Literature DB >> 21483382

Bilateral Bispectral Index (BIS)-Vista as a measure of physiologic sleep in sleep-deprived anesthesiologists.

A A Dahaba1, J X Xue, G X Xu, Q H Liu, H Metzler.   

Abstract

BACKGROUND: Anesthesiologists who work extended hours exhibit acute and chronic sleep deprivation. The newest bilateral Bispectral Index (BIS)-Vista monitor offers new advantages over earlier models, which include a new algorithm (version 1.4). One possible useful application for BIS monitoring of physiological sleep would be in critically ill patients who almost uniformly suffer from sleep disruption and deprivation because they loose their circadian rhythm due to the harsh noisy environment of critical care units. Previous studies, which used earlier versions of the BIS monitor to depict normal physiologic sleep, produced widely conflicting results. The aim of our study was to assess whether the new BIS-Vista monitor would exhibit a temporal decline that corresponds to natural physiologic sleep stages in healthy sleep-deprived, post-call anesthesiologists.
METHODS: BIS-Vista sensors were bilaterally mounted, according to the manufacturer guidelines, onto the forehead of 10 healthy sleep-deprived volunteer anesthesiologists. Using the conventional Rechtschaffen and Kales criteria, BIS values during the awake, S1, S2, S3, S4, and rapid eye movement (REM) sleep stages were recorded.
RESULTS: Mean±SD BIS values during the awake, S1, S2, S3, S4, and REM sleep stages significantly declined for the left (96±2, 82±11, 73±10, 53±13, 43±11, 66±9) and right (97±2, 78±11, 69±9, 50±10, 39±13, 61±14) hemispheres respectively. There were no significant interhemispheric differences in BIS values over time (two-way ANOVA). However, in one subject, the left and right BIS values were mostly discordant throughout the recordings.
CONCLUSION: We demonstrated that although the BIS-Vista monitor was neither designed nor validated for monitoring normal physiologic sleep, it depicted a temporal decline that corresponds to normal physiologic sleep stages in sleep-deprived anesthesiologists.

Entities:  

Mesh:

Year:  2010        PMID: 21483382

Source DB:  PubMed          Journal:  Minerva Anestesiol        ISSN: 0375-9393            Impact factor:   3.051


  15 in total

1.  Monitoring sleep depth: analysis of bispectral index (BIS) based on polysomnographic recordings and sleep deprivation.

Authors:  Sandra Giménez; Sergio Romero; Joan Francesc Alonso; Miguel Ángel Mañanas; Anna Pujol; Pilar Baxarias; Rosa Maria Antonijoan
Journal:  J Clin Monit Comput       Date:  2015-11-14       Impact factor: 2.502

2.  Evaluation of acoustic characteristics of snoring sounds obtained during drug-induced sleep endoscopy.

Authors:  Michael Herzog; Sebastian Plößl; Alexander Glien; Beatrice Herzog; Christian Rohrmeier; Thomas Kühnel; Stefan Plontke; Patrick Kellner
Journal:  Sleep Breath       Date:  2014-11-27       Impact factor: 2.816

3.  Utility of the bispectral index for assessing natural physiological sleep stages in children and young adults.

Authors:  Mohamed-Rida Benissa; Sonia Khirani; Sarah Hartley; Annie Adala; Adriana Ramirez; Marta Fernandez-Bolanos; Maria-Antonia Quera-Salva; Brigitte Fauroux
Journal:  J Clin Monit Comput       Date:  2015-10-29       Impact factor: 2.502

4.  Depth-dependent changes of obstruction patterns under increasing sedation during drug-induced sedation endoscopy: results of a German monocentric clinical trial.

Authors:  Patrick Kellner; Beatrice Herzog; Sebastian Plößl; Christian Rohrmeier; Thomas Kühnel; Ramona Wanzek; Stefan Plontke; Michael Herzog
Journal:  Sleep Breath       Date:  2016-04-25       Impact factor: 2.816

5.  Age progression from vicenarians (20-29 year) to nonagenarians (90-99 year) among a population pharmacokinetic/pharmacodynamic (PopPk-PD) covariate analysis of propofol-bispectral index (BIS) electroencephalography.

Authors:  Ashraf A Dahaba; Zhaoyang Xiao; Xiaoling Zhu; Hailong Dong; Lize Xiong; Peter Rehak; Sieglinde Zelzer; Kun Wang; Gilbert Reibnegger
Journal:  J Pharmacokinet Pharmacodyn       Date:  2020-02-25       Impact factor: 2.745

6.  Changes in the first postoperative night bispectral index of patients after thyroidectomy with different types of primary anesthetic management: a randomized controlled trial.

Authors:  Wen-Fei Tan; Zhi-Lin Wang; Hong Ma; Feng Jin; Huang-Wei Lu
Journal:  J Clin Monit Comput       Date:  2017-01-12       Impact factor: 2.502

Review 7.  [Drug-induced sedation endoscopy-quo vadis? : Review and outlook].

Authors:  M Herzog; J T Maurer
Journal:  HNO       Date:  2017-02       Impact factor: 1.284

8.  Depth of sedation during drug induced sedation endoscopy monitored by BiSpectral Index® and Cerebral State Index®.

Authors:  Michael Herzog; Mathias Rudzki; Sebastian Plößl; Stefan Plontke; Patrick Kellner
Journal:  Sleep Breath       Date:  2020-08-28       Impact factor: 2.816

9.  Snoring Sounds Predict Obstruction Sites and Surgical Response in Patients with Obstructive Sleep Apnea Hypopnea Syndrome.

Authors:  Li-Ang Lee; Yu-Lun Lo; Jen-Fang Yu; Gui-She Lee; Yung-Lun Ni; Ning-Hung Chen; Tuan-Jen Fang; Chung-Guei Huang; Wen-Nuan Cheng; Hsueh-Yu Li
Journal:  Sci Rep       Date:  2016-07-29       Impact factor: 4.379

10.  Preoperative versus postoperative ultrasound-guided rectus sheath block for improving pain, sleep quality and cytokine levels of patients with open midline incisions undergoing transabdominal gynaecological operation: study protocol for a randomised controlled trial.

Authors:  Feng Jin; Xiao-Qian Li; Wen-Fei Tan; Hong Ma; Huang-Wei Lu
Journal:  Trials       Date:  2015-12-10       Impact factor: 2.279

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.