A multiple points method for 4D CT image sorting.

Chiara Gianoli1, Marco Riboldi, Maria Francesca Spadea, Laura Lavinia Travaini, Mahila Ferrari, Riccardo Mei, Roberto Orecchia, Guido Baroni.   

Abstract

PURPOSE: Artifacts affect 4D CT images due to breathing irregularities or incorrect breathing phase identification. The purpose of this study is the reduction of artifacts in sorted 4D CT images. The assumption is that the use of multiple respiratory related signals may reduce uncertainties and increase robustness in breathing phase identification.
METHODS: Multiple respiratory related signals were provided by infrared 3D localization of a configuration of markers placed on the thoracoabdominal surface. Multidimensional K-means clustering was used for retrospective 4D CT image sorting, which was based on multiple marker variables, in order to identify clusters representing different breathing phases. The proposed technique was tested on computational simulations, phantom experimental acquisitions, and clinical data coming from two patients. Computational simulations provided a controlled and noise-free condition for testing the clustering technique on regular and irregular breathing signals, including baseline drift, time variant amplitude, time variant frequency, and end-expiration plateau. Specific attention was given to cluster initialization. Phantom experiments involved two moving phantoms fitted with multiple markers. Phantoms underwent 4D CT acquisition while performing controlled rigid motion patterns and featuring end-expiration plateau. Breathing cycle period and plateau duration were controlled by means of weights leaned upon the phantom during repeated 4D CT scans. The implemented sorting technique was applied to clinical 4D CT scans acquired on two patients and results were compared to conventional sorting methods.
RESULTS: For computational simulations and phantom studies, the performance of the multidimensional clustering technique was evaluated by measuring the repeatability in identifying the breathing phase among adjacent couch positions and the uniformity in sampling the breathing cycle. When breathing irregularities were present, the clustering technique consistently improved breathing phase identification with respect to conventional sorting methods based on monodimensional signals. In patient studies, a qualitative comparison was performed between corresponding breathing phases of 4D CT images obtained by conventional sorting methods and by the described clustering technique. Artifact reduction was clearly observable on both data set especially in the lower lung region.
CONCLUSIONS: The implemented multiple point method demonstrated the ability to reduce artifacts in 4D CT imaging. Further optimization and development are needed to make the most of the availability of multiple respiratory related variables and to extend the method to 4D CT-PET hybrid scan.

Entities:  

Mesh:

Year:  2011        PMID: 21452703     DOI: 10.1118/1.3538921

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  15 in total

1.  Reduction of irregular breathing artifacts in respiration-correlated CT images using a respiratory motion model.

Authors:  Agung Hertanto; Qinghui Zhang; Yu-Chi Hu; Oleksandr Dzyubak; Andreas Rimner; Gig S Mageras
Journal:  Med Phys       Date:  2012-06       Impact factor: 4.071

2.  Prediction error and required internal margin provided for irregular respiratory movements: a phantom study.

Authors:  Nobuyoshi Fukumitsu; Haruko Numajiri; Kayoko Ohnishi; Masashi Mizumoto; Teruhito Aihara; Hitoshi Ishikawa; Toshiyuki Okumura; Koji Tsuboi; Toshiyuki Terunuma; Takeji Sakae; Hideyuki Sakurai
Journal:  Jpn J Radiol       Date:  2015-04-16       Impact factor: 2.374

3.  A tool for validating MRI-guided strategies: a digital breathing CT/MRI phantom of the abdominal site.

Authors:  Chiara Paganelli; Paul Summers; Chiara Gianoli; Massimo Bellomi; Guido Baroni; Marco Riboldi
Journal:  Med Biol Eng Comput       Date:  2017-04-08       Impact factor: 2.602

Review 4.  Improving radiotherapy planning, delivery accuracy, and normal tissue sparing using cutting edge technologies.

Authors:  Carri K Glide-Hurst; Indrin J Chetty
Journal:  J Thorac Dis       Date:  2014-04       Impact factor: 2.895

5.  Real-time prediction of tumor motion using a dynamic neural network.

Authors:  Majid Mafi; Saeed Montazeri Moghadam
Journal:  Med Biol Eng Comput       Date:  2020-01-08       Impact factor: 2.602

6.  Rapid estimation of 4DCT motion-artifact severity based on 1D breathing-surrogate periodicity.

Authors:  Guang Li; Marshall Caraveo; Jie Wei; Andreas Rimner; Abraham J Wu; Karyn A Goodman; Ellen Yorke
Journal:  Med Phys       Date:  2014-11       Impact factor: 4.071

Review 7.  Advances in 4D radiation therapy for managing respiration: part I - 4D imaging.

Authors:  Geoffrey D Hugo; Mihaela Rosu
Journal:  Z Med Phys       Date:  2012-07-10       Impact factor: 4.820

8.  Patient specific respiratory motion modeling using a 3D patient's external surface.

Authors:  Hadi Fayad; Tinsu Pan; Olivier Pradier; Dimitris Visvikis
Journal:  Med Phys       Date:  2012-06       Impact factor: 4.071

9.  T2-weighted four dimensional magnetic resonance imaging with result-driven phase sorting.

Authors:  Yilin Liu; Fang-Fang Yin; Brian G Czito; Mustafa R Bashir; Jing Cai
Journal:  Med Phys       Date:  2015-08       Impact factor: 4.071

Review 10.  Advances in 4D treatment planning for scanned particle beam therapy - report of dedicated workshops.

Authors:  Christoph Bert; Christian Graeff; Marco Riboldi; Simeon Nill; Guido Baroni; Antje-Christin Knopf
Journal:  Technol Cancer Res Treat       Date:  2013-12-17
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.