Literature DB >> 21590802

Optimization of spiral-based pulse sequences for first-pass myocardial perfusion imaging.

Michael Salerno1, Christopher T Sica, Christopher M Kramer, Craig H Meyer.   

Abstract

Although spiral trajectories have multiple attractive features such as their isotropic resolution, acquisition efficiency, and robustness to motion, there has been limited application of these techniques to first-pass perfusion imaging because of potential off-resonance and inconsistent data artifacts. Spiral trajectories may also be less sensitive to dark-rim artifacts that are caused, at least in part, by cardiac motion. By careful consideration of the spiral trajectory readout duration, flip angle strategy, and image reconstruction strategy, spiral artifacts can be abated to create high-quality first-pass myocardial perfusion images with high signal-to-noise ratio. The goal of this article was to design interleaved spiral pulse sequences for first-pass myocardial perfusion imaging and to evaluate them clinically for image quality and the presence of dark-rim, blurring, and dropout artifacts.
Copyright © 2011 Wiley-Liss, Inc.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21590802      PMCID: PMC3134590          DOI: 10.1002/mrm.22746

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  25 in total

1.  Multislice first-pass cardiac perfusion MRI: validation in a model of myocardial infarction.

Authors:  Frederick H Epstein; James F London; Dana C Peters; Lino M Goncalves; Kwabena Agyeman; Joni Taylor; Robert S Balaban; Andrew E Arai
Journal:  Magn Reson Med       Date:  2002-03       Impact factor: 4.668

2.  Comparison of fat suppression strategies in 3D spiral coronary magnetic resonance angiography.

Authors:  Peter Börnert; Matthias Stuber; René M Botnar; Kraig V Kissinger; Warren J Manning
Journal:  J Magn Reson Imaging       Date:  2002-04       Impact factor: 4.813

3.  Spiral magnetic resonance coronary angiography with rapid real-time localization.

Authors:  Phillip C Yang; Craig H Meyer; Masahiro Terashima; Shuichiro Kaji; Michael V McConnell; A l Macovski; John M Pauly; Dwight G Nishimura; Bob S Hu
Journal:  J Am Coll Cardiol       Date:  2003-04-02       Impact factor: 24.094

4.  Band artifacts due to bulk motion.

Authors:  Pippa Storey; Qun Chen; Wei Li; Robert R Edelman; Pottumarthi V Prasad
Journal:  Magn Reson Med       Date:  2002-12       Impact factor: 4.668

5.  Effects of missing dynamic images on myocardial perfusion reserve index calculation: comparison between an every heartbeat and an alternate heartbeat acquisition.

Authors:  Holger Thiele; Sven Plein; John P Ridgway; Marcel Breeuwer; David Higgins; Gerhard Schuler; Mohan Sivananthan
Journal:  J Cardiovasc Magn Reson       Date:  2003       Impact factor: 5.364

6.  Extended coverage first-pass perfusion imaging using slice-interleaved TSENSE.

Authors:  P Kellman; J A Derbyshire; K O Agyeman; E R McVeigh; A E Arai
Journal:  Magn Reson Med       Date:  2004-01       Impact factor: 4.668

7.  Fast spiral coronary artery imaging.

Authors:  C H Meyer; B S Hu; D G Nishimura; A Macovski
Journal:  Magn Reson Med       Date:  1992-12       Impact factor: 4.668

8.  Spiral magnetic resonance coronary angiography--direct comparison of 1.5 Tesla vs. 3 Tesla.

Authors:  Phillip C Yang; Patricia Nguyen; Ann Shimakawa; Jean Brittain; John Pauly; Dwight Nishimura; Bob Hu; Michael McConnell
Journal:  J Cardiovasc Magn Reson       Date:  2004       Impact factor: 5.364

9.  A velocity k-space analysis of flow effects in echo-planar and spiral imaging.

Authors:  D G Nishimura; P Irarrazabal; C H Meyer
Journal:  Magn Reson Med       Date:  1995-04       Impact factor: 4.668

10.  Multislice first-pass myocardial perfusion imaging: Comparison of saturation recovery (SR)-TrueFISP-two-dimensional (2D) and SR-TurboFLASH-2D pulse sequences.

Authors:  Michael Fenchel; Uwe Helber; Orlando P Simonetti; Norbert I Stauder; Ulrich Kramer; Co-Nghi Nguyen; J Paul Finn; Claus D Claussen; Stephan Miller
Journal:  J Magn Reson Imaging       Date:  2004-05       Impact factor: 4.813

View more
  20 in total

Review 1.  Recent Advances in Cardiovascular Magnetic Resonance: Techniques and Applications.

Authors:  Michael Salerno; Behzad Sharif; Håkan Arheden; Andreas Kumar; Leon Axel; Debiao Li; Stefan Neubauer
Journal:  Circ Cardiovasc Imaging       Date:  2017-06       Impact factor: 7.792

2.  Free-breathing cardiac MR stress perfusion with real-time slice tracking.

Authors:  Tamer A Basha; Sébastien Roujol; Kraig V Kissinger; Beth Goddu; Sophie Berg; Warren J Manning; Reza Nezafat
Journal:  Magn Reson Med       Date:  2013-10-07       Impact factor: 4.668

3.  Non-Cartesian slice-GRAPPA and slice-SPIRiT reconstruction methods for multiband spiral cardiac MRI.

Authors:  Changyu Sun; Yang Yang; Xiaoying Cai; Michael Salerno; Craig H Meyer; Daniel Weller; Frederick H Epstein
Journal:  Magn Reson Med       Date:  2019-09-30       Impact factor: 4.668

4.  Whole-heart spiral simultaneous multi-slice first-pass myocardial perfusion imaging.

Authors:  Yang Yang; Craig H Meyer; Frederick H Epstein; Christopher M Kramer; Michael Salerno
Journal:  Magn Reson Med       Date:  2018-10-12       Impact factor: 4.668

5.  Myocardial perfusion MRI with an undersampled 3D stack-of-stars sequence.

Authors:  Liyong Chen; Ganesh Adluru; Matthias C Schabel; Chris J McGann; Edward V R Dibella
Journal:  Med Phys       Date:  2012-08       Impact factor: 4.071

6.  Combined outer volume suppression and T2 preparation sequence for coronary angiography.

Authors:  Jieying Luo; Nii Okai Addy; R Reeve Ingle; Brian A Hargreaves; Bob S Hu; Dwight G Nishimura; Taehoon Shin
Journal:  Magn Reson Med       Date:  2014-12-17       Impact factor: 4.668

7.  Three-dimensional first-pass myocardial perfusion MRI using a stack-of-spirals acquisition.

Authors:  Taehoon Shin; Krishna S Nayak; Juan M Santos; Dwight G Nishimura; Bob S Hu; Michael V McConnell
Journal:  Magn Reson Med       Date:  2012-05-03       Impact factor: 4.668

8.  All-systolic non-ECG-gated myocardial perfusion MRI: Feasibility of multi-slice continuous first-pass imaging.

Authors:  Behzad Sharif; Reza Arsanjani; Rohan Dharmakumar; C Noel Bairey Merz; Daniel S Berman; Debiao Li
Journal:  Magn Reson Med       Date:  2015-06-06       Impact factor: 4.668

9.  Reduced field of view single-shot spiral perfusion imaging.

Authors:  Yang Yang; Li Zhao; Xiao Chen; Peter W Shaw; Jorge A Gonzalez; Frederick H Epstein; Craig H Meyer; Christopher M Kramer; Michael Salerno
Journal:  Magn Reson Med       Date:  2017-03-20       Impact factor: 4.668

10.  Free breathing three-dimensional late gadolinium enhancement cardiovascular magnetic resonance using outer volume suppressed projection navigators.

Authors:  Rajiv G Menon; G Wilson Miller; Jean Jeudy; Sanjay Rajagopalan; Taehoon Shin
Journal:  Magn Reson Med       Date:  2016-04-28       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.