A comparison of the i-gel and classic LMA insertion in manikins by experienced and novice physicians.

Konstantinos Stroumpoulis1, Christina Isaia, Eleni Bassiakou, Ioannis Pantazopoulos, Georgios Troupis, Antonios Mazarakis, Theano Demestiha, Theodoros Xanthos.   

Abstract

OBJECTIVE: Airway management is of utmost importance in critical patients, for whom endotracheal intubation remains the gold standard. However, it is a difficult skill to acquire and success rates in novices are unacceptably low. Supraglottic devices constitute promising alternatives. The aim of this study was to assess the use of laryngeal mask airway (LMA) classic LMA (cLMA) and a relatively new supraglottic device, the i-gel, in experienced and novice doctors in a manikin setting.
METHODS: The study population comprised 116 doctors. After a brief educational session and presentation of cLMA and i-gel, participants were randomly allocated to insert both devices in an adult manikin. Insertions were performed using a size-4 cLMA and a size-4 i-gel. The primary endpoints were the success rate for each device and the duration of the insertion attempt. Secondary endpoint was the perception of ease of use with each device.
RESULTS: First attempt success rate was 90.5% for i-gel and 63.8% for cLMA (P<0.001). I-gel use reduced insertion times (13.32±4.99 s vs. 17.99±6.87 s, P<0.001) and was related with significantly higher first attempt success rates than cLMA in novices (90 vs. 48.3%, P<0.001). In addition, i-gel use provided almost equal success rates for experienced and novice doctors (91 vs. 90%, P=not significant), whereas cLMA use resulted in significantly lower success rates for novices (48.3 vs. 80.4%, P<0.001).
CONCLUSION: In this manikin setting i-gel significantly improved success rates and insertion time compared with cLMA. Most importantly, i-gel use resulted in high first pass success rates for novice doctors, equal to those achieved by experienced doctors.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 21593672     DOI: 10.1097/MEJ.0b013e3283474ab3

Source DB:  PubMed          Journal:  Eur J Emerg Med        ISSN: 0969-9546            Impact factor:   2.799


  11 in total

1.  Comparison of insertion of the modified i-gel airway for oral surgery with the LMA Flexible: a manikin study.

Authors:  Takuro Sanuki; Shingo Sugioka; Nobuyasu Komasawa; Ryusuke Ueki; Yoshiroh Kaminoh; Junichiro Kotani
Journal:  Anesth Prog       Date:  2014

2.  Comparison of the Success Rate of Laryngeal Mask Air Way Insertion in Classic & Rotatory Methods in Pediatric Patients Undergoing General Anesthesia.

Authors:  Mir Mousa Aghdashi; Mohammad Amin Valizade Hasanloei; Rahman Abbasivash; Shahram Shokouhi; Shahram Salehi Gharehvaran
Journal:  Anesth Pain Med       Date:  2017-01-24

3.  Comparison of learning performance of 2 intubating laryngeal mask airways in novice: A randomized crossover manikin study.

Authors:  Zi-Jia Liu; Jie Yi; Wei-Yun Chen; Xiu-Hua Zhang; Yu-Guang Huang
Journal:  Medicine (Baltimore)       Date:  2017-05       Impact factor: 1.889

4.  Comparison of the i-gel and other supraglottic airways in adult manikin studies: Systematic review and meta-analysis.

Authors:  Jiwon An; Sang Beom Nam; Jong Seok Lee; Jinae Lee; Hanna Yoo; Hye Mi Lee; Min-Soo Kim
Journal:  Medicine (Baltimore)       Date:  2017-01       Impact factor: 1.889

5.  ETView VivaSight single lumen vs. conventional intubation in simulated studies: a systematic review and meta-analysis.

Authors:  Seok Kyeong Oh; Byung Gun Lim; Young Sung Kim; Jae Hak Lee; Young Ju Won
Journal:  J Int Med Res       Date:  2020-06       Impact factor: 1.671

6.  Comparing Surf Lifeguards and Nurse Anesthetists' Use of the i-gel Supraglottic Airway Device - An Observational Simulation Study.

Authors:  Louise Nørkjær; Mathilde Stærk; Kasper G Lauridsen; Tabita K Gallacher; Jakob B Løyche; Kristian Krogh; Bo Løfgren
Journal:  Open Access Emerg Med       Date:  2020-04-02

7.  Assessment of Success and Ease of Insertion of ProSeal™ Laryngeal Mask Airway versus I-gel™ Insertion by Paramedics in Simulated Difficult Airway Using Cervical Collar in Different Positions in Manikins.

Authors:  Arushi Gupta; Ankita Kabi; Divya Gaur
Journal:  Anesth Essays Res       Date:  2021-05-06

8.  Reverse technique for I-gel supraglottic airway insertion.

Authors:  Indu Sen; Neerja Bhardwaj; Ys Latha
Journal:  J Anaesthesiol Clin Pharmacol       Date:  2013-01

9.  Utility of the Aintree Intubation Catheter in fiberoptic tracheal intubation through the three types of intubating supraglottic airways: a manikin simulation study.

Authors:  Ryusuke Ueki; Nobuyasu Komasawa; Kenta Nishimoto; Takashi Sugi; Munetaka Hirose; Yoshiroh Kaminoh
Journal:  J Anesth       Date:  2013-10-17       Impact factor: 2.078

10.  Endotracheal intubation using i-gel® and lightwand in a patient with difficult airway: a case report.

Authors:  Chun Gil Choi; Ki-Hwan Yang; Jong-Kwon Jung; Jeong Uk Han; Choon Soo Lee; Young-Deog Cha; Jang-Ho Song
Journal:  Korean J Anesthesiol       Date:  2015-09-30
View more