Literature DB >> 19150720

Approaches to comprehensive multidimensional liquid chromatography systems.

Jacob N Fairchild1, Krisztián Horváth, Georges Guiochon.   

Abstract

This work compares the performance of the three different schemes implementing two-dimensional liquid chromatography (2D-LC) in terms of the peak capacity that they can generate and of the time that they need to complete a two-dimensional analysis. We discuss in detail how time is spent in these two-dimensional liquid chromatography x liquid chromatography (LC x LC) schemes and how to compare them. Keeping constant the characteristics of the first-dimension separation, we systematically varied those of the second-dimension separation and of its coupling to the first-dimension. In the process, five systems were created, based on the principles of the three known implementations of comprehensive 2D-LC. This work demonstrates an original method for the selection of the best comprehensive 2D-LC approach, depending on the desired peak capacity and on time constraints. The decision to use a 2D-LC method arises from the need to achieve a given resolution (i.e., a target peak capacity) within as short a time as possible or to reach the highest possible resolution in a given analysis time. Using the most appropriate schemes, we suggest how it is realistically possible to generate peak capacities ranging from 266 in just over 20 min or about 2800 in 2.3 h. When the time available for a two-dimensional separation is very short and the desired peak capacity cannot be achieved in 1D-LC, an on-line 2D-LC approach is unquestionably best. However, if a longer analysis time is acceptable, a 10-fold increase in the peak capacity can be obtained at the cost of a mere 7-fold increase in total analysis time.

Mesh:

Year:  2008        PMID: 19150720     DOI: 10.1016/j.chroma.2008.12.073

Source DB:  PubMed          Journal:  J Chromatogr A        ISSN: 0021-9673            Impact factor:   4.759


  5 in total

1.  An experimental study of sampling time effects on the resolving power of on-line two-dimensional high performance liquid chromatography.

Authors:  Yuan Huang; Haiwei Gu; Marcelo Filgueira; Peter W Carr
Journal:  J Chromatogr A       Date:  2011-04-12       Impact factor: 4.759

Review 2.  Multi-dimensional liquid chromatography in proteomics--a review.

Authors:  Xiang Zhang; Aiqin Fang; Catherine P Riley; Mu Wang; Fred E Regnier; Charles Buck
Journal:  Anal Chim Acta       Date:  2010-02-06       Impact factor: 6.558

3.  Investigation of interpolation techniques for the reconstruction of the first dimension of comprehensive two-dimensional liquid chromatography-diode array detector data.

Authors:  Robert C Allen; Sarah C Rutan
Journal:  Anal Chim Acta       Date:  2011-06-23       Impact factor: 6.558

4.  A study of the precision and accuracy of peak quantification in comprehensive two-dimensional liquid chromatography in time.

Authors:  Dennis F Thekkudan; Sarah C Rutan; Peter W Carr
Journal:  J Chromatogr A       Date:  2010-04-21       Impact factor: 4.759

5.  Reversed-phase fused-core HPLC modeling of peptides.

Authors:  Matthias D'Hondt; Bert Gevaert; Sofie Stalmans; Sylvia Van Dorpe; Evelien Wynendaele; Kathelijne Peremans; Christian Burvenich; Bart De Spiegeleer
Journal:  J Pharm Anal       Date:  2012-11-30
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.