Literature DB >> 21498327

Factors influencing delay time and coronary arterial density during coronary angiography with DSCT.

Lijun Tang1, Xiaomei Zhu, Yi Xu, Tongfu Yu, Hai Xu, Jinhua Tang, Vikram Dogra, Dehang Wang.   

Abstract

BACKGROUND: CT angiography (CTA) plays an important role in diagnosing coronary arterial disease. Delay time and density of the coronary arteries related with patient-specific factors are essential for getting an optimal CTA image.
PURPOSE: To investigate various factors influencing delay time and coronary arterial density during coronary CTA with dual source CT.
MATERIAL AND METHODS: One hundred and sixteen consecutive subjects who underwent cardiac DSCT with retrospective ECG-gating were included. Factors including gender, age, height, weight, transversal cardiac diameter (TCD), transversal thoracic diameter (TTD), heart rate (HR), body surface area (BSA = [weight × height/3600](1/2)) and cardiothoracic ratio (CTR = TCD/TTD) were recorded, measured and calculated before administration of contrast media during coronary CT angiography. Delay time was determined as duration from the beginning of the injection to the density in the descending aorta at the level of right main pulmonary artery reaching a threshold of 100 HU. Coronary arterial density was measured at the mid portion of the right coronary artery. Regression analysis and stepwise regression analysis were used to investigate the influence of these factors on delay time and coronary arterial density.
RESULTS: Delay time decreased with an increasing HR and it was shorter in women than men. Delay time increased with an increasing TCD. Delay time could be predicted by the formula: DT = 16.651-0.110 × HR + 1.902 × gender + 0.394 × TCD (where DT is abbreviation for delay time, gender is 0 for women and 1 for men). Coronary arterial density decreased with an increasing HR and weight. Coronary arterial density could be predicted by the formula: CAD = 923.42-4.099 × HR-3.293 × weight (CAD = coronary arterial density). There was no relationship between the other factors mentioned above and delay time or coronary arterial density.
CONCLUSION: Delay time is influenced by HR, gender and TCD. Coronary arterial density also changes with HR and weight. So HR, gender, TCD and weight can be used to adjust flow rate and dosage of contrast media before administration of contrast media during coronary CT angiography.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21498327     DOI: 10.1258/ar.2010.090465

Source DB:  PubMed          Journal:  Acta Radiol        ISSN: 0284-1851            Impact factor:   1.990


  6 in total

1.  Shorter delay time reduces interpatient variability in coronary enhancement in coronary CT angiography using the bolus tracking method with 320-row CT.

Authors:  Nobuo Tomizawa; Takeshi Nojo; Masaaki Akahane; Rumiko Torigoe; Shigeru Kiryu; Kuni Ohtomo
Journal:  Int J Cardiovasc Imaging       Date:  2012-04-22       Impact factor: 2.357

2.  Contrast material injection protocol with the flow rate adjusted to the heart rate for dual source CT coronary angiography.

Authors:  Xiaomei Zhu; Wenping Chen; Mei Li; Yi Xu; Hai Xu; Yinsu Zhu; Dehang Wang; Lijun Tang
Journal:  Int J Cardiovasc Imaging       Date:  2011-10-04       Impact factor: 2.357

3.  Compact-bolus dynamic CT protocol with a test bolus technique in 64-MDCT coronary angiography: comparison of fixed injection rate and duration protocol.

Authors:  Masafumi Kidoh; Takeshi Nakaura; Kazuo Awai; Daisuke Utsunomiya; Naritsugu Sakaino; Kazunori Harada; Shouzaburou Uemura; Yasuyuki Yamashita
Journal:  Jpn J Radiol       Date:  2012-11-30       Impact factor: 2.374

4.  The influence of cardiac function on coronary arterial enhancement at coronary computed tomography angiography: A cross-sectional study.

Authors:  Maryam Moradi; Peiman Hashemi; Mohammad Momeni
Journal:  J Res Med Sci       Date:  2016-12-26       Impact factor: 1.852

5.  Coronary angiography using second-generation dual source computed tomography: Feasibility of low dose and low flow rate to achieve appropriate individual contrast enhancement using a test bolus-based contrast medium protocol-A CONSORT compliant article.

Authors:  Xiaomei Zhu; Yusheng Yu; Dinghu Xu; Hong Zhang; Lijun Tang
Journal:  Medicine (Baltimore)       Date:  2018-07       Impact factor: 1.889

6.  Low dose contrast media in step-and-shoot coronary angiography with third-generation dual-source computed tomography: feasibility of using 30 mL of contrast media in patients with body surface area <1.7 m2.

Authors:  Liang Jin; Bing Jie; Yiyi Gao; An'qi Jiang; Tingwen Weng; Ming Li
Journal:  Quant Imaging Med Surg       Date:  2021-06
  6 in total