Literature DB >> 21451795

Capsule endoscopy in patients with cardiac pacemakers and implantable cardioverter-defibrillators - a retrospective multicenter investigation.

Dirk Bandorski1, Erich Lotterer, Dirk Hartmann, Ralf Jakobs, Martin Brück, Reinhard Hoeltgen, Marcus Wieczorek, Alexander Brock, Thomas de Rossi, Martin Keuchel.   

Abstract

BACKGROUND & AIMS: Capsule endoscopy (CE) is an established tool for the investigation of the small intestine. The Food and Drug Administration, Given Imaging and Olympus have not recommended the use of capsule endoscopy in patients with cardiac pacemakers and implantable cardioverter defibrillators (ICDs). The aim of this retrospective study was to investigate the safety of capsule endoscopy systems (Given Imaging and Olympus) when applied in patients with different types of pacemakers/ICDs in vivo.
METHODS: A standardized questionnaire was sent to high volume centers in Germany and in Austria. The questionnaire covered the age and gender of the examined patients, indication of CE, brand and type of CE, brand and model of pacemaker/ICD, check of the devices before and after CE, monitoring during CE, possible interference between CE and cardiac pacemakers/ICDs and possible adverse events during CE.
RESULTS: Data from 62 patients were retrieved for this study. Capsules used were Given Imaging (n=58; M2A, M2Aplus, PillCam SB2), Olympus EndoCapsule (n=3), Given PillCam Colon (n=1). The collective included patients with pacemakers/ICDS from seven brands (Biotronik, Medtronic, St. Jude Medical, Guidant, Boston Scientific, Ela Sorin, Vitatron) with a total of 19/8 (pacemaker/ICD) different types. In two patients interference between capsule endoscopy and telemetry (loss of images/gaps in video) was recorded. None of the cardiac pacemakers or ICDs was impaired in function. No clinically evident event was observed in any of these patients.
CONCLUSIONS: Clinical use of these CE types is safe in patients with cardiac pacemakers and ICDs. Interference can occur between CE and ECG-telemetry leading to loss of images or impaired quality of video.

Entities:  

Mesh:

Year:  2011        PMID: 21451795

Source DB:  PubMed          Journal:  J Gastrointestin Liver Dis        ISSN: 1841-8724            Impact factor:   2.008


  14 in total

1.  Safety of capsule endoscopy using human body communication in patients with cardiac devices.

Authors:  Joo Won Chung; Hye Jin Hwang; Moon Jae Chung; Jeong Youp Park; Hui-Nam Pak; Si Young Song
Journal:  Dig Dis Sci       Date:  2012-02-07       Impact factor: 3.199

Review 2.  New vision in video capsule endoscopy: current status and future directions.

Authors:  Laurel R Fisher; William L Hasler
Journal:  Nat Rev Gastroenterol Hepatol       Date:  2012-05-08       Impact factor: 46.802

Review 3.  Video capsule endoscopy: perspectives of a revolutionary technique.

Authors:  Simon Bouchard; Mostafa Ibrahim; Andre Van Gossum
Journal:  World J Gastroenterol       Date:  2014-12-14       Impact factor: 5.742

4.  Small bowel capsule endoscopy in patients with cardiac pacemakers and implantable cardioverter defibrillators: Outcome analysis using telemetry review.

Authors:  Justin R Cuschieri; Mohammed N Osman; Richard Ck Wong; Amitabh Chak; Gerard A Isenberg
Journal:  World J Gastrointest Endosc       Date:  2012-03-16

5.  Lack of interference between small bowel capsule endoscopy and implantable cardiac defibrillators: an 'in vivo' electrophysiological study.

Authors:  Dario Moneghini; Alessandro Lipari; Guido Missale; Luigi Minelli; Gianpaolo Cengia; Luca Bontempi; Antonio Curnis; Renzo Cestari
Journal:  United European Gastroenterol J       Date:  2015-09-24       Impact factor: 4.623

6.  A look into the small bowel in Crohn's disease.

Authors:  Soo Jung Park; Won Ho Kim
Journal:  Clin Endosc       Date:  2012-08-22

7.  Capsule endoscopy in patients with cardiac pacemakers, implantable cardioverter defibrillators, and left heart devices: a review of the current literature.

Authors:  Dirk Bandorski; Martin Keuchel; Martin Brück; Reinhard Hoeltgen; Marcus Wieczorek; Ralf Jakobs
Journal:  Diagn Ther Endosc       Date:  2011-04-27

8.  Capsule Endoscopy in Patients with Cardiac Pacemakers and Implantable Cardioverter Defibrillators: (Re)evaluation of the Current State in Germany, Austria, and Switzerland 2010.

Authors:  Dirk Bandorski; Ralf Jakobs; Martin Brück; Reinhard Hoeltgen; Marcus Wieczorek; Martin Keuchel
Journal:  Gastroenterol Res Pract       Date:  2011-12-29       Impact factor: 2.260

9.  Capsule Endoscopy in Patients with Implantable Electromedical Devices is Safe.

Authors:  Lucinda A Harris; Stephanie L Hansel; Elizabeth Rajan; Komandoor Srivathsan; Robert Rea; Michael D Crowell; David E Fleischer; Shabana F Pasha; Suryakanth R Gurudu; Russell I Heigh; Arthur D Shiff; Janice K Post; Jonathan A Leighton
Journal:  Gastroenterol Res Pract       Date:  2013-04-03       Impact factor: 2.260

10.  Clinical use of capsule endoscopy in a patient with cardiac pacemaker.

Authors:  Osman Ersoy; Ebru Akin; Aylin Demirezer
Journal:  Saudi J Gastroenterol       Date:  2013 Sep-Oct       Impact factor: 2.485