Literature DB >> 21462356

Microfabrication and nanotechnology in stent design.

Adam W Martinez1, Elliot L Chaikof.   

Abstract

Intravascular stents were first introduced in the 1980s as an adjunct to primary angioplasty for management of early complications, including arterial dissection, or treatment of an inadequate technical outcome due to early elastic recoil of the atherosclerotic lesion. Despite the beneficial effects of stenting, persistent high rates of restenosis motivated the design of drug-eluting stents for delivery of agents to limit the proliferative and other inflammatory responses within the vascular wall that contribute to the development of a restenotic lesion. These strategies have yielded a significant reduction in the incidence of restenosis, but challenges remain, including incomplete repair of the endothelium at the site of vascular wall injury that may be associated with a late risk of thrombosis. A failure of vessel wall healing has been attributed primarily to the use of polymeric stent coatings, but the effects of the eluted drug and other material properties or design features of the stent cannot be excluded. Improvements in stent microfabrication, as well as the introduction of alternative materials may help to address those limitations that inhibit stent performance. This review describes the application of novel microfabrication processes and the evolution of new nanotechnologies that hold significant promise in eliminating existing shortcomings of current stent platforms.
Copyright © 2011 John Wiley & Sons, Inc.

Entities:  

Mesh:

Year:  2011        PMID: 21462356      PMCID: PMC3480085          DOI: 10.1002/wnan.123

Source DB:  PubMed          Journal:  Wiley Interdiscip Rev Nanomed Nanobiotechnol        ISSN: 1939-0041


  84 in total

1.  Development of a platform to evaluate and limit in-stent restenosis.

Authors:  C J Elkins; J M Waugh; P G Amabile; H Minamiguchi; M Uy; K Sugimoto; Y S Do; F Ganaha; M K Razavi; M D Dake
Journal:  Tissue Eng       Date:  2002-07

2.  Surface oxidation of NiTi shape memory alloy.

Authors:  G S Firstov; R G Vitchev; H Kumar; B Blanpain; J Van Humbeeck
Journal:  Biomaterials       Date:  2002-12       Impact factor: 12.479

3.  Evaluation of the Medtronic (Driver) cobalt-chromium alloy coronary stent system.

Authors:  Michael H Sketch; Michael Ball; Barry Rutherford; Jeffrey J Popma; Catherine Russell; Dean J Kereiakes
Journal:  Am J Cardiol       Date:  2005-01-01       Impact factor: 2.778

4.  Layer-by-layer assembly of cationic lipid and plasmid DNA onto gold surface for stent-assisted gene transfer.

Authors:  Fumio Yamauchi; Yuichi Koyamatsu; Koichi Kato; Hiroo Iwata
Journal:  Biomaterials       Date:  2006-02-20       Impact factor: 12.479

5.  PLA stereocopolymers as sources of bioresorbable stents: preliminary investigation in rabbit.

Authors:  Antoine Lafont; Suming Li; Henri Garreau; Frederic Cornhill; Michel Vert
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2006-05       Impact factor: 3.368

6.  The covalent immobilization of heparin to pulsed-plasma polymeric allylamine films on 316L stainless steel and the resulting effects on hemocompatibility.

Authors:  Zhilu Yang; Jin Wang; Rifang Luo; Manfred F Maitz; Fengjuan Jing; Hong Sun; Nan Huang
Journal:  Biomaterials       Date:  2010-03       Impact factor: 12.479

7.  The use of alkanethiol self-assembled monolayers on 316L stainless steel for coronary artery stent nanomedicine applications: an oxidative and in vitro stability study.

Authors:  Anil Mahapatro; Dave M Johnson; Devang N Patel; Marc D Feldman; Arturo A Ayon; C Mauli Agrawal
Journal:  Nanomedicine       Date:  2006-09       Impact factor: 5.307

8.  The first report of late stent thrombosis leading to acute myocardial infarction in patient receiving the new endothelial progenitor cell capture stent.

Authors:  Marco L Rossi; Dennis Zavalloni; Gabriele L Gasparini; Ruggiero Mango; Guido Belli; Patrizia Presbitero
Journal:  Int J Cardiol       Date:  2009-01-09       Impact factor: 4.164

9.  Randomized trial of three rapamycin-eluting stents with different coating strategies for the reduction of coronary restenosis.

Authors:  Julinda Mehilli; Robert A Byrne; Anna Wieczorek; Raisuke Iijima; Stefanie Schulz; Olga Bruskina; Jürgen Pache; Rainer Wessely; Albert Schömig; Adnan Kastrati
Journal:  Eur Heart J       Date:  2008-06-11       Impact factor: 29.983

Review 10.  Novel thromboresistant materials.

Authors:  Sumanas W Jordan; Elliot L Chaikof
Journal:  J Vasc Surg       Date:  2007-06       Impact factor: 4.268

View more
  8 in total

Review 1.  Restenosis after PCI. Part 2: prevention and therapy.

Authors:  J Wouter Jukema; Tarek A N Ahmed; Jeffrey J W Verschuren; Paul H A Quax
Journal:  Nat Rev Cardiol       Date:  2011-10-11       Impact factor: 32.419

Review 2.  Perspectives and opportunities for nanomedicine in the management of atherosclerosis.

Authors:  Mark E Lobatto; Valentin Fuster; Zahi A Fayad; Willem J M Mulder
Journal:  Nat Rev Drug Discov       Date:  2011-10-21       Impact factor: 84.694

3.  Endothelial retention and phenotype on carbonized cardiovascular implant surfaces.

Authors:  Christopher M Frendl; Scott M Tucker; Nadeem A Khan; Mandy B Esch; Shrinidhi Kanduru; Thong M Cao; Andrés J García; Michael R King; Jonathan T Butcher
Journal:  Biomaterials       Date:  2014-06-20       Impact factor: 12.479

Review 4.  An insight into biomimetic 4D printing.

Authors:  Nand Jee Kanu; Eva Gupta; Umesh Kumar Vates; Gyanendra Kumar Singh
Journal:  RSC Adv       Date:  2019-11-22       Impact factor: 4.036

Review 5.  Surface engineering at the nanoscale: A way forward to improve coronary stent efficacy.

Authors:  Aleena Mary Cherian; Shantikumar V Nair; Vijayakumar Maniyal; Deepthy Menon
Journal:  APL Bioeng       Date:  2021-06-01

6.  Shape Memory Polymers Containing Higher Acrylate Content Display Increased Endothelial Cell Attachment.

Authors:  Tina Govindarajan; Robin Shandas
Journal:  Polymers (Basel)       Date:  2017-11-03       Impact factor: 4.329

Review 7.  Nanoparticle drug- and gene-eluting stents for the prevention and treatment of coronary restenosis.

Authors:  Rui-Xing Yin; De-Zhai Yang; Jin-Zhen Wu
Journal:  Theranostics       Date:  2014-01-08       Impact factor: 11.556

Review 8.  Bioresorbable Polymeric Scaffold in Cardiovascular Applications.

Authors:  Daniel Wee Yee Toong; Han Wei Toh; Jaryl Chen Koon Ng; Philip En Hou Wong; Hwa Liang Leo; Subramanian Venkatraman; Lay Poh Tan; Hui Ying Ang; Yingying Huang
Journal:  Int J Mol Sci       Date:  2020-05-13       Impact factor: 5.923

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.