Literature DB >> 21472460

Whole-body CT in polytrauma patients: effect of arm positioning on thoracic and abdominal image quality.

Christoph Karlo1, Ralph Gnannt, Thomas Frauenfelder, Sebastian Leschka, Martin Brüesch, Guido A Wanner, Hatem Alkadhi.   

Abstract

The purpose of this study is to assess the influence of different arm positioning techniques on thoracic and abdominal image quality and radiation dose of whole-body trauma CT (wbCT). One hundred and fifty polytrauma patients (104 male, mean age 47 ± 19) underwent wbCT with arms elevated above the head (group A, n=50), alongside the abdomen (group B, n=50), and on a pillow ventrally to the chest with both arms flexed (group C, n=50). Two blinded, independent observers measured image noise and rated image quality (scores 1-3) of the liver, aorta, spleen, spine, and lower lungs. Radiation dose parameters were noted, and the abdomens' anterior-posterior diameter and scan lengths were measured. Interreader agreements for image noise (r=0.86; p<0.001) and subjective image quality (k=0.71-0.84) were good. Noise was lower (p<0.05), image quality of the liver, aorta, spleen, and spine was higher, and radiation dose lower in group A than in groups B and C (p<0.001, each). Image quality of the spleen, liver, and aorta were higher in group C than in group B (p<0.05, each). No significant differences in scan length (p=0.61) were found among groups. Abdominal anterior-posterior diameter correlated significantly with noise (r=0.82; p<0.01) and dose (r=0.47; p<0.001). Estimated effective radiation doses were significantly (p<0.001) higher in groups B (21.2 mSv) and C (21.9 mSv) as compared to A (16.1 mSv). In wbCT for polytrauma patients, positioning of the arms above the head results in better image quality and lower radiation dose. Placing the flexed arms on a large pillow ventrally to the chest significantly improves image quality as compared to positioning alongside the abdomen.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21472460     DOI: 10.1007/s10140-011-0948-5

Source DB:  PubMed          Journal:  Emerg Radiol        ISSN: 1070-3004


  26 in total

1.  Radiation dose is reduced with a single-pass whole-body multi-detector row CT trauma protocol compared with a conventional segmented method: initial experience.

Authors:  Thomas Ptak; James T Rhea; Robert A Novelline
Journal:  Radiology       Date:  2003-12       Impact factor: 11.105

2.  Estimated radiation risks potentially associated with full-body CT screening.

Authors:  David J Brenner; Carl D Elliston
Journal:  Radiology       Date:  2004-07-23       Impact factor: 11.105

Review 3.  Computed tomography--an increasing source of radiation exposure.

Authors:  David J Brenner; Eric J Hall
Journal:  N Engl J Med       Date:  2007-11-29       Impact factor: 91.245

4.  Comparison of retrospectively ECG-gated and nongated MDCT of the chest in an emergency setting regarding workflow, image quality, and diagnostic certainty.

Authors:  Thomas Schertler; Thomas Glücker; Simon Wildermuth; Karl-Peter Jungius; Borut Marincek; Thomas Boehm
Journal:  Emerg Radiol       Date:  2005-11-09

5.  Whole body 16-row multislice CT in emergency room: effects of different protocols on scanning time, image quality and radiation exposure.

Authors:  Ezio Fanucci; Valeria Fiaschetti; Anna Rotili; Roberto Floris; Giovanni Simonetti
Journal:  Emerg Radiol       Date:  2006-12-20

6.  Whole-body multislice computed tomography (MSCT) improves trauma care in patients requiring surgery after multiple trauma.

Authors:  T E Wurmb; C Quaisser; H Balling; M Kredel; R Muellenbach; W Kenn; N Roewer; J Brederlau
Journal:  Emerg Med J       Date:  2010-07-20       Impact factor: 2.740

7.  A novel multiple-trauma CT-scanning protocol using patient repositioning.

Authors:  Hanno Hoppe; Peter Vock; Harald Marcel Bonel; Christoph Ozdoba; Jan Gralla
Journal:  Emerg Radiol       Date:  2006-10-13

8.  Influence of arm positioning on radiation dose for whole body computed tomography in trauma patients.

Authors:  Jörg Bayer; Gregor Pache; Peter C Strohm; Jörn Zwingmann; Philipp Blanke; Tobias Baumann; Norbert P Südkamp; Thorsten Hammer
Journal:  J Trauma       Date:  2011-04

9.  Effect of whole-body CT during trauma resuscitation on survival: a retrospective, multicentre study.

Authors:  Stefan Huber-Wagner; Rolf Lefering; Lars-Mikael Qvick; Markus Körner; Michael V Kay; Klaus-Jürgen Pfeifer; Maximilian Reiser; Wolf Mutschler; Karl-Georg Kanz
Journal:  Lancet       Date:  2009-03-25       Impact factor: 79.321

10.  Recurrent CT, cumulative radiation exposure, and associated radiation-induced cancer risks from CT of adults.

Authors:  Aaron Sodickson; Pieter F Baeyens; Katherine P Andriole; Luciano M Prevedello; Richard D Nawfel; Richard Hanson; Ramin Khorasani
Journal:  Radiology       Date:  2009-04       Impact factor: 11.105

View more
  20 in total

1.  Dose reduction in 64-row whole-body CT in multiple trauma: an optimized CT protocol with iterative image reconstruction on a gemstone-based scintillator.

Authors:  Lucas L Geyer; Markus Körner; Andreas Harrieder; Fabian G Mueck; Zsuzsanna Deak; Stefan Wirth; Ulrich Linsenmaier
Journal:  Br J Radiol       Date:  2016-02-08       Impact factor: 3.039

2.  Rapid imaging protocol in trauma: a whole-body dual-source CT scan.

Authors:  Anto Sedlic; Christina M Chingkoe; David K Tso; Sandro Galea-Soler; Savvas Nicolaou
Journal:  Emerg Radiol       Date:  2013-06-21

Review 3.  Imaging in forensic radiology: an illustrated guide for postmortem computed tomography technique and protocols.

Authors:  Patricia M Flach; Dominic Gascho; Wolf Schweitzer; Thomas D Ruder; Nicole Berger; Steffen G Ross; Michael J Thali; Garyfalia Ampanozi
Journal:  Forensic Sci Med Pathol       Date:  2014-04-11       Impact factor: 2.007

4.  MDCT diagnosis of post-traumatic hepatic arterio-portal fistulas.

Authors:  Cuong T Nguyen; Coung Nguyen; Nitima Saksobhavivat; Nitima Saksobahavivat; Kathirkamanathan Shanmuganathan; Scott D Steenburg; Scott Steenburg; Fred M Moeslein; Fred Moeslein; Stuart E Mirvis; William Chiu
Journal:  Emerg Radiol       Date:  2012-12-13

5.  Imaging algorithms and CT protocols in trauma patients: survey of Swiss emergency centers.

Authors:  R Hinzpeter; T Boehm; D Boll; C Constantin; F Del Grande; V Fretz; S Leschka; T Ohletz; M Brönnimann; S Schmidt; T Treumann; P-A Poletti; Hatem Alkadhi
Journal:  Eur Radiol       Date:  2016-09-05       Impact factor: 5.315

6.  Topogram-based automated selection of the tube potential and current in thoraco-abdominal trauma CT - a comparison to fixed kV with mAs modulation alone.

Authors:  Claudia Frellesen; Wenzel Stock; J Matthias Kerl; Thomas Lehnert; Julian L Wichmann; Christoph Nau; Emanuel Geiger; Sebastian Wutzler; Martin Beeres; Boris Schulz; Boris Bodelle; Hanns Ackermann; Thomas J Vogl; Ralf W Bauer
Journal:  Eur Radiol       Date:  2014-05-10       Impact factor: 5.315

7.  Influence of arm position and respiration technique during liver examinations on the detectability of mammary lesions.

Authors:  Yasuo Takatsu; Yuko Shimada; Tosiaki Miyati; Toshiki Shiozaki; Katsusuke Kyotani
Journal:  Radiol Phys Technol       Date:  2018-05-14

8.  Emergency CT head and neck imaging: effects of swimmer's position on dose and image quality.

Authors:  Fabian G Mueck; Sebastian Roesch; Lucas Geyer; Michael Scherr; Michael Seidenbusch; Robert Stahl; Zsuzsanna Deak; Stefan Wirth
Journal:  Eur Radiol       Date:  2014-02-15       Impact factor: 5.315

Review 9.  [Update polytrauma and computed tomography in ongoing resuscitation : ABCDE and "diagnose first what kills first"].

Authors:  Alexander Gäble; Julian Hebebrand; Marco Armbruster; Fabian Mück; Maria Berndt; Bernhard Kumle; Ulrich Fink; Stefan Wirth
Journal:  Radiologe       Date:  2020-03       Impact factor: 0.635

10.  Radiologic diagnostic procedures in severely injured patients - is only whole-body multislice computed tomography the answer?

Authors:  Tobias Topp; Rolf Lefering; Caroline L Lopez; Steffen Ruchholtz; Wolfgang Ertel; Christian A Kühne
Journal:  Int J Emerg Med       Date:  2015-02-28
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.