PURPOSE OF REVIEW: This paper reviews recent evidence regarding the validity and reliability of acoustic voice analysis in routine clinical assessments. The current role of jitter and shimmer, the most-used indices, and how their clinical application might be improved are evaluated. RECENT FINDINGS: Even though the evidence is limited, acoustic analysis is widely used to assist differential diagnosis, documentation and evaluation of treatment for clinical voice disorders. Recent clinical data have not shown that jitter and shimmer are absolute or independent indices of voice pathology or perceptual hoarseness. However, in pretreatment and posttreatment comparisons within patients, acoustic analysis might have value as an outcome measure.Yet, the true value of clinical acoustic analysis might be masked by the confounding effects due to assessment system, gender, vowel and especially speaking voice intensity. SUMMARY: The validity of acoustic assessments in clinical applications remains unproven. Measurement reliability is still limited and might be greatly improved with relatively simple changes and consensus in measurement protocols and techniques. For instance, clinical assessment procedures and current normative values would have to be revised considering gender and vowel. Thus, future research might establish the validity and potential of clinical acoustic assessments.
PURPOSE OF REVIEW: This paper reviews recent evidence regarding the validity and reliability of acoustic voice analysis in routine clinical assessments. The current role of jitter and shimmer, the most-used indices, and how their clinical application might be improved are evaluated. RECENT FINDINGS: Even though the evidence is limited, acoustic analysis is widely used to assist differential diagnosis, documentation and evaluation of treatment for clinical voice disorders. Recent clinical data have not shown that jitter and shimmer are absolute or independent indices of voice pathology or perceptual hoarseness. However, in pretreatment and posttreatment comparisons within patients, acoustic analysis might have value as an outcome measure.Yet, the true value of clinical acoustic analysis might be masked by the confounding effects due to assessment system, gender, vowel and especially speaking voice intensity. SUMMARY: The validity of acoustic assessments in clinical applications remains unproven. Measurement reliability is still limited and might be greatly improved with relatively simple changes and consensus in measurement protocols and techniques. For instance, clinical assessment procedures and current normative values would have to be revised considering gender and vowel. Thus, future research might establish the validity and potential of clinical acoustic assessments.
Authors: Meike Brockmann-Bauser; Jarrad H Van Stan; Marilia Carvalho Sampaio; Joerg E Bohlender; Robert E Hillman; Daryush D Mehta Journal: J Voice Date: 2019-12-17 Impact factor: 2.009
Authors: Klaske E van Sluis; Lisette van der Molen; Rob J J H van Son; Frans J M Hilgers; Patrick A Bhairosing; Michiel W M van den Brekel Journal: Eur Arch Otorhinolaryngol Date: 2017-10-31 Impact factor: 2.503
Authors: Matthew R Naunheim; Jennifer B Dai; Benjamin J Rubinstein; Leanne Goldberg; Alan Weinberg; Mark S Courey Journal: Laryngoscope Investig Otolaryngol Date: 2019-12-17