BACKGROUND: Current etiologic theories concerning healing rates in rotator cuff repair have focused on the blood supply in the tendinous portion of the cuff. We currently have little information regarding the effect of our repair techniques on this critical variable. We hypothesize that intratendinous blood flow is changed during transosseus equivalent tendon fixation. METHODS: Eighteen consecutive patients with rotator cuff tears amenable to double row fixation were included in the study. Each patient underwent a standard arthroscopic transosseous equivalent double row fixation procedure using the Arthrex SutureBridge technique (Arthrex, Naples, FL, USA). After tying down of the medial row, a first set of recordings was taken using a custom laser doppler flowmetry probe (Perimed, Inc., Ohio, USA). A second recording was made following securing of the lateral PushLock anchors. The data were compared to determine the overall effect on blood flow associated with this technique. RESULTS: Summated averages for the 2 groups show a significant (44.67%) decline in the blood flow present after the second row of implants are placed (P < .01). Individual calculations for regions of the cuff tear indicate significant differences in anterior third (P = .01), middle third (P < .01), and posterior third (P = .02) of the tear after transosseous equivalent fixation. CONCLUSION: Completion of the construct with lateral anchors in the transosseous equivalent technique results in reduced but preserved blood flow in the tendon repair site. Further study is required to determine the implications for tendon healing. CLINICAL RELEVANCE: Intratendinous blood flow is a variable that should be considered when evaluating repair methods in rotator cuff surgery. Copyright Â
BACKGROUND: Current etiologic theories concerning healing rates in rotator cuff repair have focused on the blood supply in the tendinous portion of the cuff. We currently have little information regarding the effect of our repair techniques on this critical variable. We hypothesize that intratendinous blood flow is changed during transosseus equivalent tendon fixation. METHODS: Eighteen consecutive patients with rotator cuff tears amenable to double row fixation were included in the study. Each patient underwent a standard arthroscopic transosseous equivalent double row fixation procedure using the Arthrex SutureBridge technique (Arthrex, Naples, FL, USA). After tying down of the medial row, a first set of recordings was taken using a custom laser doppler flowmetry probe (Perimed, Inc., Ohio, USA). A second recording was made following securing of the lateral PushLock anchors. The data were compared to determine the overall effect on blood flow associated with this technique. RESULTS: Summated averages for the 2 groups show a significant (44.67%) decline in the blood flow present after the second row of implants are placed (P < .01). Individual calculations for regions of the cuff tear indicate significant differences in anterior third (P = .01), middle third (P < .01), and posterior third (P = .02) of the tear after transosseous equivalent fixation. CONCLUSION: Completion of the construct with lateral anchors in the transosseous equivalent technique results in reduced but preserved blood flow in the tendon repair site. Further study is required to determine the implications for tendon healing. CLINICAL RELEVANCE: Intratendinous blood flow is a variable that should be considered when evaluating repair methods in rotator cuff surgery. Copyright Â
Authors: Olaf Lorbach; Mike H Baums; Tanja Kostuj; Stephan Pauly; Markus Scheibel; Andrew Carr; Nasim Zargar; Maristella F Saccomanno; Giuseppe Milano Journal: Knee Surg Sports Traumatol Arthrosc Date: 2015-01-09 Impact factor: 4.342
Authors: Werner Anderl; Philipp R Heuberer; Brenda Laky; Bernhard Kriegleder; Roland Reihsner; Josef Eberhardsteiner Journal: Knee Surg Sports Traumatol Arthrosc Date: 2012-02-26 Impact factor: 4.342
Authors: P Boyer; C Bouthors; T Delcourt; O Stewart; F Hamida; G Mylle; P Massin Journal: Knee Surg Sports Traumatol Arthrosc Date: 2013-02-13 Impact factor: 4.342
Authors: Stephan Frosch; Gottfried Buchhorn; Anja Hoffmann; Peter Balcarek; Jan Philipp Schüttrumpf; Florian August; Klaus Michael Stürmer; Hans Joachim Walde; Tim Alexander Walde Journal: Knee Surg Sports Traumatol Arthrosc Date: 2014-04-23 Impact factor: 4.342
Authors: Philipp R Heuberer; Leo Pauzenberger; Michael S Gruber; Bernhard Kriegleder; Roman C Ostermann; Brenda Laky; Werner Anderl Journal: Knee Surg Sports Traumatol Arthrosc Date: 2019-05-06 Impact factor: 4.342