Literature DB >> 26515742

Utility of the bispectral index for assessing natural physiological sleep stages in children and young adults.

Mohamed-Rida Benissa1, Sonia Khirani2,3, Sarah Hartley4, Annie Adala4, Adriana Ramirez5,6, Marta Fernandez-Bolanos5, Maria-Antonia Quera-Salva4, Brigitte Fauroux5,7,8.   

Abstract

Polysomnography (PSG) is the gold standard for the analysis of sleep architecture but is not always available in routine practice, as it is time consuming and cumbersome for patients. Bispectral index (BIS), developed to quantify the deepness of general anesthesia, may be used as a simplified tool to evaluate natural sleep depth. We objectively recorded sleep architecture in young patients using the latest BIS Vista monitor and correlated BIS values with PSG sleep stages in order to determine BIS thresholds. Patients, referred for the screening of sleep apnea/hypopnea syndrome or differential diagnosis of hypersomnia were recruited. Overnight PSG and BIS were performed simultaneously. BIS values were averaged for each sleep stage. Pre-sleep wakefulness (W) and wake after sleep onset (WASO) were also differentiated. BIS values were discarded for a signal quality index <90 %. ROC curves were plotted to discriminate sleep stages from each other. Twelve patients (5.7-29.3 years old) were included. Mean BIS values were 83 ± 8, 76 ± 12, 77 ± 11, 70 ± 10, 43 ± 10, and 75 ± 10 for W, WASO, N1, N2, N3 and R (REM) stages, respectively. BIS failed to distinguish W, WASO, N1 and R stages. BIS threshold that identified stage N2 was <73 (AUC = 0.784, p < 0.001) with low sensitivity (75 %) and poor specificity (64 %). BIS threshold that identified stage N3 was <55 (AUC = 0.964, p < 0.001) with an 87 %-sensitivity and a 93 %-specificity. BIS identified stage N3 with satisfactory sensitivity and specificity but is limited by its inability to distinguish REM sleep from wake. Further studies combining BIS with chin electromyogram and/or electrooculogram could be of interest.

Entities:  

Keywords:  Bispectral index; Natural sleep; Polysomnography; Sleep architecture; Sleep disorders

Mesh:

Year:  2015        PMID: 26515742     DOI: 10.1007/s10877-015-9800-x

Source DB:  PubMed          Journal:  J Clin Monit Comput        ISSN: 1387-1307            Impact factor:   2.502


  17 in total

Review 1.  Sleep-related breathing disorders in adults: recommendations for syndrome definition and measurement techniques in clinical research. The Report of an American Academy of Sleep Medicine Task Force.

Authors: 
Journal:  Sleep       Date:  1999-08-01       Impact factor: 5.849

2.  The bispectral index: a measure of depth of sleep?

Authors:  J W Sleigh; J Andrzejowski; A Steyn-Ross; M Steyn-Ross
Journal:  Anesth Analg       Date:  1999-03       Impact factor: 5.108

3.  Use of the BIS monitor to detect onset of naturally occurring sleep.

Authors:  Avery Tung; James P Lynch; Michael F Roizen
Journal:  J Clin Monit Comput       Date:  2002-01       Impact factor: 2.502

4.  Analysis of the bispectral index during natural sleep in children.

Authors:  Franca Benini; Manuela Trapanotto; Stefano Sartori; Anna Capretta; Daniela Gobber; Clementina Boniver; Franco Zacchello
Journal:  Anesth Analg       Date:  2005-09       Impact factor: 5.108

5.  Ontogenetic development of the human sleep-dream cycle.

Authors:  H P Roffwarg; J N Muzio; W C Dement
Journal:  Science       Date:  1966-04-29       Impact factor: 47.728

6.  Bilateral Bispectral Index (BIS)-Vista as a measure of physiologic sleep in sleep-deprived anesthesiologists.

Authors:  A A Dahaba; J X Xue; G X Xu; Q H Liu; H Metzler
Journal:  Minerva Anestesiol       Date:  2010-12-09       Impact factor: 3.051

Review 7.  Control of sleep and wakefulness.

Authors:  Ritchie E Brown; Radhika Basheer; James T McKenna; Robert E Strecker; Robert W McCarley
Journal:  Physiol Rev       Date:  2012-07       Impact factor: 37.312

8.  EEG sleep of normal healthy children. Part I: Findings using standard measurement methods.

Authors:  P A Coble; D J Kupfer; L S Taska; J Kane
Journal:  Sleep       Date:  1984       Impact factor: 5.849

9.  Bispectral index values and spectral edge frequency at different stages of physiologic sleep.

Authors:  Diederik Nieuwenhuijs; Emma L Coleman; Neil J Douglas; Gordon B Drummond; Albert Dahan
Journal:  Anesth Analg       Date:  2002-01       Impact factor: 5.108

10.  Electroencephalogram bispectral analysis predicts the depth of midazolam-induced sedation.

Authors:  J Liu; H Singh; P F White
Journal:  Anesthesiology       Date:  1996-01       Impact factor: 7.892

View more
  8 in total

Review 1.  Journal of clinical monitoring and computing 2016 end of year summary: anesthesia.

Authors:  Jan F A Hendrickx; Andre M De Wolf
Journal:  J Clin Monit Comput       Date:  2017-01-07       Impact factor: 2.502

2.  Changes in the first postoperative night bispectral index of patients after thyroidectomy with different types of primary anesthetic management: a randomized controlled trial.

Authors:  Wen-Fei Tan; Zhi-Lin Wang; Hong Ma; Feng Jin; Huang-Wei Lu
Journal:  J Clin Monit Comput       Date:  2017-01-12       Impact factor: 2.502

3.  Effects of ultrasound-guided stellate-ganglion block on sleep and regional cerebral oxygen saturation in patients undergoing breast cancer surgery: a randomized, controlled, double-blinded trial.

Authors:  Feng Jin; Xiao-Qian Li; Wen-Fei Tan; Hong Ma; Bo Fang; A-Yong Tian; Huang-Wei Lu
Journal:  J Clin Monit Comput       Date:  2017-10-17       Impact factor: 2.502

Review 4.  Measurements and status of sleep quality in patients with cancers.

Authors:  Dongying Chen; Zongyi Yin; Bo Fang
Journal:  Support Care Cancer       Date:  2017-10-23       Impact factor: 3.603

5.  Emulation of the BIS engine.

Authors:  Christopher W Connor
Journal:  J Clin Monit Comput       Date:  2021-03-19       Impact factor: 2.502

6.  A Forensic Disassembly of the BIS Monitor.

Authors:  Christopher W Connor
Journal:  Anesth Analg       Date:  2020-12       Impact factor: 6.627

7.  Effects of dexmedetomidine on sleep quality of patients after surgery without mechanical ventilation in ICU.

Authors:  Weina Lu; Qinghui Fu; Xiaoqian Luo; Shuiqiao Fu; Kai Hu
Journal:  Medicine (Baltimore)       Date:  2017-06       Impact factor: 1.889

8.  Preoperative versus postoperative ultrasound-guided rectus sheath block for improving pain, sleep quality and cytokine levels in patients with open midline incisions undergoing transabdominal gynecological surgery: a randomized-controlled trial.

Authors:  Feng Jin; Zhe Li; Wen-Fei Tan; Hong Ma; Xiao-Qian Li; Huang-Wei Lu
Journal:  BMC Anesthesiol       Date:  2018-02-09       Impact factor: 2.217

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.