Automated patient motion detection and correction in dynamic renal scintigraphy.

Russell D Folks1, Daya Manatunga, Ernest V Garcia, Andrew T Taylor.   

Abstract

UNLABELLED: Kidney motion during dynamic renal scintigraphy can cause errors in calculated renal function parameters. Our goal was to develop and validate algorithms to detect and correct patient motion.
METHODS: We retrospectively collected dynamic images from 86 clinical renal studies (42 women, 44 men), acquired using (99m)Tc-mercaptoacetyltriglycine (80 image frames [128 × 128 pixels; 3.2 mm/pixel]: twenty-four 2-s frames, sixteen 15-s frames, and forty 30-s frames). We simulated 10 types of vertical motion in each patient study, resulting in 860 image sets. Motion consisted of up or down shifts of magnitude 0.25 pixel to 4 pixels per frame and was either a gradual shift additive over multiple frames or an abrupt shift of one or more consecutive frames, with a later return to the start position. Additional horizontal motion was added to test its effect on detection of vertical motion. Original and shifted files were processed using a motion detection algorithm. Corrective shifts were applied, and the corrected and original (unshifted) images were compared pixel by pixel. Motion detected in the shifted data was also tabulated before and after correction of motion detected in the original data. A detected shift was considered correct if it was within 0.25 pixel of the simulated magnitude. Software was developed to facilitate visual review of all images and to summarize kidney motion and motion correction using linograms.
RESULTS: Overall detection of simulated shifts was 99% (3,068/3,096 frames) when the existing motion in the original images was first corrected. When the original motion was not corrected, overall shift detection was 76% (2,345/3,096 frames). For image frames in which no shift was added (and original motion was not corrected), 87% (27,142/31,132 frames) were correctly detected as having no shift. When corrected images were compared with original images, calculated count recovery was 100% for all shifts that were whole-pixel magnitudes. For fractional-pixel shifts, percentage count recovery varied from 52% to 73%. Visual review suggested that some original frames exhibited true patient motion.
CONCLUSION: The algorithm accurately detected motion as small as 0.25 pixel. Whole-pixel motion can be detected and corrected with high accuracy. Fractional-pixel motion can be detected and corrected, but with less accuracy. Importantly, by accurately identifying unshifted frames, the algorithm helps to prevent the introduction of errors during motion correction.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21565959      PMCID: PMC3104056          DOI: 10.2967/jnmt.110.081893

Source DB:  PubMed          Journal:  J Nucl Med Technol        ISSN: 0091-4916


  23 in total

1.  A motion correction algorithm for an image realignment programme useful for sequential radionuclide renography.

Authors:  A De Agostini; R Moretti; S Belletti; G Maira; G C Magri; M Bestagno
Journal:  Eur J Nucl Med       Date:  1992

2.  Respiratory motion of the heart: kinematics and the implications for the spatial resolution in coronary imaging.

Authors:  Y Wang; S J Riederer; R L Ehman
Journal:  Magn Reson Med       Date:  1995-05       Impact factor: 4.668

3.  Automatic motion correction for breast MR imaging.

Authors:  C S Zuo; A Jiang; B L Buff; T G Mahon; T Z Wong
Journal:  Radiology       Date:  1996-03       Impact factor: 11.105

4.  Use of cross-correlation function to detect patient motion during SPECT imaging.

Authors:  R L Eisner; T Noever; D Nowak; W Carlson; D Dunn; J Oates; K Cloninger; H A Liberman; R E Patterson
Journal:  J Nucl Med       Date:  1987-01       Impact factor: 10.057

5.  Effect of motion on thallium-201 SPECT studies: a simulation and clinical study.

Authors:  F M Prigent; M Hyun; D S Berman; A Rozanski
Journal:  J Nucl Med       Date:  1993-11       Impact factor: 10.057

6.  Dual-isotope motion correction technique for gated exercise scintigraphy.

Authors:  M W Groch; W D Erwin; D A Turner; J R Domnanovich
Journal:  J Nucl Med       Date:  1985-12       Impact factor: 10.057

7.  Effect of patient motion on tomographic myocardial perfusion imaging.

Authors:  J A Cooper; P H Neumann; B K McCandless
Journal:  J Nucl Med       Date:  1992-08       Impact factor: 10.057

8.  Correcting organ motion artifacts in x-ray CT medical imaging systems by adaptive processing. I. Theory.

Authors:  A C Dhanantwari; S Stergiopoulos; I Iakovidis
Journal:  Med Phys       Date:  2001-08       Impact factor: 4.071

9.  Motion correction of PET brain images through deconvolution: II. Practical implementation and algorithm optimization.

Authors:  N Raghunath; T L Faber; S Suryanarayanan; J R Votaw
Journal:  Phys Med Biol       Date:  2009-01-09       Impact factor: 3.609

10.  Assessment of 3D DCE-MRI of the kidneys using non-rigid image registration and segmentation of voxel time courses.

Authors:  Frank G Zöllner; Rosario Sance; Peter Rogelj; María J Ledesma-Carbayo; Jarle Rørvik; Andrés Santos; Arvid Lundervold
Journal:  Comput Med Imaging Graph       Date:  2009-01-09       Impact factor: 4.790

View more
  4 in total

1.  iRENEX: a clinically informed decision support system for the interpretation of ⁹⁹mTc-MAG3 scans to detect renal obstruction.

Authors:  Ernest V Garcia; Andrew Taylor; Russell Folks; Daya Manatunga; Raghuveer Halkar; Bital Savir-Baruch; Eva Dubovsky
Journal:  Eur J Nucl Med Mol Imaging       Date:  2012-05-30       Impact factor: 9.236

2.  SNMMI Procedure Standard/EANM Practice Guideline for Diuretic Renal Scintigraphy in Adults With Suspected Upper Urinary Tract Obstruction 1.0.

Authors:  Andrew T Taylor; David C Brandon; Diego de Palma; M Donald Blaufox; Emmanuel Durand; Belkis Erbas; Sandra F Grant; Andrew J W Hilson; Anni Morsing
Journal:  Semin Nucl Med       Date:  2018-03-16       Impact factor: 4.446

3.  99mTc-MAG3: Image Wisely.

Authors:  Andrew T Taylor; Russell D Folks; A K M Fazlur Rahman; Aruna Polsani; Eva V Dubovsky; Raghuveer Halkar; Amita Manatunga
Journal:  Radiology       Date:  2017-02-17       Impact factor: 11.105

Review 4.  Computer-assisted diagnosis in renal nuclear medicine: rationale, methodology, and interpretative criteria for diuretic renography.

Authors:  Andrew T Taylor; Ernest V Garcia
Journal:  Semin Nucl Med       Date:  2014-03       Impact factor: 4.446

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.