Randomized comparison of everolimus- and paclitaxel-eluting stents. 2-year follow-up from the SPIRIT (Clinical Evaluation of the XIENCE V Everolimus Eluting Coronary Stent System) IV trial.

Gregg W Stone1, Ali Rizvi, Krishnankutty Sudhir, William Newman, Robert J Applegate, Louis A Cannon, James T Maddux, Donald E Cutlip, Charles A Simonton, Poornima Sood, Dean J Kereiakes.   

Abstract

OBJECTIVES: We sought to determine whether the differences in outcomes present between everolimus-eluting stents (EES) and paclitaxel-eluting stents (PES) in the SPIRIT (Clinical Evaluation of the XIENCE V Everolimus Eluting Coronary Stent System) IV trial at 1 year were sustained with longer-term follow-up.
BACKGROUND: In the SPIRIT IV trial, patients undergoing percutaneous coronary intervention who were randomized to EES compared with PES experienced lower 1-year rates of target lesion failure (cardiac death, target vessel myocardial infarction [MI], or ischemia-driven target lesion revascularization [TLR]), with significant reductions in the individual rates of MI, TLR, and stent thrombosis.
METHODS: We prospectively randomized 3,687 patients with up to 3 noncomplex previously untreated native coronary artery lesions to EES versus PES at 66 U.S. sites. Follow-up through 2 years is complete in 3,578 patents (97.0%).
RESULTS: Treatment with EES compared with PES reduced the 2-year rates of TLF (6.9% vs. 9.9%, p = 0.003), all MI (2.5% vs. 3.9%, p = 0.02), Q-wave MI (0.1% vs. 0.8%, p = 0.002), stent thrombosis (0.4% vs. 1.2%, p = 0.008), and ischemia-driven TLR (4.5% vs. 6.9%, p = 0.004), with nonsignificantly different rates of all-cause and cardiac mortality. Between 1 year and 2 years, there were no significant differences in adverse event rates between the 2 stent types.
CONCLUSIONS: In the large-scale, prospective, multicenter, randomized SPIRIT IV trial, the benefits of EES compared with those of PES present at 1 year were sustained at 2 years.
Copyright © 2011 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21514084     DOI: 10.1016/j.jacc.2011.02.022

Source DB:  PubMed          Journal:  J Am Coll Cardiol        ISSN: 0735-1097            Impact factor:   24.094


  35 in total

1.  Twelve or 30 months of dual antiplatelet therapy after drug-eluting stents.

Authors:  Laura Mauri; Dean J Kereiakes; Robert W Yeh; Priscilla Driscoll-Shempp; Donald E Cutlip; P Gabriel Steg; Sharon-Lise T Normand; Eugene Braunwald; Stephen D Wiviott; David J Cohen; David R Holmes; Mitchell W Krucoff; James Hermiller; Harold L Dauerman; Daniel I Simon; David E Kandzari; Kirk N Garratt; David P Lee; Thomas K Pow; Peter Ver Lee; Michael J Rinaldi; Joseph M Massaro
Journal:  N Engl J Med       Date:  2014-11-16       Impact factor: 91.245

Review 2.  Restenosis after PCI. Part 2: prevention and therapy.

Authors:  J Wouter Jukema; Tarek A N Ahmed; Jeffrey J W Verschuren; Paul H A Quax
Journal:  Nat Rev Cardiol       Date:  2011-10-11       Impact factor: 32.419

Review 3.  Late stent thrombosis: the last remaining obstacle in coronary interventional therapy.

Authors:  Piera Capranzano; George Dangas
Journal:  Curr Cardiol Rep       Date:  2012-08       Impact factor: 2.931

4.  Clinical outcome after percutaneous treatment of de novo coronary bifurcation lesions using first or second generation of drug-eluting stents.

Authors:  Miroslaw Ferenc; Heinz Joachim Buettner; Michael Gick; Thomas Comberg; Juergen Rothe; Firas Khoury; Christian Valina; Aurel Toma; Piotr Kuebler; Florian Riede; Franz-Josef Neumann
Journal:  Clin Res Cardiol       Date:  2015-09-02       Impact factor: 5.460

Review 5.  Drug-eluting stents: the past, present, and future.

Authors:  Gregory Katz; Bhisham Harchandani; Binita Shah
Journal:  Curr Atheroscler Rep       Date:  2015-03       Impact factor: 5.113

6.  Clinical outcomes of different first- and second-generation drug-eluting stents in routine clinical practice: results from the prospective multicenter German DES.DE registry.

Authors:  Ibrahim Akin; Matthias Hochadel; Mohamed Abdel-Wahab; Jochen Senges; Gert Richardt; Steffen Schneider; Ulrich Tebbe; Karl-Heinz Kuck; Christoph A Nienaber
Journal:  Clin Res Cardiol       Date:  2013-02-06       Impact factor: 5.460

7.  Long-term performance of the second-generation cobalt-chromium sirolimus-eluting stents in real-world clinical practice: 3-year clinical outcomes from the prospective multicenter FOCUS registry.

Authors:  Feng Zhang; Ji'e Yang; Juying Qian; Lei Ge; Jun Zhou; Junbo Ge
Journal:  J Thorac Dis       Date:  2016-07       Impact factor: 2.895

8.  Risk stratification in acute coronary syndromes.

Authors:  Gabriele Pesarini; Francesco Santini; Giulia Geremia; Carlo Zivelonghi; Flavio Ribichini
Journal:  J Cardiovasc Transl Res       Date:  2011-12-02       Impact factor: 4.132

9.  Percutaneous coronary intervention should be guided by fractional flow reserve measurement.

Authors:  William F Fearon
Journal:  Circulation       Date:  2014-05-06       Impact factor: 29.690

10.  Biodegradable-Polymer Biolimus-Eluting Stents versus Durable-Polymer Everolimus-Eluting Stents at One-Year Follow-Up: A Registry-Based Cohort Study.

Authors:  Ehsan Parsa; Sepideh Saroukhani; Fereshteh Majlessi; Hamidreza Poorhosseini; Masoumeh Lofti-Tokaldany; Arash Jalali; Mojtaba Salarifar; Ebrahim Nematipour; Mohammad Alidoosti; Hassan Aghajani; Alireza Amirzadegan; Seyed Ebrahim Kassaian
Journal:  Tex Heart Inst J       Date:  2016-04-01