Comparison of the fracture torque of different Brazilian mini-implants.

Guilherme Machado Alvares de Lima1, Mário Sérgio Soares, Sibele Sarti Penha, Marcelo Munhóes Romano.   

Abstract

This study evaluated fracture torque by torsion, in relation to the length and diameter of orthodontic mini-implants, to demonstrate their viability for clinical and experimental use based on the torque recommended by the manufacturers. The fractures at the moment of insertion, whose incidence in the literature is around 4%, are principally due to excessive force and the inability of the implant to resist rotational forces. Thirty orthodontic mini-implants of three commercial brands available in Brazil (Neodent 1.6 x 9 mm, Dentoflex 1.6 x 9 mm and Kopp 1.6 x 9 mm) were attached to a device made specifically for this research, leaving the mini-implants with sufficient stability. The miniimplants were submitted to torsion torque, using a digital torque wrench, until their breaking point. The values obtained with the test were submitted to analysis of variance and the Tukey test. The mean values of mini-implant ruptures were 26 N.cm for group A (Dentoflex), 25.4 N. cm for group B (Kopp) and 32.8 N.cm for group C (Neodent). From the Tukey test we could observe that the relationships between the means of the Dentoflex and Neodent groups, and between the Kopp and Neodent groups, were significant. Between the Dentoflex and Kopp groups, significance was nonexistent. All the values found in our research for fracture torque were higher than the limits recommended by the manufacturers for clinical use in orthodontics. The highest values were found in the Neodent group.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21537637     DOI: 10.1590/s1806-83242011000200004

Source DB:  PubMed          Journal:  Braz Oral Res        ISSN: 1806-8324


  5 in total

1.  Accuracy of torque-limiting devices used for mini-implant placement--an in vitro study.

Authors:  Alexander Pauls; Manuel Nienkemper; Dieter Drescher
Journal:  J Orofac Orthop       Date:  2013-03-08       Impact factor: 1.938

2.  Experimental investigation of the fracture torque of orthodontic anchorage screws.

Authors:  Susanne Reimann; Mustafa Ayubi; Fraser McDonald; Christoph Bourauel
Journal:  J Orofac Orthop       Date:  2016-04-20       Impact factor: 1.938

3.  Insertion torque versus mechanical resistance of mini-implants inserted in different cortical thickness.

Authors:  Renata Faria Santos; Antonio Carlos de Oliveira Ruellas; Daniel Jogaib Fernandes; Carlos Nelson Elias
Journal:  Dental Press J Orthod       Date:  2014 May-Jun

4.  Effects of insertion angle and implant thread type on the fracture properties of orthodontic mini-implants during insertion.

Authors:  Il-Sik Cho; Tae-Woo Kim; Sug-Joon Ahn; Il-Hyung Yang; Seung-Hak Baek
Journal:  Angle Orthod       Date:  2012-12-10       Impact factor: 2.079

Review 5.  A Mini-review on the Effect of Mini-implants on Contemporary Orthodontic Science.

Authors:  Saeid Nosouhian; Mansour Rismanchian; Roya Sabzian; Elham Shadmehr; Hamid Badrian; Amin Davoudi
Journal:  J Int Oral Health       Date:  2015
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.