment of hemodynamics: an emphasis on bioimpedance cardiography.

Authors:  P Rosenberg; C W Yancy
Journal:  Curr Opin Cardiol       Date:  2000-05       Impact factor: 2.161

4.  Evaluation Study of Congestive Heart Failure and Pulmonary Artery Catheterization Effectiveness (ESCAPE): design and rationale.

Authors:  M R Shah; C M O'Connor; G Sopko; V Hasselblad; R M Califf; L W Stevenson
Journal:  Am Heart J       Date:  2001-04       Impact factor: 4.749

5.  Equivalence of the bioimpedance and thermodilution methods in measuring cardiac output in hospitalized patients with advanced, decompensated chronic heart failure.

Authors:  Nancy M Albert; Melanie D Hail; Jianbo Li; James B Young
Journal:  Am J Crit Care       Date:  2004-11       Impact factor: 2.228

6.  Value of clinician assessment of hemodynamics in advanced heart failure: the ESCAPE trial.

Authors:  Mark H Drazner; Anne S Hellkamp; Carl V Leier; Monica R Shah; Leslie W Miller; Stuart D Russell; James B Young; Robert M Califf; Anju Nohria
Journal:  Circ Heart Fail       Date:  2008-09       Impact factor: 8.790

7.  Evaluation study of congestive heart failure and pulmonary artery catheterization effectiveness: the ESCAPE trial.

Authors:  Cynthia Binanay; Robert M Califf; Vic Hasselblad; Christopher M O'Connor; Monica R Shah; George Sopko; Lynne W Stevenson; Gary S Francis; Carl V Leier; Leslie W Miller
Journal:  JAMA       Date:  2005-10-05       Impact factor: 56.272

8.  Equivalence of bioimpedance and thermodilution in measuring cardiac index after cardiac surgery.

Authors:  W Scott Sageman; Robert H Riffenburgh; Bruce D Spiess
Journal:  J Cardiothorac Vasc Anesth       Date:  2002-02       Impact factor: 2.628

9.  Evaluation of impedance cardiography as an alternative to pulmonary artery catheterization in critically ill patients.

Authors:  Marc A Silver; Pamela Cianci; Sharon Brennan; Helen Longeran-Thomas; Faheem Ahmad
Journal:  Congest Heart Fail       Date:  2004 Mar-Apr

10.  Impedance cardiography: the next vital sign technology?

Authors:  Joseph M Van De Water; Timothy W Miller; Robert L Vogel; Bruce E Mount; Martin L Dalton
Journal:  Chest       Date:  2003-06       Impact factor: 9.410

View more
  12 in total

1.  Evaluation of heart function with impedance cardiography in acute myocardial infarction patients.

Authors:  Shun-Juan Chen; Zhu Gong; Qiang-Lin Duan
Journal:  Int J Clin Exp Med       Date:  2014-03-15

2.  Value of impedance cardiography in patients studied for pulmonary hypertension.

Authors:  Adriano R Tonelli; Hassan Alnuaimat; Ning Li; Robin Carrie; Kamal K Mubarak
Journal:  Lung       Date:  2011-05-24       Impact factor: 2.584

Review 3.  Wearable technology for cardiology: An update and framework for the future.

Authors:  Joshua M Pevnick; Kade Birkeland; Raymond Zimmer; Yaron Elad; Ilan Kedan
Journal:  Trends Cardiovasc Med       Date:  2017-08-09       Impact factor: 6.677

4.  Measurement of cardiac output in children by bioreactance.

Authors:  Yolanda Ballestero; Jesús López-Herce; Javier Urbano; Maria José Solana; Marta Botrán; Jose M Bellón; Angel Carrillo
Journal:  Pediatr Cardiol       Date:  2011-02-13       Impact factor: 1.655

5.  Effects of supervised exercise and dietary nitrate in older adults with controlled hypertension and/or heart failure with preserved ejection fraction.

Authors:  Hossam A Shaltout; Joel Eggebeen; Anthony P Marsh; Peter H Brubaker; Paul J Laurienti; Jonathan H Burdette; Swati Basu; Ashley Morgan; Patricia C Dos Santos; James L Norris; Timothy M Morgan; Gary D Miller; W Jack Rejeski; Amret T Hawfield; Debra I Diz; J Thomas Becton; Daniel B Kim-Shapiro; Dalane W Kitzman
Journal:  Nitric Oxide       Date:  2017-05-23       Impact factor: 4.427

6.  Detection of Low Cardiac Index using a Polyvinylidene Fluoride-Based Wearable Ring and Convolutional Neural Networks.

Authors:  Sardar Ansari; Jessica R Golbus; Mohamad H Tiba; Brendan McCracken; Lu Wang; Keith D Aaronson; Kevin R Ward; Kayvan Najarian; Kenn R Oldham
Journal:  IEEE Sens J       Date:  2020-11-03       Impact factor: 4.325

Review 7.  Wearables in Cardiovascular Disease.

Authors:  Sanchit Kumar; Angela M Victoria-Castro; Hannah Melchinger; Kyle D O'Connor; Mitchell Psotka; Nihar R Desai; Tariq Ahmad; F Perry Wilson
Journal:  J Cardiovasc Transl Res       Date:  2022-09-09       Impact factor: 3.216

8.  Derivation of baseline lung impedance in chronic heart failure patients: use for monitoring pulmonary congestion and predicting admissions for decompensation.

Authors:  Michael Shochat; Avraham Shotan; David S Blondheim; Mark Kazatsker; Iris Dahan; Aya Asif; Ilia Shochat; Aaron Frimerman; Yoseph Rozenman; Simcha R Meisel
Journal:  J Clin Monit Comput       Date:  2014-09-06       Impact factor: 2.502

9.  Validation of stroke volume and cardiac output by electrical interrogation of the brachial artery in normals: assessment of strengths, limitations, and sources of error.

Authors:  Donald P Bernstein; Isaac C Henry; Harry J Lemmens; Janell L Chaltas; Anthony N DeMaria; James B Moon; Andrew M Kahn
Journal:  J Clin Monit Comput       Date:  2015-02-15       Impact factor: 2.502

10.  Applicability of Impedance Cardiography During Heart Failure Flare-Ups.

Authors:  Saulius Sadauskas; Albinas Naudžiūnas; Alvydas Unikauskas; Edita Mašanauskienė; Giedrė Bakšytė; Andrius Macas
Journal:  Med Sci Monit       Date:  2016-10-09
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.