Literature DB >> 21145554

Peak capacity optimization in comprehensive two dimensional liquid chromatography: a practical approach.

Haiwei Gu1, Yuan Huang, Peter W Carr.   

Abstract

In this work we develop a practical approach to optimization in comprehensive two dimensional liquid chromatography (LC x LC) which incorporates the important under-sampling correction and is based on the previously developed gradient implementation of the Poppe approach to optimizing peak capacity. The Poppe method allows the determination of the column length, flow rate as well as initial and final eluent compositions that maximize the peak capacity at a given gradient time. It was assumed that gradient elution is applied in both dimensions and that various practical constraints are imposed on both the initial and final mobile phase composition in the first dimension separation. It was convenient to consider four different classes of solute sets differing in their retention properties. The major finding of this study is that the under-sampling effect is very important and causes some unexpected results including the important counter-intuitive observation that under certain conditions the optimum effective LC x LC peak capacity is obtained when the first dimension is deliberately run under sub-optimal conditions. In addition, we found that the optimum sampling rate in this study is rather slower than reported in previous studies and that it increases with longer first dimension gradient times.
Copyright © 2010 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 21145554      PMCID: PMC3034304          DOI: 10.1016/j.chroma.2010.10.096

Source DB:  PubMed          Journal:  J Chromatogr A        ISSN: 0021-9673            Impact factor:   4.759


  33 in total

1.  Identification of the factors that influence the reproducibility of chromatographic retention data.

Authors:  A Felinger; M Kele; G Guiochon
Journal:  J Chromatogr A       Date:  2001-04-13       Impact factor: 4.759

Review 2.  Recent progress in online, comprehensive two-dimensional high-performance liquid chromatography for non-proteomic applications.

Authors:  Dwight R Stoll
Journal:  Anal Bioanal Chem       Date:  2010-04-06       Impact factor: 4.142

3.  Orthogonality of separation in two-dimensional liquid chromatography.

Authors:  Martin Gilar; Petra Olivova; Amy E Daly; John C Gebler
Journal:  Anal Chem       Date:  2005-10-01       Impact factor: 6.986

4.  A graphical method for understanding the kinetics of peak capacity production in gradient elution liquid chromatography.

Authors:  Xiaoli Wang; Dwight R Stoll; Peter W Carr; Peter J Schoenmakers
Journal:  J Chromatogr A       Date:  2006-06-13       Impact factor: 4.759

5.  Calculating optimal modulation periods to maximize the peak capacity in two-dimensional HPLC.

Authors:  Kanta Horie; Hiroshi Kimura; Tohru Ikegami; Akira Iwatsuka; Nabil Saad; Oliver Fiehn; Nobuo Tanaka
Journal:  Anal Chem       Date:  2007-04-17       Impact factor: 6.986

6.  Effect of first-dimension undersampling on effective peak capacity in comprehensive two-dimensional separations.

Authors:  Joe M Davis; Dwight R Stoll; Peter W Carr
Journal:  Anal Chem       Date:  2007-12-13       Impact factor: 6.986

7.  Generation and limitations of peak capacity in online two-dimensional liquid chromatography.

Authors:  Krisztián Horváth; Jacob N Fairchild; Georges Guiochon
Journal:  Anal Chem       Date:  2009-05-15       Impact factor: 6.986

8.  Optimization of two-dimensional gradient liquid chromatography separations.

Authors:  Petr Cesla; Tomás Hájek; Pavel Jandera
Journal:  J Chromatogr A       Date:  2008-09-04       Impact factor: 4.759

Review 9.  Sample dimensionality: a predictor of order-disorder in component peak distribution in multidimensional separation.

Authors:  J C Giddings
Journal:  J Chromatogr A       Date:  1995-05-26       Impact factor: 4.759

10.  Equation for peak capacity estimation in two-dimensional liquid chromatography.

Authors:  Xiaoping Li; Dwight R Stoll; Peter W Carr
Journal:  Anal Chem       Date:  2009-01-15       Impact factor: 6.986

View more
  5 in total

1.  An experimental study of sampling time effects on the resolving power of on-line two-dimensional high performance liquid chromatography.

Authors:  Yuan Huang; Haiwei Gu; Marcelo Filgueira; Peter W Carr
Journal:  J Chromatogr A       Date:  2011-04-12       Impact factor: 4.759

2.  Effect of first dimension phase selectivity in online comprehensive two dimensional liquid chromatography (LC×LC).

Authors:  Haiwei Gu; Yuan Huang; Marcelo Filgueira; Peter W Carr
Journal:  J Chromatogr A       Date:  2011-07-24       Impact factor: 4.759

3.  Phytochemical Characterization of Rhus coriaria L. Extracts by Headspace Solid-Phase Micro Extraction Gas Chromatography, Comprehensive Two-Dimensional Liquid Chromatography, and Antioxidant Activity Evaluation.

Authors:  Katia Arena; Emanuela Trovato; Francesco Cacciola; Ludovica Spagnuolo; Elisa Pannucci; Paolo Guarnaccia; Luca Santi; Paola Dugo; Luigi Mondello; Laura Dugo
Journal:  Molecules       Date:  2022-03-07       Impact factor: 4.411

4.  Determination of the Metabolite Content of Brassica juncea Cultivars Using Comprehensive Two-Dimensional Liquid Chromatography Coupled with a Photodiode Array and Mass Spectrometry Detection.

Authors:  Katia Arena; Francesco Cacciola; Laura Dugo; Paola Dugo; Luigi Mondello
Journal:  Molecules       Date:  2020-03-09       Impact factor: 4.411

5.  Combination of strong anion exchange liquid chromatography with microchip capillary electrophoresis sodium dodecyl sulfate for rapid two-dimensional separations of complex protein mixtures.

Authors:  Holger Zagst; Christin Elgert; Sönke Behrends; Hermann Wätzig
Journal:  Anal Bioanal Chem       Date:  2021-12-06       Impact factor: 4.142

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.