Literature DB >> 29761451

Influence of arm position and respiration technique during liver examinations on the detectability of mammary lesions.

Yasuo Takatsu1,2, Yuko Shimada3, Tosiaki Miyati4, Toshiki Shiozaki3, Katsusuke Kyotani5.   

Abstract

During liver computed tomography (CT), scanning is performed with the raised arm position and an inhalation technique. However, for liver magnetic resonance imaging (MRI), the arms are placed at the sides of the body and an exhalation technique is used. This study was aimed at evaluating the effect that the patient's arm position and respiration technique had on the ability to detect mammary glands in the scan range to discover unexpected mammary lesions during the liver MRI examination. Liver MRI and CT images were compared for 337 female patients. More than half of the mammary glands were included in 97.3% of MRI, but in 4.7% of CT. No mammary lesions were found during CT, whereas seven were found during MRI. The mammary lesions are more likely to be detected when the patient places her arms at the sides of the body and uses the exhalation technique during liver MRI.

Entities:  

Keywords:  Arm position; Liver; Magnetic resonance imaging; Mammary lesions; Respiration technique

Mesh:

Year:  2018        PMID: 29761451     DOI: 10.1007/s12194-018-0463-4

Source DB:  PubMed          Journal:  Radiol Phys Technol        ISSN: 1865-0333


  23 in total

1.  A dynamic analysis of chest wall motions with MRI in healthy young subjects.

Authors:  T Kondo; I Kobayashi; Y Taguchi; Y Ohta; N Yanagimachi
Journal:  Respirology       Date:  2000-03       Impact factor: 6.424

2.  Imaging of metastatic breast cancer: distribution and radiological assessment at presentation.

Authors:  J P Whitlock; A J Evans; L Jackson; S Y Chan; J F Robertson
Journal:  Clin Oncol (R Coll Radiol)       Date:  2001       Impact factor: 4.126

3.  Simple modification of arm position improves B1+ and signal homogeneity in the thoracolumbar spine at 3T.

Authors:  Kinya Ishizaka; Kohsuke Kudo; Kuniaki Harada; Toru Shirai; Taro Fujiwara; Suzuko Aoike; Sayaka Takamori; Hiroki Shirato
Journal:  J Magn Reson Imaging       Date:  2017-05-26       Impact factor: 4.813

4.  Radiation exposure in whole-body computed tomography of multiple trauma patients: bearing devices and patient positioning.

Authors:  Björn Loewenhardt; Michael Buhl; André Gries; Clemens-Alexander Greim; Achim Hellinger; Martin Hessmann; Thomas Rathjen; Michael Reinert; Christoph Manke; Michael Bernhard
Journal:  Injury       Date:  2011-11-04       Impact factor: 2.586

5.  Influence of arm positioning on radiation dose for whole body computed tomography in trauma patients.

Authors:  Jörg Bayer; Gregor Pache; Peter C Strohm; Jörn Zwingmann; Philipp Blanke; Tobias Baumann; Norbert P Südkamp; Thorsten Hammer
Journal:  J Trauma       Date:  2011-04

6.  Breast ptosis. Definition and treatment.

Authors:  P Regnault
Journal:  Clin Plast Surg       Date:  1976-04       Impact factor: 2.017

7.  Measurement of diaphragmatic length during the breathing cycle by dynamic MRI: comparison between healthy adults and patients with an intrathoracic tumor.

Authors:  Christian Plathow; Christian Fink; Sebastian Ley; Michael Puderbach; Monica Eichinger; Astrid Schmähl; Hans-Ulrich Kauczor
Journal:  Eur Radiol       Date:  2004-05-01       Impact factor: 5.315

8.  Is diaphragm motion a good surrogate for liver tumor motion?

Authors:  Juan Yang; Jing Cai; Hongjun Wang; Zheng Chang; Brian G Czito; Mustafa R Bashir; Manisha Palta; Fang-Fang Yin
Journal:  Int J Radiat Oncol Biol Phys       Date:  2014-09-12       Impact factor: 7.038

9.  How does arm positioning of polytraumatized patients in the initial computed tomography (CT) affect image quality and diagnostic accuracy?

Authors:  Johannes Kahn; Ulrich Grupp; Martin Maurer
Journal:  Eur J Radiol       Date:  2013-10-16       Impact factor: 3.528

10.  Breast MRI: guidelines from the European Society of Breast Imaging.

Authors:  R M Mann; C K Kuhl; K Kinkel; C Boetes
Journal:  Eur Radiol       Date:  2008-04-04       Impact factor: 5.315

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.