Literature DB >> 19135861

Assessment of 3D DCE-MRI of the kidneys using non-rigid image registration and segmentation of voxel time courses.

Frank G Zöllner1, Rosario Sance, Peter Rogelj, María J Ledesma-Carbayo, Jarle Rørvik, Andrés Santos, Arvid Lundervold.   

Abstract

We have applied automated image analysis methods in the assessment of human kidney perfusion based on 3D dynamic contrast-enhanced MRI data. This approach consists of non-rigid 3D image registration of the moving kidney followed by k-means clustering of the voxel time courses with split between left and right kidney. This method was applied to four data sets acquired from healthy volunteers, using 1.5 T (2 exams) and 3 T scanners (2 exams). The proposed registration method reduced motion artifacts in the image time series and improved further analysis of the DCE-MRI data. The subsequent clustering to segment the kidney compartments was in agreement with manually delineations (similarity score of 0.96) in the same motion corrected images. The resulting mean intensity time curves clearly show the successive transition of contrast agent through kidney compartments (cortex, medulla, and pelvis). The proposed method for motion correction and kidney compartment segmentation might improve the validity and usefulness of further model-based pharmacokinetic analysis of kidney function in patients.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19135861     DOI: 10.1016/j.compmedimag.2008.11.004

Source DB:  PubMed          Journal:  Comput Med Imaging Graph        ISSN: 0895-6111            Impact factor:   4.790


  31 in total

1.  Estimating nonrigid motion from inconsistent intensity with robust shape features.

Authors:  Wenyang Liu; Dan Ruan
Journal:  Med Phys       Date:  2013-12       Impact factor: 4.071

2.  Performance of an efficient image-registration algorithm in processing MR renography data.

Authors:  Christopher C Conlin; Jeff L Zhang; Florian Rousset; Clement Vachet; Yangyang Zhao; Kathryn A Morton; Kristi Carlston; Guido Gerig; Vivian S Lee
Journal:  J Magn Reson Imaging       Date:  2015-07-14       Impact factor: 4.813

3.  Segmental kidney volumes measured by dynamic contrast-enhanced magnetic resonance imaging and their association with CKD in older people.

Authors:  Todd Woodard; Sigurdur Sigurdsson; John D Gotal; Alyssa A Torjesen; Lesley A Inker; Thor Aspelund; Gudny Eiriksdottir; Vilmundur Gudnason; Tamara B Harris; Lenore J Launer; Andrew S Levey; Gary F Mitchell
Journal:  Am J Kidney Dis       Date:  2014-07-10       Impact factor: 8.860

4.  Shape-based motion correction in dynamic contrast-enhanced MRI for quantitative assessment of renal function.

Authors:  Wenyang Liu; Kyunghyun Sung; Dan Ruan
Journal:  Med Phys       Date:  2014-12       Impact factor: 4.071

5.  Automatic 2D registration of renal perfusion image sequences by mutual information and adaptive prediction.

Authors:  Vincenzo Positano; Ilaria Bernardeschi; Virna Zampa; Martina Marinelli; Luigi Landini; Maria Filomena Santarelli
Journal:  MAGMA       Date:  2012-09-19       Impact factor: 2.310

6.  UMMPerfusion: an open source software tool towards quantitative MRI perfusion analysis in clinical routine.

Authors:  Frank G Zöllner; Gerald Weisser; Marcel Reich; Sven Kaiser; Stefan O Schoenberg; Steven P Sourbron; Lothar R Schad
Journal:  J Digit Imaging       Date:  2013-04       Impact factor: 4.056

7.  A semi-automated "blanket" method for renal segmentation from non-contrast T1-weighted MR images.

Authors:  Henry Rusinek; Jeremy C Lim; Nicole Wake; Jas-mine Seah; Elissa Botterill; Shawna Farquharson; Artem Mikheev; Ruth P Lim
Journal:  MAGMA       Date:  2015-10-29       Impact factor: 2.310

8.  Automated patient motion detection and correction in dynamic renal scintigraphy.

Authors:  Russell D Folks; Daya Manatunga; Ernest V Garcia; Andrew T Taylor
Journal:  J Nucl Med Technol       Date:  2011-05-12

9.  Measurement of murine kidney functional biomarkers using DCE-MRI: A multi-slice TRICKS technique and semi-automated image processing algorithm.

Authors:  Kai Jiang; Hui Tang; Prasanna K Mishra; Slobodan I Macura; Lilach O Lerman
Journal:  Magn Reson Imaging       Date:  2019-08-20       Impact factor: 2.546

Review 10.  MRI tools for assessment of microstructure and nephron function of the kidney.

Authors:  Luke Xie; Kevin M Bennett; Chunlei Liu; G Allan Johnson; Jeff Lei Zhang; Vivian S Lee
Journal:  Am J Physiol Renal Physiol       Date:  2016-09-14
View more