Literature DB >> 21460757

Visual acuity with simulated and real astigmatic defocus.

Arne Ohlendorf1, Juan Tabernero, Frank Schaeffel.   

Abstract

PURPOSE: To compare the effects of "simulated" and "real" spherical and astigmatic defocus on visual acuity (VA).
METHODS: VA was determined with letter charts that were blurred by calculated spherical or astigmatic defocus (simulated defocus) or were seen through spherical or astigmatic trial lenses (real defocus). Defocus was simulated using ZEMAX and the Liou-Brennan eye model. Nine subjects participated [mean age, 27.2 ± 1.8 years; logarithm of the minimum angle of resolution (logMAR), -0.1]. Three different experiments were conducted in which VA was reduced by 20% (logMAR 0.0), 50% (logMAR 0.2), or 75% (logMAR 0.5) by either (1) imposing positive spherical defocus, (2) imposing positive and negative astigmatic defocus in three axes (0, 45, and 90°), and (3) imposing cross-cylinder defocus in the same three axes as in (2).
RESULTS: Experiment (1): there were only minor differences in VA with simulated and real positive spherical defocus. Experiment (2): simulated astigmatic defocus reduced VA twice as much as real astigmatic defocus in all tested axes (p < 0.01 in all cases). Experiment (3): simulated cross-cylinder defocus reduced VA much more than real cross-cylinder defocus (p < 0.01 in all cases), similarly for all three tested axes.
CONCLUSIONS: The visual system appears more tolerant against "real" spherical, astigmatic, and cross-cylinder defocus than against "simulated" blur. Possible reasons could be (1) limitations in the modeling procedures to simulate defocus, (2) higher ocular aberrations, and (3) fluctuations of accommodation. However, the two optical explanations (2) and (3) cannot account for the magnitude of the effect, and (1) was carefully analyzed. It is proposed that something may be special about the visual processing of real astigmatic and cross-cylinder defocus-because they have less effect on VA than simulations predict.

Entities:  

Mesh:

Year:  2011        PMID: 21460757     DOI: 10.1097/OPX.0b013e31821281bc

Source DB:  PubMed          Journal:  Optom Vis Sci        ISSN: 1040-5488            Impact factor:   1.973


  8 in total

Review 1.  Advances in understanding the molecular basis of the first steps in color vision.

Authors:  Lukas Hofmann; Krzysztof Palczewski
Journal:  Prog Retin Eye Res       Date:  2015-07-15       Impact factor: 21.198

2.  Adapting to blur produced by ocular high-order aberrations.

Authors:  Lucie Sawides; Pablo de Gracia; Carlos Dorronsoro; Michael Webster; Susana Marcos
Journal:  J Vis       Date:  2011-06-28       Impact factor: 2.240

3.  Influence of simple myopic against-the-rule and with-the-rule astigmatism on visual acuity in eyes with monofocal intraocular lenses.

Authors:  Toshiya Yamamoto; Takahiro Hiraoka; Simone Beheregaray; Tetsuro Oshika
Journal:  Jpn J Ophthalmol       Date:  2014-07-08       Impact factor: 2.447

4.  Influence of different types of astigmatism on visual acuity.

Authors:  Laura Remón; Juan A Monsoriu; Walter D Furlan
Journal:  J Optom       Date:  2016-09-14

5.  The effect of astigmatic axis on visual acuity measured with different alphabets in Roman alphabet readers.

Authors:  Pedro M Serra; Michael J Cox; Catharine M Chisholm
Journal:  Clin Optom (Auckl)       Date:  2018-08-06

6.  Effect of cylinder power and axis changes on vision in astigmatic participants.

Authors:  J Sha; C Fedtke; D Tilia; N Yeotikar; M Jong; J Diec; V Thomas; R C Bakaraju
Journal:  Clin Optom (Auckl)       Date:  2019-03-19

7.  Matching convolved images to optically blurred images on the retina.

Authors:  Sara Aissati; Clara Benedi-Garcia; Maria Vinas; Alberto de Castro; Susana Marcos
Journal:  J Vis       Date:  2022-02-01       Impact factor: 2.240

8.  Eyelid squinting improves near vision in against-the-rule and distance vision in with-the-rule astigmatism in pseudophakic eyes: an eye model experimental study.

Authors:  Jay Won Rhim; Youngsub Eom; Seo Yeon Park; Su-Yeon Kang; Jong Suk Song; Hyo Myung Kim
Journal:  BMC Ophthalmol       Date:  2020-01-02       Impact factor: 2.209

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.