Literature DB >> 1634955

Effect of patient motion on tomographic myocardial perfusion imaging.

J A Cooper1, P H Neumann, B K McCandless.   

Abstract

We evaluated the effect of patient motion on inducing false-positive tomographic 201Tl myocardial perfusion studies. The effects of the angle of camera rotation at which movement occurs, the direction of movement and the distance of movement were studied. Movement was stimulated by shifting the raw data from normal motion-free 201Tl tomographic myocardial perfusion studies. The visual detectability of motion artifact was evaluated with receiver-operating characteristic curve analysis. The clinical importance of patient movement was determined by measuring the incidence of quantitative bull's-eye abnormalities induced by motion. Visual artifacts were more detectable and quantitative abnormalities more frequent as the distance of movement increased. Artifacts from 3.25 mm of movement were not visually detectable. Artifacts from 6.5 mm of movement were visually detectable, but were infrequently clinically important. Movement of 13 mm or greater frequently caused quantitative abnormalities. Quantitative abnormalities from axial movement were more frequent than artifacts from lateral movement. Quantitative abnormalities were more frequent when the movement occurred at the beginning or end. We conclude that when patients move during 201Tl tomographic myocardial perfusion imaging, the incidence and character of false-positive results depend on the angle of camera rotation at which the movement occurs, the direction of the movement and distance of the movement.

Entities:  

Mesh:

Substances:

Year:  1992        PMID: 1634955

Source DB:  PubMed          Journal:  J Nucl Med        ISSN: 0161-5505            Impact factor:   10.057


  44 in total

Review 1.  Effect of motion on cardiac SPECT imaging: recognition and motion correction.

Authors:  J Fitzgerald; P G Danias
Journal:  J Nucl Cardiol       Date:  2001 Nov-Dec       Impact factor: 5.952

2.  Use of rotating (cine) planar projection images in the interpretation of a tomographic myocardial perfusion study.

Authors:  R C Hendel; R J Gibbons; T M Bateman
Journal:  J Nucl Cardiol       Date:  1999 Mar-Apr       Impact factor: 5.952

3.  Single photon-emission computed tomography.

Authors:  Thomas A Holly; Brian G Abbott; Mouaz Al-Mallah; Dennis A Calnon; Mylan C Cohen; Frank P DiFilippo; Edward P Ficaro; Michael R Freeman; Robert C Hendel; Diwakar Jain; Scott M Leonard; Kenneth J Nichols; Donna M Polk; Prem Soman
Journal:  J Nucl Cardiol       Date:  2010-10       Impact factor: 5.952

4.  A study to quantify the effect of patient motion and develop methods to detect and correct for motion during myocardial perfusion imaging on a CZT solid-state dedicated cardiac camera.

Authors:  Shelley Redgate; David C Barber; John W Fenner; Abdallah Al-Mohammad; Jonathon C Taylor; Michael B Hanney; Wendy B Tindale
Journal:  J Nucl Cardiol       Date:  2015-12-18       Impact factor: 5.952

5.  Limited-angle effect compensation for respiratory binned cardiac SPECT.

Authors:  Wenyuan Qi; Yongyi Yang; Miles N Wernick; P Hendrik Pretorius; Michael A King
Journal:  Med Phys       Date:  2016-01       Impact factor: 4.071

6.  Moving ahead with CZT technology.

Authors:  Dominik C Benz; Ronny R Buechel
Journal:  J Nucl Cardiol       Date:  2015-11-10       Impact factor: 5.952

7.  Use of three-dimensional Gaussian interpolation in the projector/backprojector pair of iterative reconstruction for compensation of known rigid-body motion in SPECT.

Authors:  Bing Feng; Howard C Gifford; Richard D Beach; Guido Boening; Michael A Gennert; Michael A King
Journal:  IEEE Trans Med Imaging       Date:  2006-07       Impact factor: 10.048

Review 8.  Optimal SPECT processing and display: making bad studies look good to get the right answer.

Authors:  Dalia Y Ibrahim; Frank P DiFilippo; Jeremy E Steed; Manuel D Cerqueira
Journal:  J Nucl Cardiol       Date:  2006-11       Impact factor: 5.952

9.  Myocardial perfusion and function single photon emission computed tomography.

Authors:  Christopher L Hansen; Richard A Goldstein; Daniel S Berman; Keith B Churchwell; C David Cooke; James R Corbett; S James Cullom; Seth T Dahlberg; James R Galt; Ravi K Garg; Gary V Heller; Mark C Hyun; Lynne L Johnson; April Mann; Benjamin D McCallister; Raymond Taillefer; R Parker Ward; John J Mahmarian
Journal:  J Nucl Cardiol       Date:  2006-11       Impact factor: 5.952

Review 10.  Myocardial perfusion and function: single photon emission computed tomography.

Authors:  Christopher L Hansen; Richard A Goldstein; Olakunle O Akinboboye; Daniel S Berman; Elias H Botvinick; Keith B Churchwell; C David Cooke; James R Corbett; S James Cullom; Seth T Dahlberg; Regina S Druz; Edward P Ficaro; James R Galt; Ravi K Garg; Guido Germano; Gary V Heller; Milena J Henzlova; Mark C Hyun; Lynne L Johnson; April Mann; Benjamin D McCallister; Robert A Quaife; Terrence D Ruddy; Senthil N Sundaram; Raymond Taillefer; R Parker Ward; John J Mahmarian
Journal:  J Nucl Cardiol       Date:  2007 Nov-Dec       Impact factor: 5.952

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.