Literature DB >> 11870850

Half-Fourier single-shot STEAM MRI.

Jürgen Finsterbusch1, Jens Frahm.   

Abstract

As a high-speed imaging technique based on stimulated echoes single-shot STEAM MRI is insensitive to chemical shift artifacts and magnetic susceptibility differences. The achievable signal-to-noise ratio (SNR) is limited by the fact that high flip angles of the read-out excitation pulses cause a steep decay of the stimulated echo train and therefore degrade the point-spread function of the resulting image. The present work investigates the use of half-Fourier phase encoding which weakens the flip angle constraint by reducing the number of necessary excitations. Single-shot STEAM MRI of the normal human brain at 2.0 T demonstrates that half-Fourier versions either reduce the measurement time by almost a factor of two without sacrificing the SNR or increase the SNR by about 40% while keeping the measurement time constant. Copyright 2002 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2002        PMID: 11870850     DOI: 10.1002/mrm.10090

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  7 in total

1.  Determination of three-dimensional muscle architectures: validation of the DTI-based fiber tractography method by manual digitization.

Authors:  P Schenk; T Siebert; P Hiepe; D Güllmar; J R Reichenbach; C Wick; R Blickhan; M Böl
Journal:  J Anat       Date:  2013-05-16       Impact factor: 2.610

2.  Murine diffusion imaging using snapshot interleaved EPI acquisition at 7T.

Authors:  David N Guilfoyle; Scott Gerum; Jan Hrabe
Journal:  J Neurosci Methods       Date:  2011-04-30       Impact factor: 2.390

3.  In vivo diffusion tensor mapping of the brain of squirrel monkey, rat, and mouse using single-shot STEAM MRI.

Authors:  S Boretius; O Natt; T Watanabe; R Tammer; L Ehrenreich; J Frahm; T Michaelis
Journal:  MAGMA       Date:  2004-12-01       Impact factor: 2.310

4.  Differentiation of typical and atypical Parkinson syndromes by quantitative MR imaging.

Authors:  N K Focke; G Helms; P M Pantel; S Scheewe; M Knauth; C G Bachmann; J Ebentheuer; P Dechent; W Paulus; C Trenkwalder
Journal:  AJNR Am J Neuroradiol       Date:  2011-10-13       Impact factor: 3.825

5.  A comparison and evaluation of reduced-FOV methods for multi-slice 7T human imaging.

Authors:  Christopher J Wargo; Jay Moore; John C Gore
Journal:  Magn Reson Imaging       Date:  2013-07-25       Impact factor: 2.546

6.  Rapid radiofrequency field mapping in vivo using single-shot STEAM MRI.

Authors:  Gunther Helms; Jürgen Finsterbusch; Nikolaus Weiskopf; Peter Dechent
Journal:  Magn Reson Med       Date:  2008-09       Impact factor: 4.668

7.  Magnetic resonance elastography of the human brain using a multiphase DENSE acquisition.

Authors:  Johannes Strasser; Michaela Tanja Haindl; Rudolf Stollberger; Franz Fazekas; Stefan Ropele
Journal:  Magn Reson Med       Date:  2019-01-29       Impact factor: 4.668

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.