PURPOSE: Respiratory motion modeling of both tumor and surrounding tissues is a key element in minimizing errors and uncertainties in radiation therapy. Different continuous motion models have been previously developed. However, most of these models are based on the use of parameters such as amplitude and phase extracted from 1D external respiratory signal. A potentially reduced correlation between the internal structures (tumor and healthy organs) and the corresponding external surrogates obtained from such 1D respiratory signal is a limitation of these models. The objective of this work is to describe a continuous patient specific respiratory motion model, accounting for the irregular nature of respiratory signals, using patient external surface information as surrogate measures rather than a 1D respiratory signal. METHODS: Ten patients were used in this study having each one 4D CT series, a synchronized RPM signal and patient surfaces extracted from the 4D CT volumes using a threshold based segmentation algorithm. A patient specific model based on the use of principal component analysis was subsequently constructed. This model relates the internal motion described by deformation matrices and the external motion characterized by the amplitude and the phase of the respiratory signal in the case of the RPM or using specific regions of interest (ROI) in the case of the patients' external surface utilization. The capability of the different models considered to handle the irregular nature of respiration was assessed using two repeated 4D CT acquisitions (in two patients) and static CT images acquired at extreme respiration conditions (end of inspiration and expiration) for one patient. RESULTS: Both quantitative and qualitative parameters covering local and global measures, including an expert observer study, were used to assess and compare the performance of the different motion estimation models considered. Results indicate that using surface information [correlation coefficient (CC): 0.998 ± 0.0006 and model error (ME): 1.35 ± 0.21 mm] is superior to the use of both motion phase and amplitude extracted from a 1D respiratory signal (CC and ME of 0.971 ± 0.02 and 1.64 ± 0.28 mm). The difference in performance was more substantial compared to the use of only one parameter (phase or amplitude) used in the motion model construction. Similarly, the patient surface based model was better in estimating the motion in the repeated 4D CT acquisitions and those CT images acquired at the full inspiration (FI) and the full expiration (FE). Once more, within this context the use of both amplitude and phase in the model building was substantially more robust than the use of phase or amplitude only. CONCLUSIONS: The present study demonstrates the potential of using external patient surfaces for the construction of patient specific respiratory motion models. Such information can be obtained using different devices currently available. The use of external surface information led to the best performance in estimating internal structure motion. On the other hand, the use of both amplitude and phase parameters derived from an 1D respiration signal led to largely superior model performance relative to the use of only one of these two parameters in the model building process.
PURPOSE: Respiratory motion modeling of both tumor and surrounding tissues is a key element in minimizing errors and uncertainties in radiation therapy. Different continuous motion models have been previously developed. However, most of these models are based on the use of parameters such as amplitude and phase extracted from 1D external respiratory signal. A potentially reduced correlation between the internal structures (tumor and healthy organs) and the corresponding external surrogates obtained from such 1D respiratory signal is a limitation of these models. The objective of this work is to describe a continuous patient specific respiratory motion model, accounting for the irregular nature of respiratory signals, using patient external surface information as surrogate measures rather than a 1D respiratory signal. METHODS: Ten patients were used in this study having each one 4D CT series, a synchronized RPM signal and patient surfaces extracted from the 4D CT volumes using a threshold based segmentation algorithm. A patient specific model based on the use of principal component analysis was subsequently constructed. This model relates the internal motion described by deformation matrices and the external motion characterized by the amplitude and the phase of the respiratory signal in the case of the RPM or using specific regions of interest (ROI) in the case of the patients' external surface utilization. The capability of the different models considered to handle the irregular nature of respiration was assessed using two repeated 4D CT acquisitions (in two patients) and static CT images acquired at extreme respiration conditions (end of inspiration and expiration) for one patient. RESULTS: Both quantitative and qualitative parameters covering local and global measures, including an expert observer study, were used to assess and compare the performance of the different motion estimation models considered. Results indicate that using surface information [correlation coefficient (CC): 0.998 ± 0.0006 and model error (ME): 1.35 ± 0.21 mm] is superior to the use of both motion phase and amplitude extracted from a 1D respiratory signal (CC and ME of 0.971 ± 0.02 and 1.64 ± 0.28 mm). The difference in performance was more substantial compared to the use of only one parameter (phase or amplitude) used in the motion model construction. Similarly, the patient surface based model was better in estimating the motion in the repeated 4D CT acquisitions and those CT images acquired at the full inspiration (FI) and the full expiration (FE). Once more, within this context the use of both amplitude and phase in the model building was substantially more robust than the use of phase or amplitude only. CONCLUSIONS: The present study demonstrates the potential of using external patient surfaces for the construction of patient specific respiratory motion models. Such information can be obtained using different devices currently available. The use of external surface information led to the best performance in estimating internal structure motion. On the other hand, the use of both amplitude and phase parameters derived from an 1D respiration signal led to largely superior model performance relative to the use of only one of these two parameters in the model building process.
Authors: M J Ledesma-Carbayo; P Mahía-Casado; A Santos; E Pérez-David; M A García-Fernández; M Desco Journal: Ultrasound Med Biol Date: 2006-04 Impact factor: 2.998
Authors: Keith R Britton; George Starkschall; Susan L Tucker; Tinsu Pan; Christopher Nelson; Joe Y Chang; James D Cox; Radhe Mohan; Ritsuko Komaki Journal: Int J Radiat Oncol Biol Phys Date: 2007-03-26 Impact factor: 7.038
Authors: Jamie R McClelland; Jane M Blackall; Ségolène Tarte; Adam C Chandler; Simon Hughes; Shahreen Ahmad; David B Landau; David J Hawkes Journal: Med Phys Date: 2006-09 Impact factor: 4.071
Authors: John R van Sörnsen de Koste; Frank J Lagerwaard; Margriet R J Nijssen-Visser; Wilfried J Graveland; Suresh Senan Journal: Int J Radiat Oncol Biol Phys Date: 2003-06-01 Impact factor: 7.038
Authors: Gig S Mageras; Alex Pevsner; Ellen D Yorke; Kenneth E Rosenzweig; Eric C Ford; Agung Hertanto; Steven M Larson; D Michael Lovelock; Yusuf E Erdi; Sadek A Nehmeh; John L Humm; C Clifton Ling Journal: Int J Radiat Oncol Biol Phys Date: 2004-11-01 Impact factor: 7.038
Authors: Michael A King; Joyoni Dey; Karen Johnson; Paul Dasari; Joyeeta M Mukherjee; Joseph E McNamara; Arda Konik; Cliff Lindsay; Shaokuan Zheng; Dennis Coughlin Journal: Med Phys Date: 2013-11 Impact factor: 4.071
Authors: Paul K R Dasari; Mohammed Salman Shazeeb; Arda Könik; Clifford Lindsay; Joyeeta M Mukherjee; Karen L Johnson; Michael A King Journal: Med Phys Date: 2014-11 Impact factor: 4.071
Authors: Matthew J Nyflot; Tzu-Cheng Lee; Adam M Alessio; Scott D Wollenweber; Charles W Stearns; Stephen R Bowen; Paul E Kinahan Journal: Med Phys Date: 2015-01 Impact factor: 4.071
Authors: Marc Garbey; Toan B Nguyen; Albert Y Huang; Vid Fikfak; Brian J Dunkin Journal: Int J Comput Assist Radiol Surg Date: 2017-08-31 Impact factor: 2.924
Authors: Bruno Madore; Gabriela Belsley; Cheng-Chieh Cheng; Frank Preiswerk; Marie Foley Kijewski; Pei-Hsin Wu; Laurel B Martell; Josien P W Pluim; Marcelo Di Carli; Stephen C Moore Journal: Phys Med Biol Date: 2022-01-19 Impact factor: 4.174
Authors: Paul Dasari; Karen Johnson; Joyoni Dey; Clifford Lindsay; Mohammed S Shazeeb; Joyeeta Mitra Mukherjee; Shaokuan Zheng; Michael A King Journal: IEEE Trans Nucl Sci Date: 2014-02-06 Impact factor: 1.679
Authors: D Caleb Rucker; Yifei Wu; Logan W Clements; Janet E Ondrake; Thomas S Pheiffer; Amber L Simpson; William R Jarnagin; Michael I Miga Journal: IEEE Trans Med Imaging Date: 2013-09-20 Impact factor: 10.048