PURPOSE: Noise characterization through estimation of the noise power spectrum (NPS) is a central component of the evaluation of digital x-ray systems. Extensive works have been conducted to achieve accurate and precise measurement of NPS. One approach to improve the accuracy of the NPS measurement is to reduce the statistical variance of the NPS results by involving more data samples. However, this method is based on the assumption that the noise in a radiographic image is arising from stochastic processes. In the practical data, the artifactuals always superimpose on the stochastic noise as low-frequency background trends and prevent us from achieving accurate NPS. The purpose of this study was to investigate an appropriate background detrending technique to improve the accuracy of NPS estimation for digital x-ray systems.
METHODS: In order to achieve the optimal background detrending technique for NPS estimate, four methods for artifactuals removal were quantitatively studied and compared: (1) Subtraction of a low-pass-filtered version of the image, (2) subtraction of a 2-D first-order fit to the image, (3) subtraction of a 2-D second-order polynomial fit to the image, and (4) subtracting two uniform exposure images. In addition, background trend removal was separately applied within original region of interest or its partitioned sub-blocks for all four methods. The performance of background detrending techniques was compared according to the statistical variance of the NPS results and low-frequency systematic rise suppression.
RESULTS: Among four methods, subtraction of a 2-D second-order polynomial fit to the image was most effective in low-frequency systematic rise suppression and variances reduction for NPS estimate according to the authors' digital x-ray system. Subtraction of a low-pass-filtered version of the image led to NPS variance increment above low-frequency components because of the side lobe effects of frequency response of the boxcar filtering function. Subtracting two uniform exposure images obtained the worst result on the smoothness of NPS curve, although it was effective in low-frequency systematic rise suppression. Subtraction of a 2-D first-order fit to the image was also identified effective for background detrending, but it was worse than subtraction of a 2-D second-order polynomial fit to the image according to the authors' digital x-ray system.
CONCLUSIONS: As a result of this study, the authors verified that it is necessary and feasible to get better NPS estimate by appropriate background trend removal. Subtraction of a 2-D second-order polynomial fit to the image was the most appropriate technique for background detrending without consideration of processing time.

Mesh:

Year:  2011        PMID: 21520872     DOI: 10.1118/1.3556566

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  7 in total

1.  Basic imaging properties of an indirect flat-panel detector system employing irradiation side sampling (ISS) technology for chest radiography: comparison with a computed radiographic system.

Authors:  Nobukazu Tanaka; Yuki Yano; Hidetake Yabuuchi; Tsutomu Akasaka; Masayuki Sasaki; Masafumi Ohki; Junji Morishita
Journal:  Radiol Phys Technol       Date:  2012-11-10

2.  Investigation of optimum anti-scatter grid selection for digital radiography: physical imaging properties and detectability of low-contrast signals.

Authors:  Nobukazu Tanaka; Kentaro Naka; Aya Saito; Junji Morishita; Fukai Toyofuku; Masafumi Ohki; Yoshiharu Higashida
Journal:  Radiol Phys Technol       Date:  2012-08-08

3.  On the performance of the noise power spectrum from the gain-corrected radiography images.

Authors:  Dong Sik Kim; Eunae Lee
Journal:  J Med Imaging (Bellingham)       Date:  2018-03-30

4.  Fundamental study on quality assurance (QA) procedures for a real-time tumor tracking radiotherapy (RTRT) system from the viewpoint of imaging devices.

Authors:  Suguru Kimura; Naoki Miyamoto; Kenneth L Sutherland; Ryusuke Suzuki; Hiroki Shirato; Masayori Ishikawa
Journal:  J Appl Clin Med Phys       Date:  2021-06-02       Impact factor: 2.102

5.  Practical considerations for noise power spectra estimation for clinical CT scanners.

Authors:  Steven Dolly; Hsin-Chen Chen; Mark Anastasio; Sasa Mutic; Hua Li
Journal:  J Appl Clin Med Phys       Date:  2016-05-08       Impact factor: 2.102

6.  New adaptive statistical iterative reconstruction ASiR-V: Assessment of noise performance in comparison to ASiR.

Authors:  Paolo De Marco; Daniela Origgi
Journal:  J Appl Clin Med Phys       Date:  2018-01-24       Impact factor: 2.102

7.  Evaluation of three-dimensional iterative image reconstruction in C-arm-based interventional cone-beam CT: A phantom study in comparison with customary reconstruction technique.

Authors:  Shigeru Suzuki; Yoshiaki Katada; Tomoko Takayanagi; Haruto Sugawara; Takuya Ishikawa; Yuzo Yamamoto; Hiroo Wada
Journal:  Medicine (Baltimore)       Date:  2019-03       Impact factor: 1.889

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.