Evaluation of a Gafchromic EBT2 film dosimetry system for radiotherapy quality assurance.

T Aland1, T Kairn, J Kenny.   

Abstract

This study examines the dosimetric accuracy of Gafchromic EBT2 model radiochromic film for use in radiotherapy quality assurance. In this study, film was scanned using an Epson Perfection V700 flatbed scanner in transmission mode at 75 DPI with the subsequent analysis performed using the red and blue colour channels and ImageJ software. Results of this study suggest that the conversion of film optical density to measured dose should, at present, utilise red channel data only, without application of a blue channel correction to the data. For the batch of film examined here, film uniformity and reproducibility appear to have improved compared with published results using older batches. The orientation of the film on the scanner and the side of the film facing the light source were found to have substantial effects on results. Based on the results of this study, it is possible to recommend the use of EBT2 film in routine quality assurance testing for radiotherapy, in situations where a dose uncertainty of up to 2.8% is acceptable.

Mesh:

Year:  2011        PMID: 21465275     DOI: 10.1007/s13246-011-0072-6

Source DB:  PubMed          Journal:  Australas Phys Eng Sci Med        ISSN: 0158-9938            Impact factor:   1.430


  22 in total

1.  Quality assurance evaluation of spot scanning beam proton therapy with an anthropomorphic prostate phantom.

Authors:  K Iqbal; M Gillin; P A Summers; S Dhanesar; K A Gifford; S A Buzdar
Journal:  Br J Radiol       Date:  2013-09-18       Impact factor: 3.039

2.  Examining credentialing criteria and poor performance indicators for IROC Houston's anthropomorphic head and neck phantom.

Authors:  Mallory E Carson; Andrea Molineu; Paige A Taylor; David S Followill; Francesco C Stingo; Stephen F Kry
Journal:  Med Phys       Date:  2016-12       Impact factor: 4.071

3.  Correction of lateral response artifacts from flatbed scanners for dual-channel radiochromic film dosimetry.

Authors:  Yuichi Akino; Hiroya Shiomi; Fumiaki Isohashi; Osamu Suzuki; Yuji Seo; Keisuke Tamari; Takero Hirata; Hirokazu Mizuno; Kazuhiko Ogawa
Journal:  J Radiat Res       Date:  2021-03-10       Impact factor: 2.724

4.  SBRT/SRS patient-specific QA using GAFchromicTM EBT3 and FilmQATM Pro software.

Authors:  Giuseppe Stella; Nina Cavalli; Elisa Bonanno; Lucia Zirone; Giuseppina Rita Borzì; Martina Pace; Andrea Girlando; Anna M Gueli; Carmelo Marino
Journal:  J Radiosurg SBRT       Date:  2022

5.  Dose measurements in a thorax phantom at 3DCRT breast radiation therapy.

Authors:  Elsa Bifano Pimenta; Luciana Batista Nogueira; Tarcísio Passos Ribeiro de Campos
Journal:  Rep Pract Oncol Radiother       Date:  2021-04-14

6.  Designing and Dosimetry of a Shield for Photon Fields of Radiation Therapy in Oral Cavity Cancer.

Authors:  Keyvan Jabbari; Somayeh Senobari; Mahnaz Roayaei; Masoumeh Rostampour
Journal:  J Med Signals Sens       Date:  2015 Apr-Jun

7.  The use of radiochromic EBT2 film for the quality assurance and dosimetric verification of 3D conformal radiotherapy using Microtek ScanMaker 9800XL flatbed scanner.

Authors:  G S Sim; J H D Wong; K H Ng
Journal:  J Appl Clin Med Phys       Date:  2013-07-08       Impact factor: 2.102

8.  Characterization of the effect of MRI on Gafchromic film dosimetry.

Authors:  Meral L Reyhan; Ting Chen; Miao Zhang
Journal:  J Appl Clin Med Phys       Date:  2015-11-08       Impact factor: 2.102

9.  Homogeneity of GAFCHROMIC EBT2 film among different lot numbers.

Authors:  Hirokazu Mizuno; Yutaka Takahashi; Atsushi Tanaka; Takamitsu Hirayama; Tsuyoshi Yamaguchi; Hiroaki Katou; Keiko Takahara; Yoshiaki Okamoto; Teruki Teshima
Journal:  J Appl Clin Med Phys       Date:  2012-07-05       Impact factor: 2.102

10.  Characterization of MOSkin detector for in vivo skin dose measurement during megavoltage radiotherapy.

Authors:  Wei Loong Jong; Jeannie Hsiu Ding Wong; Ngie Min Ung; Kwan Hoong Ng; Gwo Fuang Ho; Dean L Cutajar; Anatoly B Rosenfeld
Journal:  J Appl Clin Med Phys       Date:  2014-09-08       Impact factor: 2.102

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.