Impedance cardiography: A valuable method of evaluating haemodynamic parameters.

Tomasz Sodolski, Andrzej Kutarski.   

Abstract

This year marks 40 years since the technique was designed of measuring and monitoring the basic haemodynamic parameters in humans by means of impedance cardiography (ICG), also known as "impedance plethysmography of the chest", "electrical bioimpedance of the chest" or "reocardiography". The method makes it possible to denote stroke volume and cardiac output. It also enables the factors to be assessed that influence the following: preload (measurement of thoracic fluid content), afterload (measurement of systemic vascular resistance), the systemic vascular resistance index, contractibility (measurement of the acceleration index), the velocity index, the pre-ejection period, left ventricular ejection time, systolic time ratio and heart rate. Advances in hardware and software, including digital signal tooling and new algorithms, have certainly improved the quality of the results obtained. The accuracy and repeatability of the results have been confirmed in comparative studies with results obtained through invasive methods and echocardiography. Not only are haemodynamic changes monitored by means of ICG in intensive care units, in operating theatres and at haemodialysis stations, but repeated measurements also provide haemodynamic information during the treatment of patients with hypertension and heart failure and pregnant women with cardiological problems and gestosis. A single ICG investigation makes a great contribution to the basic information available about the circulatory system, which is helpful in the initial evaluation of patients in a severe general condition (for example in the admission room), and also makes it possible to make a swift diagnosis of the cause of complaints such as dyspnoea and hypotonia. A particular application of ICG is the assessment of haemodynamic parameters during the programming of atrioventricular and CRT pacemakers. Besides these uses, ICG is a valuable investigative tool. It is defect-free and does not have pulmonary artery pressure monitoring limitations. Moreover, it is not as time-consuming as echocardiography and the examination can be performed by trained technicians or nurses. (Cardiol J 2007; 14: 115-126).

Entities:  

Year:  2007        PMID: 18651447

Source DB:  PubMed          Journal:  Cardiol J        ISSN: 1898-018X            Impact factor:   2.737


  15 in total

1.  Value of impedance cardiography during 6-minute walk test in pulmonary hypertension.

Authors:  Adriano R Tonelli; Laith Alkukhun; Vineesha Arelli; José Ramos; Jennie Newman; Kevin McCarthy; Bohdan Pichurko; Omar A Minai; Raed A Dweik
Journal:  Clin Transl Sci       Date:  2013-09-06       Impact factor: 4.689

2.  Value of impedance cardiography in patients studied for pulmonary hypertension.

Authors:  Adriano R Tonelli; Hassan Alnuaimat; Ning Li; Robin Carrie; Kamal K Mubarak
Journal:  Lung       Date:  2011-05-24       Impact factor: 2.584

3.  Effects of supervised exercise and dietary nitrate in older adults with controlled hypertension and/or heart failure with preserved ejection fraction.

Authors:  Hossam A Shaltout; Joel Eggebeen; Anthony P Marsh; Peter H Brubaker; Paul J Laurienti; Jonathan H Burdette; Swati Basu; Ashley Morgan; Patricia C Dos Santos; James L Norris; Timothy M Morgan; Gary D Miller; W Jack Rejeski; Amret T Hawfield; Debra I Diz; J Thomas Becton; Daniel B Kim-Shapiro; Dalane W Kitzman
Journal:  Nitric Oxide       Date:  2017-05-23       Impact factor: 4.427

4.  Moldable and Transferrable Conductive Nanocomposites for Epidermal Electronics.

Authors:  Myeong Namkoong; Heng Guo; Md Saifur Rahman; Daniel Wang; Cassandra Jane Pfeil; Sophia Hager; Limei Tian
Journal:  Npj Flex Electron       Date:  2022-06-07

5.  Influence of atrioventricular optimization on hemodynamic parameters and quality of life in patients with dual chamber pacemaker with ventricular lead in right ventricular outflow tract.

Authors:  Artur Klimczak; Adam S Budzikowski; Marcin Rosiak; Marzenna Zielińska; Bożena Urbanek; Karol Bartczak; Michał Chudzik; Jerzy K Wranicz
Journal:  Ann Noninvasive Electrocardiol       Date:  2014-03-06       Impact factor: 1.468

6.  The maternal venous system: the ugly duckling of obstetrics.

Authors:  K Tomsin
Journal:  Facts Views Vis Obgyn       Date:  2013

7.  Effect of passive leg raising on systemic hemodynamics of pregnant women: a dynamic assessment of maternal cardiovascular function at 22-24 weeks of gestation.

Authors:  Åse Vårtun; Kari Flo; Ganesh Acharya
Journal:  PLoS One       Date:  2014-04-14       Impact factor: 3.240

8.  Correlation between impedance cardiography and 6 min walk distance in atrial fibrillation patients.

Authors:  Ling Ding; Xiao-Qing Quan; Shu Zhang; Lei Ruan; Le Zhang; Kai Zheng; Wei-Wei Yu; Xiao-Fen Wu; Tao Mi; Cun-Tai Zhang; Hong-Lian Zhou
Journal:  BMC Cardiovasc Disord       Date:  2016-06-10       Impact factor: 2.298

9.  A hybrid approach for quantifying aortic valve stenosis using impedance cardiography and echocardiography.

Authors:  Yunis Daralammouri; Khubaib Ayoub; Najwan Badrieh; Bernward Lauer
Journal:  BMC Cardiovasc Disord       Date:  2016-01-22       Impact factor: 2.298

10.  Visual Impairment does not Limit Training Effects in Development of Aerobic and Anaerobic Capacity in Tandem Cyclists.

Authors:  Kamelska Anna Malwina; Mazurek Krzysztof; Zmijewski Piotr
Journal:  J Hum Kinet       Date:  2015-01-12       Impact factor: 2.193

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.