Literature DB >> 21512057

Application of MR mammography beyond local staging: is there a potential to accurately assess axillary lymph nodes? evaluation of an extended protocol in an initial prospective study.

Pascal A T Baltzer1, Matthias Dietzel, Hartmut P Burmeister, Ramy Zoubi, Mieczyslaw Gajda, Oumar Camara, Werner A Kaiser.   

Abstract

OBJECTIVE: The purpose of our study was to clinically test an extended MR mammography (MRM) protocol for combined local staging (T-staging) and locoregional staging (N-staging) of breast cancer within one single examination using a dedicated whole-body scanner. SUBJECTS AND METHODS: Fifty-six consecutive primary breast cancer patients without prior treatment underwent MRM and surgicopathological N-staging. The MRM protocol (10 minutes; axial T1-weighted gradient-recalled echo; dynamic contrast-enhanced; T2-weighted; turbo spin-echo) was extended to evaluate axillary lymph nodes (90 seconds; coronal T2-weighted HASTE; T1-weighted volumetric breath-hold examination; field of view, both axillae, supraclavicular nodes, and cervical nodes). A dedicated whole-body scanner was used. First, two experienced radiologists independently rated the presence of lymph node metastasis (present or absent, weighted kappa). Second, predefined descriptors were applied by both readers to differentiate lymph node status. These were statistically analyzed using univariate chi-square statistics, sensitivity and specificity, positive likelihood ratio, diagnostic odds ratio (OR), and multivariate statistics (binary logistic-regression, receiver operating characteristics, and chi-squared automatic interaction detection [CHAID] tree).
RESULTS: Most significant predictors (p < 0.001) of present metastasis were "irregular margin" (diagnostic OR, 14.0), "inhomogeneous cortex" (diagnostic OR, 8.4), "perifocal edema" (positive likelihood ratio, 100) and "asymmetry" (diagnostic OR, 19.5). CHAID tree identified "asymmetry" and "irregular margin" as significant predictors (adjusted-p < 0.05) for present metastasis (PPV: 100%), whereas absence of "asymmetry" and "homogeneous internal structure" were highly predictive of absent metastasis (negative predictive value, 94.3%). Combination of significant descriptors using binary logistic regression revealed an area under the receiver operating characteristic curve of 0.93 (p < 0.001). Interrater agreement was "almost-perfect" (κ = 0.95).
CONCLUSION: Combined T-staging and locoregional staging (N-staging) was possible within one imaging session using the proposed protocol. Despite a minimal increase in examination time, high diagnostic accuracy and excellent interrater reliability were achieved.

Entities:  

Mesh:

Year:  2011        PMID: 21512057     DOI: 10.2214/AJR.10.4889

Source DB:  PubMed          Journal:  AJR Am J Roentgenol        ISSN: 0361-803X            Impact factor:   3.959


  33 in total

1.  Usefulness of preoperative breast magnetic resonance imaging with a dedicated axillary sequence for the detection of axillary lymph node metastasis in patients with early ductal breast cancer.

Authors:  Hye Shin Ahn; Mijung Jang; Sun Mi Kim; Bo La Yun; Soo Hyun Lee
Journal:  Radiol Med       Date:  2019-08-17       Impact factor: 3.469

2.  Breast MRI at 7 Tesla with a bilateral coil and robust fat suppression.

Authors:  Ryan Brown; Pippa Storey; Christian Geppert; KellyAnne McGorty; Ana Paula Klautau Leite; James Babb; Daniel K Sodickson; Graham C Wiggins; Linda Moy
Journal:  J Magn Reson Imaging       Date:  2013-10-07       Impact factor: 4.813

3.  Fat suppression techniques for breast MRI: Dixon versus spectral fat saturation for 3D T1-weighted at 3 T.

Authors:  Anastasia Kalovidouri; Natacha Firmenich; Benedicte M A Delattre; Marlise Picarra; Christoph D Becker; Xavier Montet; Diomidis Botsikas
Journal:  Radiol Med       Date:  2017-06-22       Impact factor: 3.469

4.  Clinical utility of 18F-FDG-PET/MR for preoperative breast cancer staging.

Authors:  Diomidis Botsikas; Anastasia Kalovidouri; Minerva Becker; Michele Copercini; Dahila Amal Djema; Alexandre Bodmer; Sindy Monnier; Christoph D Becker; Xavier Montet; Benedicte M A Delattre; Osman Ratib; Valentina Garibotto; Claire Tabouret-Viaud
Journal:  Eur Radiol       Date:  2015-10-17       Impact factor: 5.315

5.  What is the diagnostic performance of 18-FDG-PET/MR compared to PET/CT for the N- and M- staging of breast cancer?

Authors:  Diomidis Botsikas; Ilias Bagetakos; Marlise Picarra; Ana Carolina Da Cunha Afonso Barisits; Sana Boudabbous; Xavier Montet; Giang Thanh Lam; Ismini Mainta; Anastasia Kalovidouri; Minerva Becker
Journal:  Eur Radiol       Date:  2018-09-28       Impact factor: 5.315

6.  MRI sequences for the detection of individual lymph nodes in regional breast radiotherapy planning.

Authors:  Tristan C F van Heijst; Bram van Asselen; Ruud M Pijnappel; Marissa Cloos-van Balen; Jan J W Lagendijk; Desirée van den Bongard; Mariëlle E P Philippens
Journal:  Br J Radiol       Date:  2016-05-10       Impact factor: 3.039

7.  Preoperative axillary nodal staging with ultrasound and magnetic resonance imaging: predictive values of quantitative and semantic features.

Authors:  Won Hwa Kim; Hye Jung Kim; So Mi Lee; Seung Hyun Cho; Kyung Min Shin; Sang Yub Lee; Jae Kwang Lim; Won Kee Lee
Journal:  Br J Radiol       Date:  2018-08-29       Impact factor: 3.039

8.  Fat suppression strategies in MR imaging of breast cancer at 3.0 T: comparison of the two-point Dixon technique and the frequency selective inversion method.

Authors:  Wakako Kaneko Mikami; Toshiki Kazama; Hirotaka Sato; Hajime Yokota; Takashi Higashide; Takuro Horikoshi; Ken Motoori; Yukimasa Miyazawa; Takeshi Nagashima; Takashi Uno
Journal:  Jpn J Radiol       Date:  2013-06-24       Impact factor: 2.374

9.  Suspicious axillary lymph nodes identified on clinical breast MRI in patients newly diagnosed with breast cancer: can quantitative features improve discrimination of malignant from benign?

Authors:  Habib Rahbar; Jane L Conlin; Sana Parsian; Wendy B DeMartini; Sue Peacock; Constance D Lehman; Savannah C Partridge
Journal:  Acad Radiol       Date:  2014-12-06       Impact factor: 3.173

10.  Breast MRI at 7 Tesla with a bilateral coil and T1-weighted acquisition with robust fat suppression: image evaluation and comparison with 3 Tesla.

Authors:  Ryan Brown; Pippa Storey; Christian Geppert; KellyAnne McGorty; Ana Paula Klautau Leite; James Babb; Daniel K Sodickson; Graham C Wiggins; Linda Moy
Journal:  Eur Radiol       Date:  2013-07-30       Impact factor: 5.315

View more